BibTex RIS Kaynak Göster

Comparison of Microwave and Conventional Driven Adsorption Heat Pump Cycle Duration

Yıl 2015, Cilt: 1 Sayı: 1, 8 - 12, 23.01.2015
https://doi.org/10.19072/ijet.105698

Öz

The present experimental study includes comparison of microwave regenerated and conventional heated adsorbent bed of adsorption heat pump. The novel adsorption heat pump driving with microwave heating system was designed and manufactured. Microwave oven was constructed for providing homogeneous temperature distribution in the adsorbent bed. Temperature and pressure variations in the adsorption heat pump for both microwave and conventional regenerated cycles were measured and investigated. Duration of isobaric desorption process with microwave heating was achieved 98.2% shorter than that of conventional heating system.

Kaynakça

  • H. Demir, M. Mobedi, S. Ulku, “A review on adsorption heat pump: Problems and solutions”, Renew. Sustain. Energy Rev, vol. 12, pp. 2381–2403, 2008.
  • K.E. Haque, “Microwave energy for mineral treatment processes: a brief review”, Int. J. Miner. Process. vol. 57, pp. 1-24, 1999.
  • M. Kumja, C.K. Ng, C. Yap, H. Yanaghi, S. Koyama, B.B. Saha, A.Chakraborty, “Modeling of a novel desorption cycle by dielectric heating”, Mod. Physic. Lett. B, vol. 23, pp. 425-428, 2009.
  • H. Demir, “The effect of microwave regenerated adsorbent bed on the performance of an adsorption heat pump”, Appl. Therm. Eng. Vol. 50, pp. 134-142, 2013.
  • G. Alefeld, P. Maier-Laxhuber, M. Rothmeyer, “Zeolite heat pump and zeolite heat transformer for load management”, In: Proc. of solid sorption refrigeration symposium, Paris, pp. 855-860, November 1992.
Yıl 2015, Cilt: 1 Sayı: 1, 8 - 12, 23.01.2015
https://doi.org/10.19072/ijet.105698

Öz

Kaynakça

  • H. Demir, M. Mobedi, S. Ulku, “A review on adsorption heat pump: Problems and solutions”, Renew. Sustain. Energy Rev, vol. 12, pp. 2381–2403, 2008.
  • K.E. Haque, “Microwave energy for mineral treatment processes: a brief review”, Int. J. Miner. Process. vol. 57, pp. 1-24, 1999.
  • M. Kumja, C.K. Ng, C. Yap, H. Yanaghi, S. Koyama, B.B. Saha, A.Chakraborty, “Modeling of a novel desorption cycle by dielectric heating”, Mod. Physic. Lett. B, vol. 23, pp. 425-428, 2009.
  • H. Demir, “The effect of microwave regenerated adsorbent bed on the performance of an adsorption heat pump”, Appl. Therm. Eng. Vol. 50, pp. 134-142, 2013.
  • G. Alefeld, P. Maier-Laxhuber, M. Rothmeyer, “Zeolite heat pump and zeolite heat transformer for load management”, In: Proc. of solid sorption refrigeration symposium, Paris, pp. 855-860, November 1992.
Toplam 5 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Bölüm Makaleler
Yazarlar

Hasan Demir

Yayımlanma Tarihi 23 Ocak 2015
Yayımlandığı Sayı Yıl 2015 Cilt: 1 Sayı: 1

Kaynak Göster

APA Demir, H. (2015). Comparison of Microwave and Conventional Driven Adsorption Heat Pump Cycle Duration. International Journal of Engineering Technologies IJET, 1(1), 8-12. https://doi.org/10.19072/ijet.105698
AMA Demir H. Comparison of Microwave and Conventional Driven Adsorption Heat Pump Cycle Duration. IJET. Mart 2015;1(1):8-12. doi:10.19072/ijet.105698
Chicago Demir, Hasan. “Comparison of Microwave and Conventional Driven Adsorption Heat Pump Cycle Duration”. International Journal of Engineering Technologies IJET 1, sy. 1 (Mart 2015): 8-12. https://doi.org/10.19072/ijet.105698.
EndNote Demir H (01 Mart 2015) Comparison of Microwave and Conventional Driven Adsorption Heat Pump Cycle Duration. International Journal of Engineering Technologies IJET 1 1 8–12.
IEEE H. Demir, “Comparison of Microwave and Conventional Driven Adsorption Heat Pump Cycle Duration”, IJET, c. 1, sy. 1, ss. 8–12, 2015, doi: 10.19072/ijet.105698.
ISNAD Demir, Hasan. “Comparison of Microwave and Conventional Driven Adsorption Heat Pump Cycle Duration”. International Journal of Engineering Technologies IJET 1/1 (Mart 2015), 8-12. https://doi.org/10.19072/ijet.105698.
JAMA Demir H. Comparison of Microwave and Conventional Driven Adsorption Heat Pump Cycle Duration. IJET. 2015;1:8–12.
MLA Demir, Hasan. “Comparison of Microwave and Conventional Driven Adsorption Heat Pump Cycle Duration”. International Journal of Engineering Technologies IJET, c. 1, sy. 1, 2015, ss. 8-12, doi:10.19072/ijet.105698.
Vancouver Demir H. Comparison of Microwave and Conventional Driven Adsorption Heat Pump Cycle Duration. IJET. 2015;1(1):8-12.

ijet@gelisim.edu.tr

 Alıntı-Gayriticari-Türetilemez 4.0 Uluslararası (CC BY-NC-ND 4.0)