Research Article

The difference between the cycloplegic and noncycloplegic refractive error may be an indicator for the myopia progression in myopic children

Volume: 5 Number: 1 January 17, 2022
EN

The difference between the cycloplegic and noncycloplegic refractive error may be an indicator for the myopia progression in myopic children

Abstract

Aim: We aimed to evaluate the relationship between the subjective and objective refractive error measurement difference and myopia progression in this study. Material and Method: Children between 6-18 year-old at the beginning of the follow-up period having myopia and who were followed up regularly every six months and for a total of at least 36 months were included in the study. All children underwent a detailed ophthalmologic examination. An autorefractor (TOPCON KR1/RM1, Topcon, Oakland, New Jersey), was used to evaluate the refractive error. Those with a refractive error difference of less than 0.50 D (spherical equivalent) before and after cycloplegia were included in group 1. Those with a refractive error difference of higher than 0.50 D were included in group 2. Myopic progression of the groups was compared. Results: This study comprised 44 patients (male, 23; female, 21) in group 1 and 42 patients (male, 22; female, 20) in group 2. The age range and mean age±SD of patients in group 1 were 6-17 years and 11.4±3.0 years, respectively, whereas that of patients in group 2 was 6-17 years and 12.6±3.3 years, respectively. Both groups were followed for similar periods (p= 0.141). It was 37.5±2.4 (range 36-48) months in group 1 and 36.8±1.6 (range 36-42) months in group 2. The range and mean of the cycloplegic refractive error at the beginning of the following period in group 1 were -2.37±1.15 D, and -1.75±0.99 D in group 2 respectively (p= 0.010). At the end of the following period, the mean cycloplegic refractive error were -2.73±1.11 D in group 1, and -3,33±0.91 D in group 2 respectively (p= 0.008). During follow-up, the change in cycloplegic refractive error was 0.36±0.16 D in group 1, and 1.57±0.46 D in group 2. It was significantly lower in group 1 than group 2 (p< 0.0001). Conclusion: We demonstrated that myopic children having high baseline difference between the objective and subjective spheric equivalent measurements had more myopia progression.

Keywords

References

  1. Vitale S, Sperduto RD, Ferris FL, 3rd Increased prevalence of myopia in the United States between 1971-1972 and 1999-2004. Arch Ophthalmol 2009; 127: 1632-9.
  2. Saw SM, Gazzard G, Shih-Yen EC, Chua WH. Myopia and associated pathological complications. Ophthalmic Physiol Opt 2005; 25: 381-91.
  3. Hammond CJ, Snieder H, Gilbert CE, Spector TD. Genes and environment in refractive error: the twin eye study. Invest Ophthalmol Vis Sci 2001; 42: 1232-6.
  4. Fan DSP, Lam DSC, Lam RF, et al. Prevalence, incidence, and progression of myopia of school children in Hong Kong. Invest Ophthalmol Vis Sci 2004; 45: 1071-5.
  5. Zadnik K, Sinnott LT, Cotter SA, et al. Prediction of juvenile-onset myopia. JAMA Ophthalmol 2015; 133: 683-9.
  6. Polling JR, Verhoeven VJ, Tideman JW, Klaver CC. Duke-Elder’s views on prognosis, prophylaxis, and treatment of myopia: way ahead of his time. Strabismus 2016; 24: 40-3.
  7. Fotouhi A, Morgan IG, Iribarren R, Khabazkhoob M, Hashemi H. Validity of noncycloplegic refraction in the assessment of refractive errors: the Tehran Eye Study. Acta Ophthalmol 2012; 90: 380-6.
  8. Chinese Medical Association of Ophthalmology DoR. Definition and classic criterion for distinguishing between true myopia and pseudo-myopia. Chinese J Ophthalmol 1986; 22: 184-5.

Details

Primary Language

English

Subjects

Health Care Administration

Journal Section

Research Article

Publication Date

January 17, 2022

Submission Date

November 1, 2021

Acceptance Date

December 30, 2021

Published in Issue

Year 2022 Volume: 5 Number: 1

APA
Kocamış, S. İ., & Özdemir, İ. (2022). The difference between the cycloplegic and noncycloplegic refractive error may be an indicator for the myopia progression in myopic children. Journal of Health Sciences and Medicine, 5(1), 287-290. https://doi.org/10.32322/jhsm.1017563
AMA
1.Kocamış Sİ, Özdemir İ. The difference between the cycloplegic and noncycloplegic refractive error may be an indicator for the myopia progression in myopic children. J Health Sci Med / JHSM. 2022;5(1):287-290. doi:10.32322/jhsm.1017563
Chicago
Kocamış, Sücattin İlker, and İbrahim Özdemir. 2022. “The Difference Between the Cycloplegic and Noncycloplegic Refractive Error May Be an Indicator for the Myopia Progression in Myopic Children”. Journal of Health Sciences and Medicine 5 (1): 287-90. https://doi.org/10.32322/jhsm.1017563.
EndNote
Kocamış Sİ, Özdemir İ (January 1, 2022) The difference between the cycloplegic and noncycloplegic refractive error may be an indicator for the myopia progression in myopic children. Journal of Health Sciences and Medicine 5 1 287–290.
IEEE
[1]S. İ. Kocamış and İ. Özdemir, “The difference between the cycloplegic and noncycloplegic refractive error may be an indicator for the myopia progression in myopic children”, J Health Sci Med / JHSM, vol. 5, no. 1, pp. 287–290, Jan. 2022, doi: 10.32322/jhsm.1017563.
ISNAD
Kocamış, Sücattin İlker - Özdemir, İbrahim. “The Difference Between the Cycloplegic and Noncycloplegic Refractive Error May Be an Indicator for the Myopia Progression in Myopic Children”. Journal of Health Sciences and Medicine 5/1 (January 1, 2022): 287-290. https://doi.org/10.32322/jhsm.1017563.
JAMA
1.Kocamış Sİ, Özdemir İ. The difference between the cycloplegic and noncycloplegic refractive error may be an indicator for the myopia progression in myopic children. J Health Sci Med / JHSM. 2022;5:287–290.
MLA
Kocamış, Sücattin İlker, and İbrahim Özdemir. “The Difference Between the Cycloplegic and Noncycloplegic Refractive Error May Be an Indicator for the Myopia Progression in Myopic Children”. Journal of Health Sciences and Medicine, vol. 5, no. 1, Jan. 2022, pp. 287-90, doi:10.32322/jhsm.1017563.
Vancouver
1.Sücattin İlker Kocamış, İbrahim Özdemir. The difference between the cycloplegic and noncycloplegic refractive error may be an indicator for the myopia progression in myopic children. J Health Sci Med / JHSM. 2022 Jan. 1;5(1):287-90. doi:10.32322/jhsm.1017563

Interuniversity Board (UAK) Equivalency: Article published in Ulakbim TR Index journal [10 POINTS], and Article published in other (excuding 1a, b, c) international indexed journal (1d) [5 POINTS].

The Directories (indexes) and Platforms we are included in are at the bottom of the page.

Note: Our journal is not WOS indexed and therefore is not classified as Q.

You can download Council of Higher Education (CoHG) [Yüksek Öğretim Kurumu (YÖK)] Criteria) decisions about predatory/questionable journals and the author's clarification text and journal charge policy from your browser. https://dergipark.org.tr/tr/journal/2316/file/4905/show







The indexes of the journal are ULAKBİM TR Dizin, ICI World of Journals, DOAJ, Directory of Research Journals Indexing (DRJI), General Impact Factor, ASOS Index, WorldCat (OCLC), MIAR, OpenAIRE, Türkiye Citation Index, Türk Medline Index, InfoBase Index, Scilit, etc.

       images?q=tbn:ANd9GcRB9r6zRLDl0Pz7om2DQkiTQXqDtuq64Eb1Qg&usqp=CAU

500px-WorldCat_logo.svg.png

atifdizini.png

logo_world_of_journals_no_margin.png

images?q=tbn%3AANd9GcTNpvUjQ4Ffc6uQBqMQrqYMR53c7bRqD9rohCINkko0Y1a_hPSn&usqp=CAU

doaj.png  

images?q=tbn:ANd9GcSpOQFsFv3RdX0lIQJC3SwkFIA-CceHin_ujli_JrqBy3A32A_Tx_oMoIZn96EcrpLwTQg&usqp=CAU

ici2.png

asos-index.png

drji.png





The platforms of the journal are Google Scholar, CrossRef (DOI), ResearchBib, Open Access, COPE, ICMJE, NCBI, ORCID, Creative Commons, etc.

COPE-logo-300x199.jpgimages?q=tbn:ANd9GcQR6_qdgvxMP9owgnYzJ1M6CS_XzR_d7orTjA&usqp=CAU

icmje_1_orig.png

cc.logo.large.png

ncbi.pngimages?q=tbn:ANd9GcRBcJw8ia8S9TI4Fun5vj3HPzEcEKIvF_jtnw&usqp=CAU

ORCID_logo.png

1*mvsP194Golg0Dmo2rjJ-oQ.jpeg


Our Journal using the DergiPark system indexed are;

Ulakbim TR Dizin,  Index Copernicus, ICI World of JournalsDirectory of Research Journals Indexing (DRJI), General Impact FactorASOS Index, OpenAIRE, MIAR,  EuroPub, WorldCat (OCLC)DOAJ,  Türkiye Citation Index, Türk Medline Index, InfoBase Index


Our Journal using the DergiPark system platforms are;

Google, Google Scholar, CrossRef (DOI), ResearchBib, ICJME, COPE, NCBI, ORCID, Creative Commons, Open Access, and etc.


Journal articles are evaluated as "Double-Blind Peer Review". 

Our journal has adopted the Open Access Policy and articles in JHSM are Open Access and fully comply with Open Access instructions. All articles in the system can be accessed and read without a journal user.  https//dergipark.org.tr/tr/pub/jhsm/page/9535

Journal charge policy   https://dergipark.org.tr/tr/pub/jhsm/page/10912

Our journal has been indexed in DOAJ as of May 18, 2020.

Our journal has been indexed in TR-Dizin as of March 12, 2021.


17873

Articles published in Journal of Health Sciences and Medicine have open access and are licensed under the Creative Commons CC BY-NC-ND 4.0 International License.