EVALUATING ON EXERGY ANALYSIS OF REFRIGERATION SYSTEM WITH TWO-STAGE AND ECONOMISER

Volume: 4 Number: 4 December 1, 2012
EN

EVALUATING ON EXERGY ANALYSIS OF REFRIGERATION SYSTEM WITH TWO-STAGE AND ECONOMISER

Abstract

In this study, the first and second law analysis of vapor compression refrigeration cycle with two-stage and economiser were carried out. R134a was used in system as refrigerant. The necessary thermodynamic values for analyses were calculated by Solkane program. The coefficient of performance (COP), exergetic efficiency (ηex) and total irreversibility rate of the system in the different operating conditions were investigated for this refrigerant. As a result, the highest coefficient of performance value and exergy efficiency value was obtained in the condenser temperature 25 oC and evaporator temperature 5 oC in the refrigeration system with two-stage and economiser. The highest irreversibility value was obtained in the condenser temperature 45 oC and evaporator temperature -15 oC in the refrigeration system

Keywords

References

  1. Zhang, J., Xu, Q., Cascade refrigeration system synthesis based on exergy analysis. Computers and Chemical Engineering, 35, 1901– 1914, 2011.
  2. Ahamed, J.U., Saidur, R., Masjuki H.H., A review on exergy analysis of vapor compression refrigeration system. Renewable and Sustainable Energy Reviews, 15, 1593–1600, 2011.
  3. Lucia, U., Second law analysis of the ideal Ericsson magnetic refrigeration. Renewable and Sustainable Energy Reviews, 15, 2872– 2875. 2011
  4. Rezayan, O., Ali Behbahaninia, A., Thermoeconomic optimization and exergy analysis of CO2/NH3 cascade refrigeration systems. Energy, 36, 888–895, 2011.
  5. Shuxue, X., Guoyuan. M., Exergy analysis for quasi two-stage compression heat pump system coupled with ejector. Experimental Thermal and Fluid Science, 35, 700–705, 2011.
  6. Aprea, C., Renno, C., Experimental comparison of R22 with R417A performance in a vapour compression refrigeration plant subjected to a cold store. Energy Convers Manage, 45,1807–1819, 2004.
  7. Cengel, A.Y. and Boles, A.M., Thermodynamics: An Engineering Approach, McGrawHill, New York, A.B.D., 1994.
  8. Arora, A., Kaushik, S.C., Theoretical analysis of a vapour compression refrigeration system with R502, R404A and R507A. Inter. J. Refriger., 31, 998-1005, 2008.

Details

Primary Language

English

Subjects

-

Journal Section

-

Authors

Bayram Kılıç This is me
Mehmet Akif Ersoy University, Bucak Emin Gülmez Vocational School, Bucak, Burdur, Turkey

Osman İpek This is me
Süleyman Demirel University, Engineering&Architecture Faculty, Mechanical Engineering, Isparta, Turkey

Sinan Uğuz
Mehmet Akif Ersoy University, Bucak Zeliha Tolunay Applied Technology and Management School, Bucak, Burdur, Turkey

Publication Date

December 1, 2012

Submission Date

December 1, 2012

Acceptance Date

-

Published in Issue

Year 2012 Volume: 4 Number: 4

APA
Kılıç, B., İpek, O., & Uğuz, S. (2012). EVALUATING ON EXERGY ANALYSIS OF REFRIGERATION SYSTEM WITH TWO-STAGE AND ECONOMISER. International Journal of Engineering and Applied Sciences, 4(4), 15-25. https://izlik.org/JA97MA96CU
AMA
1.Kılıç B, İpek O, Uğuz S. EVALUATING ON EXERGY ANALYSIS OF REFRIGERATION SYSTEM WITH TWO-STAGE AND ECONOMISER. IJEAS. 2012;4(4):15-25. https://izlik.org/JA97MA96CU
Chicago
Kılıç, Bayram, Osman İpek, and Sinan Uğuz. 2012. “EVALUATING ON EXERGY ANALYSIS OF REFRIGERATION SYSTEM WITH TWO-STAGE AND ECONOMISER”. International Journal of Engineering and Applied Sciences 4 (4): 15-25. https://izlik.org/JA97MA96CU.
EndNote
Kılıç B, İpek O, Uğuz S (December 1, 2012) EVALUATING ON EXERGY ANALYSIS OF REFRIGERATION SYSTEM WITH TWO-STAGE AND ECONOMISER. International Journal of Engineering and Applied Sciences 4 4 15–25.
IEEE
[1]B. Kılıç, O. İpek, and S. Uğuz, “EVALUATING ON EXERGY ANALYSIS OF REFRIGERATION SYSTEM WITH TWO-STAGE AND ECONOMISER”, IJEAS, vol. 4, no. 4, pp. 15–25, Dec. 2012, [Online]. Available: https://izlik.org/JA97MA96CU
ISNAD
Kılıç, Bayram - İpek, Osman - Uğuz, Sinan. “EVALUATING ON EXERGY ANALYSIS OF REFRIGERATION SYSTEM WITH TWO-STAGE AND ECONOMISER”. International Journal of Engineering and Applied Sciences 4/4 (December 1, 2012): 15-25. https://izlik.org/JA97MA96CU.
JAMA
1.Kılıç B, İpek O, Uğuz S. EVALUATING ON EXERGY ANALYSIS OF REFRIGERATION SYSTEM WITH TWO-STAGE AND ECONOMISER. IJEAS. 2012;4:15–25.
MLA
Kılıç, Bayram, et al. “EVALUATING ON EXERGY ANALYSIS OF REFRIGERATION SYSTEM WITH TWO-STAGE AND ECONOMISER”. International Journal of Engineering and Applied Sciences, vol. 4, no. 4, Dec. 2012, pp. 15-25, https://izlik.org/JA97MA96CU.
Vancouver
1.Bayram Kılıç, Osman İpek, Sinan Uğuz. EVALUATING ON EXERGY ANALYSIS OF REFRIGERATION SYSTEM WITH TWO-STAGE AND ECONOMISER. IJEAS [Internet]. 2012 Dec. 1;4(4):15-2. Available from: https://izlik.org/JA97MA96CU

21357