Mitigation Harmonic with LCL Passive Fitler in off-Grid PV System
Abstract
Working of power systems stable and safety depends on the foundation of quantities such as voltage and current which are sinusoidal and 50 Hz frequency. However, these foundation quantities lose their sinusoidal characteristics because of many reasons unwanted harmonics component occur in the off-grid power system. It is a highly preferred method to use passive LCL filter for reduction harmonic components occur in the solar system.The proposed power system is a combination of solar panels, DC/DC boost converter , solar inverter, six-pulse rectifier, passive LCL filters and R-L inductive load. A six-pulse uncontrolled rectifier produces 5th, 7th, 11th, 13th, 17th, 19th, etc. harmonics components.A passive LCL filter is used to reduce input current of Total Harmonic Distortion (THDI) of three-phase uncontrolled rectifier. Off-grid power system is modeled by using Matlab/Simulink package program. Simulation results show that THDI value reduced from 89,89 % to 2,927 %. As a result, LCL filter improves both system efficiency and reliability in off-grid power system.
Keywords
References
- [1] Liu, Q., Peng, L., Kang, Y. S., Tang, D., Wu, L. and Qi, Y. (2014). A noveldesign and optimization method of an LCL filter for a shunt activepower filter,” IEEE Trans. Ind. Electron., vol. 61, no. 8, pp. 4000–4010,Aug.
- [2] Bao, C. Ruan, X. Wang, X. Li, W. Pan, D. and Weng, K. (2014). Step-by-stepcontroller design for LCL-type grid-connected inverter with capacitor–current-feedback active-damping, IEEE Trans. Power Electron., vol. 29,no. 3, pp. 1239–1253, Mar.
- [3] Xing, Z., Hong, Z., Fei, L., Fang, L., Chun, L. and Benxuan, L. (2013). An LCL-LC power filter for grid-tied inverter, in Proc. TENCON IEEE Region 10 Conf. (31194), 2013, pp. 1–4.
- [4] Cangi, H., Adak, S. (2015). Analysis of solar inverter THD according to PWM’s carrier frequency, IEEE Xplore Digital Library, DOI 10.1109/ICRERA. 2015,7418694, INSPEC Accession no:15807201.
- [5] Dannehl, J., Fuchs, F.W., Hansen, S. and Thogersen, P.B.(2010). Investigation ofActive Damping Approaches for PI-Based Current Control of Grid- Connected Pulse Width Modulation Converters with LCL Filters, IEEE. Trans. Industrial Applications, vol. 46, pp. 1509-1517.
- [6] TavakoliBina, M. and Pashajavid, E.(2009). An efficient procedure to design passive LCL-filters for active power filters, Electric Power Systems Research, vol. 79, no. 4, pp. 606–614, April.
- [7] Malla, S. G., Bhende, C.N. (2014). Voltage control of stand-alone wind and solar energy system, Elsevier: International Journal of Electrical Power & Energy Systems, Vol. 56, pp. 361-373, March.
- [8] San-Sebastian, J., Etxeberria-Otadui, I. A., Rujas, Barrena, J. A. and Rodriguez, P. (2012). Optimized LCL filter design methodology applied to MV grid-connected multimegawatt VSC, in Energy Conversion Congress and Exposition (ECCE), IEEE, 2012, pp. 2506-2512.