Araştırma Makalesi
BibTex RIS Kaynak Göster

Current-Mode Rail-to Rail Instrumentation Amplifier for General Purpose Instrumentation Applications

Yıl 2016, Special Issue (2016), 363 - 367, 01.12.2016
https://doi.org/10.18100/ijamec.280497

Öz

 Instrumentation amplifiers are used extensively in
bio-potential reading, industrial sensor applications, Wheatstone bridge
amplifiers etc. In this work, a high input common-mode range instrumentation
amplifier is presented. The amplifier is composed of two second generation
current conveyors (CCII+) with common-mode input range close to supply swings
and a differential difference current conveyor (DDCC) at the second stage with
high voltage swing at the output. Also an optional DC servo loop is employed as
a feedback to second stage for the removal of any possible DC offset voltage at
the output which can be used for AC coupled applications. The simple design
strategy with high input common-mode range and nearly rail-to-rail output stage
together with increased bandwidth advantage of current-mode approach makes the
proposed implementation desirable for many of the general purpose
instrumentation applications. The design is made using 0.35μm AMS technology
with 3V supply voltage. The operation is verified by HSPICE simulations.

Kaynakça

  • [1] S. Franco, Design with Operational Amplifiers and Analog Integrated Circuits,2nd Ed., McGraw Hill, 1997.
  • [2] K. Koli, “CMRR enhancement techniques for current-mode instrumentation amplifiers”, IEEE Trans. on Circuits and Systems I, pp. 622-632, Vol.47, No.5, May 2000.
  • [3] W. J. Su, F. J. Lidgey, “Common-mode rejection ratio in current-mode instrumentation amplifiers”, Analog Integrated Circuits and Signal Processing, Vol. 7, Issue 3, pp 257-260, May 1995.
  • [4] C. Toumazou, F. Lidgey, “Novel current-mode instrumentation amplifier”, Electron. Lett., Vol. 25, pp. 228-230, Feb. 1989.
  • [5] S. J. G. Gift, “An Enhanced current-mode instrumentation amplifier”, IEEE Trans. on Inst. and Meas., Vol. 50, No. 1, pp. 85-88, Feb. 2001.
  • [6] S. J.G. Gift, B. Maundy, F Muddeen, "High-performance current-mode instrumentation amplifier circuit", Int. Jour. of Electronics, Vol. 94, No.11, pp. 1015-1024, Nov. 2007.
  • [7] A. Khan, M. A. Turaigi, M.A. Al-Ela , “An Improved Current-Mode Instrumentation Amplifier with Bandwidth Independent of Gain”, IEEE Trans. on Inst. and Meas., Vol.44, No.4, 1995.
  • [8] A W. Chiu, S. I. Liu, H. W. Tsao, J. J. Chen, "CMOS differential difference current conveyors and their applications", IEE Proc. Circuits Devices Syst., Vol. 143, No. 2, April 1996.
  • [9] B. Razavi, Fundamentals of Microelectronics, Wiley, 2008.
  • [10] G.Ferri, N.Guerrini, Low-voltage low-power CMOS current-conveyors, Kluwer Academic Publisher, Boston, 2003.
  • [11] C.Falconi, G.Ferri, V.Stornelli, A. De Marcellis, A.DAmico, D.Mazzieri, “Current Mode, High Accuracy, High Precision CMOS Amplifiers”, IEEE Transactions on Circuits and Systems II, vol.55 n.5, May 2008, pp.394-398.
  • [12] D. M. Das, M. S. Baghini, D. K. Sharma, “Design Considerations for High-CMRR Low-Power Current Mode Instrumentation Amplifier for Biomedical Data Acquisition Systems”, ICECS 2014, pp. 251-254, Dec. 2014.
  • [13] W. J. Su, E. J. Lidgey, “Common-mode rejection ratio in current-mode instrumentation amplifiers”, Analog Integr. Circ. Sig. Process., Vol. 7, pp: 257-260, 1995.
  • [14] C. A. Prior, C. R. Rodrigues, A. L. Aita, J. B. Martins, F. C. Vieira, “Design of an integrated low power high CMRR instrumentation amplifier for biomedical applications”, Analog Integr. Circ. Sig. Process., Vol. 57, pp. 11-17, 2008.
  • [15] P. Bruschi, F. D. Cesta, M. Piotto, R. Simmarano, “A very compact CMOS instrumentation amplifier with nearly rail-to-rail input common mode range”, ICECS 2014, pp. 323-326, Dec. 2014.
  • [16] D. M. Das, M. S. Baghini, D. K. Sharma, “Design Considerations for High-CMRR Low-Power Current Mode Instrumentation Amplifier for Biomedical Data Acquisition Systems”, ICECS 2014, pp. 251-254, Dec. 2014.
Yıl 2016, Special Issue (2016), 363 - 367, 01.12.2016
https://doi.org/10.18100/ijamec.280497

Öz

Kaynakça

  • [1] S. Franco, Design with Operational Amplifiers and Analog Integrated Circuits,2nd Ed., McGraw Hill, 1997.
  • [2] K. Koli, “CMRR enhancement techniques for current-mode instrumentation amplifiers”, IEEE Trans. on Circuits and Systems I, pp. 622-632, Vol.47, No.5, May 2000.
  • [3] W. J. Su, F. J. Lidgey, “Common-mode rejection ratio in current-mode instrumentation amplifiers”, Analog Integrated Circuits and Signal Processing, Vol. 7, Issue 3, pp 257-260, May 1995.
  • [4] C. Toumazou, F. Lidgey, “Novel current-mode instrumentation amplifier”, Electron. Lett., Vol. 25, pp. 228-230, Feb. 1989.
  • [5] S. J. G. Gift, “An Enhanced current-mode instrumentation amplifier”, IEEE Trans. on Inst. and Meas., Vol. 50, No. 1, pp. 85-88, Feb. 2001.
  • [6] S. J.G. Gift, B. Maundy, F Muddeen, "High-performance current-mode instrumentation amplifier circuit", Int. Jour. of Electronics, Vol. 94, No.11, pp. 1015-1024, Nov. 2007.
  • [7] A. Khan, M. A. Turaigi, M.A. Al-Ela , “An Improved Current-Mode Instrumentation Amplifier with Bandwidth Independent of Gain”, IEEE Trans. on Inst. and Meas., Vol.44, No.4, 1995.
  • [8] A W. Chiu, S. I. Liu, H. W. Tsao, J. J. Chen, "CMOS differential difference current conveyors and their applications", IEE Proc. Circuits Devices Syst., Vol. 143, No. 2, April 1996.
  • [9] B. Razavi, Fundamentals of Microelectronics, Wiley, 2008.
  • [10] G.Ferri, N.Guerrini, Low-voltage low-power CMOS current-conveyors, Kluwer Academic Publisher, Boston, 2003.
  • [11] C.Falconi, G.Ferri, V.Stornelli, A. De Marcellis, A.DAmico, D.Mazzieri, “Current Mode, High Accuracy, High Precision CMOS Amplifiers”, IEEE Transactions on Circuits and Systems II, vol.55 n.5, May 2008, pp.394-398.
  • [12] D. M. Das, M. S. Baghini, D. K. Sharma, “Design Considerations for High-CMRR Low-Power Current Mode Instrumentation Amplifier for Biomedical Data Acquisition Systems”, ICECS 2014, pp. 251-254, Dec. 2014.
  • [13] W. J. Su, E. J. Lidgey, “Common-mode rejection ratio in current-mode instrumentation amplifiers”, Analog Integr. Circ. Sig. Process., Vol. 7, pp: 257-260, 1995.
  • [14] C. A. Prior, C. R. Rodrigues, A. L. Aita, J. B. Martins, F. C. Vieira, “Design of an integrated low power high CMRR instrumentation amplifier for biomedical applications”, Analog Integr. Circ. Sig. Process., Vol. 57, pp. 11-17, 2008.
  • [15] P. Bruschi, F. D. Cesta, M. Piotto, R. Simmarano, “A very compact CMOS instrumentation amplifier with nearly rail-to-rail input common mode range”, ICECS 2014, pp. 323-326, Dec. 2014.
  • [16] D. M. Das, M. S. Baghini, D. K. Sharma, “Design Considerations for High-CMRR Low-Power Current Mode Instrumentation Amplifier for Biomedical Data Acquisition Systems”, ICECS 2014, pp. 251-254, Dec. 2014.
Toplam 16 adet kaynakça vardır.

Ayrıntılar

Konular Mühendislik
Bölüm Research Article
Yazarlar

Uğur Çini

Yayımlanma Tarihi 1 Aralık 2016
Yayımlandığı Sayı Yıl 2016 Special Issue (2016)

Kaynak Göster

APA Çini, U. (2016). Current-Mode Rail-to Rail Instrumentation Amplifier for General Purpose Instrumentation Applications. International Journal of Applied Mathematics Electronics and Computers(Special Issue-1), 363-367. https://doi.org/10.18100/ijamec.280497
AMA Çini U. Current-Mode Rail-to Rail Instrumentation Amplifier for General Purpose Instrumentation Applications. International Journal of Applied Mathematics Electronics and Computers. Aralık 2016;(Special Issue-1):363-367. doi:10.18100/ijamec.280497
Chicago Çini, Uğur. “Current-Mode Rail-to Rail Instrumentation Amplifier for General Purpose Instrumentation Applications”. International Journal of Applied Mathematics Electronics and Computers, sy. Special Issue-1 (Aralık 2016): 363-67. https://doi.org/10.18100/ijamec.280497.
EndNote Çini U (01 Aralık 2016) Current-Mode Rail-to Rail Instrumentation Amplifier for General Purpose Instrumentation Applications. International Journal of Applied Mathematics Electronics and Computers Special Issue-1 363–367.
IEEE U. Çini, “Current-Mode Rail-to Rail Instrumentation Amplifier for General Purpose Instrumentation Applications”, International Journal of Applied Mathematics Electronics and Computers, sy. Special Issue-1, ss. 363–367, Aralık 2016, doi: 10.18100/ijamec.280497.
ISNAD Çini, Uğur. “Current-Mode Rail-to Rail Instrumentation Amplifier for General Purpose Instrumentation Applications”. International Journal of Applied Mathematics Electronics and Computers Special Issue-1 (Aralık 2016), 363-367. https://doi.org/10.18100/ijamec.280497.
JAMA Çini U. Current-Mode Rail-to Rail Instrumentation Amplifier for General Purpose Instrumentation Applications. International Journal of Applied Mathematics Electronics and Computers. 2016;:363–367.
MLA Çini, Uğur. “Current-Mode Rail-to Rail Instrumentation Amplifier for General Purpose Instrumentation Applications”. International Journal of Applied Mathematics Electronics and Computers, sy. Special Issue-1, 2016, ss. 363-7, doi:10.18100/ijamec.280497.
Vancouver Çini U. Current-Mode Rail-to Rail Instrumentation Amplifier for General Purpose Instrumentation Applications. International Journal of Applied Mathematics Electronics and Computers. 2016(Special Issue-1):363-7.