Research Article

Evaluation of spleen stiffness in healthy population: a vibration-controlled transient elastography study

Volume: 5 Number: 2 March 15, 2022
EN

Evaluation of spleen stiffness in healthy population: a vibration-controlled transient elastography study

Abstract

Aim: Vibration-controlled transient elastography (VCTE) is an accurate technique that has an increasing use. In recent years, VCTE was started to use in predicting spleen stiffness (SS). Portal vein pressure and flow have an impact on SS and in previous studies it was used to predict portal hypertension, esophageal varices. In this study, our aim was to evaluate the SS measurements in healthy population and its correlation with age, sex, liver stiffness measurement (LSM), continued attenuation parameter (CAP) and body mass index (BMI). Material and Method: We enrolled healthy volunteers who were agreed to participate to the study and collected age, sex, smoking history, alcohol consumption, body mass index before the VCTE procedure. Liver and spleen elastography were performed to all patients by VCTE. Results: A total of 97 participants were enrolled to the study, 15 patients were excluded and 82 patients included for the final analysis. There was no significant difference in SS, liver stiffness measurement LSM, CAP and BMI between females and males. There was no correlation between age and SS. There was a weak correlation between SS and LSM, SS and CAP and no correlation was found between SS and BMI. Conclusions: SS had a weak correlation with LSM and CAP but not with BMI, age and sex. There is no extra-large probe use in SS measurement and it was a challenge in participants with increased submucosal fat thickness. Multiple and repeatable studies needed to set an accurate cut-off point and evaluate the factors that impact on SS in healthy individuals.

Keywords

References

  1. Aykut UE, Akyuz U, Yesil A, et al. A comparison of FibroMeter™ NAFLD Score, NAFLD fibrosis score, and transient elastography as noninvasive diagnostic tools for hepatic fibrosis in patients with biopsy-proven non-alcoholic fatty liver disease. Scand J Gastroenterol 2014; 49: 1343-8.
  2. Ziol M, Handra-Luca A, Kettaneh A, et al. Noninvasive assessment of liver fibrosis by measurement of stiffness in patients with chronic hepatitis C. Hepatology 2005; 41: 48-54.
  3. Sasso M, Beaugrand M, de Ledinghen V, et al. Controlled attenuation parameter (CAP): a novel VCTE™ guided ultrasonic attenuation measurement for the evaluation of hepatic steatosis: preliminary study and validation in a cohort of patients with chronic liver disease from various causes. Ultrasound Med Biol 2010; 36: 1825-35.
  4. Hu X, Huang X, Hou J, Ding L, Su C, Meng F. Diagnostic accuracy of spleen stiffness to evaluate portal hypertension and esophageal varices in chronic liver disease: a systematic review and meta-analysis. Eur Radiol 2021; 31: 2392-404.
  5. Reiberger T. The value of liver and spleen stiffness for evaluation of portal hypertension in compensated cirrhosis. Hepatol Commun 2021.
  6. Mazur R, Celmer M, Silicki J, Hołownia D, Pozowski P, Międzybrodzki K. Clinical applications of spleen ultrasound elastography-a review. J Ultrason 2018; 18: 37-41.
  7. Yilmaz Y, Ergelen R, Akin H, Imeryuz N. Noninvasive detection of hepatic steatosis in patients without ultrasonographic evidence of fatty liver using the controlled attenuation parameter evaluated with transient elastography. Eur J Gastroenterol Hepatol 2013; 25: 1330-4.
  8. Yilmaz Y, Yesil A, Gerin F, et al. Detection of hepatic steatosis using the controlled attenuation parameter: a comparative study with liver biopsy. Scand J Gastroenterol 2014; 49: 611-6.

Details

Primary Language

English

Subjects

Health Care Administration

Journal Section

Research Article

Publication Date

March 15, 2022

Submission Date

February 16, 2022

Acceptance Date

March 6, 2022

Published in Issue

Year 2022 Volume: 5 Number: 2

APA
Kani, H. T., Keklikkıran, Ç., Ergenç, İ., & Yılmaz, Y. (2022). Evaluation of spleen stiffness in healthy population: a vibration-controlled transient elastography study. Journal of Health Sciences and Medicine, 5(2), 689-692. https://doi.org/10.32322/jhsm.1074776
AMA
1.Kani HT, Keklikkıran Ç, Ergenç İ, Yılmaz Y. Evaluation of spleen stiffness in healthy population: a vibration-controlled transient elastography study. J Health Sci Med / JHSM. 2022;5(2):689-692. doi:10.32322/jhsm.1074776
Chicago
Kani, Haluk Tarık, Çağlayan Keklikkıran, İlkay Ergenç, and Yusuf Yılmaz. 2022. “Evaluation of Spleen Stiffness in Healthy Population: A Vibration-Controlled Transient Elastography Study”. Journal of Health Sciences and Medicine 5 (2): 689-92. https://doi.org/10.32322/jhsm.1074776.
EndNote
Kani HT, Keklikkıran Ç, Ergenç İ, Yılmaz Y (March 1, 2022) Evaluation of spleen stiffness in healthy population: a vibration-controlled transient elastography study. Journal of Health Sciences and Medicine 5 2 689–692.
IEEE
[1]H. T. Kani, Ç. Keklikkıran, İ. Ergenç, and Y. Yılmaz, “Evaluation of spleen stiffness in healthy population: a vibration-controlled transient elastography study”, J Health Sci Med / JHSM, vol. 5, no. 2, pp. 689–692, Mar. 2022, doi: 10.32322/jhsm.1074776.
ISNAD
Kani, Haluk Tarık - Keklikkıran, Çağlayan - Ergenç, İlkay - Yılmaz, Yusuf. “Evaluation of Spleen Stiffness in Healthy Population: A Vibration-Controlled Transient Elastography Study”. Journal of Health Sciences and Medicine 5/2 (March 1, 2022): 689-692. https://doi.org/10.32322/jhsm.1074776.
JAMA
1.Kani HT, Keklikkıran Ç, Ergenç İ, Yılmaz Y. Evaluation of spleen stiffness in healthy population: a vibration-controlled transient elastography study. J Health Sci Med / JHSM. 2022;5:689–692.
MLA
Kani, Haluk Tarık, et al. “Evaluation of Spleen Stiffness in Healthy Population: A Vibration-Controlled Transient Elastography Study”. Journal of Health Sciences and Medicine, vol. 5, no. 2, Mar. 2022, pp. 689-92, doi:10.32322/jhsm.1074776.
Vancouver
1.Haluk Tarık Kani, Çağlayan Keklikkıran, İlkay Ergenç, Yusuf Yılmaz. Evaluation of spleen stiffness in healthy population: a vibration-controlled transient elastography study. J Health Sci Med / JHSM. 2022 Mar. 1;5(2):689-92. doi:10.32322/jhsm.1074776

Cited By

Interuniversity Board (UAK) Equivalency: Article published in Ulakbim TR Index journal [10 POINTS], and Article published in other (excuding 1a, b, c) international indexed journal (1d) [5 POINTS].

The Directories (indexes) and Platforms we are included in are at the bottom of the page.

Note: Our journal is not WOS indexed and therefore is not classified as Q.

You can download Council of Higher Education (CoHG) [Yüksek Öğretim Kurumu (YÖK)] Criteria) decisions about predatory/questionable journals and the author's clarification text and journal charge policy from your browser. https://dergipark.org.tr/tr/journal/2316/file/4905/show







The indexes of the journal are ULAKBİM TR Dizin, ICI World of Journals, DOAJ, Directory of Research Journals Indexing (DRJI), General Impact Factor, ASOS Index, WorldCat (OCLC), MIAR, OpenAIRE, Türkiye Citation Index, Türk Medline Index, InfoBase Index, Scilit, etc.

       images?q=tbn:ANd9GcRB9r6zRLDl0Pz7om2DQkiTQXqDtuq64Eb1Qg&usqp=CAU

500px-WorldCat_logo.svg.png

atifdizini.png

logo_world_of_journals_no_margin.png

images?q=tbn%3AANd9GcTNpvUjQ4Ffc6uQBqMQrqYMR53c7bRqD9rohCINkko0Y1a_hPSn&usqp=CAU

doaj.png  

images?q=tbn:ANd9GcSpOQFsFv3RdX0lIQJC3SwkFIA-CceHin_ujli_JrqBy3A32A_Tx_oMoIZn96EcrpLwTQg&usqp=CAU

ici2.png

asos-index.png

drji.png





The platforms of the journal are Google Scholar, CrossRef (DOI), ResearchBib, Open Access, COPE, ICMJE, NCBI, ORCID, Creative Commons, etc.

COPE-logo-300x199.jpgimages?q=tbn:ANd9GcQR6_qdgvxMP9owgnYzJ1M6CS_XzR_d7orTjA&usqp=CAU

icmje_1_orig.png

cc.logo.large.png

ncbi.pngimages?q=tbn:ANd9GcRBcJw8ia8S9TI4Fun5vj3HPzEcEKIvF_jtnw&usqp=CAU

ORCID_logo.png

1*mvsP194Golg0Dmo2rjJ-oQ.jpeg


Our Journal using the DergiPark system indexed are;

Ulakbim TR Dizin,  Index Copernicus, ICI World of JournalsDirectory of Research Journals Indexing (DRJI), General Impact FactorASOS Index, OpenAIRE, MIAR,  EuroPub, WorldCat (OCLC)DOAJ,  Türkiye Citation Index, Türk Medline Index, InfoBase Index


Our Journal using the DergiPark system platforms are;

Google, Google Scholar, CrossRef (DOI), ResearchBib, ICJME, COPE, NCBI, ORCID, Creative Commons, Open Access, and etc.


Journal articles are evaluated as "Double-Blind Peer Review". 

Our journal has adopted the Open Access Policy and articles in JHSM are Open Access and fully comply with Open Access instructions. All articles in the system can be accessed and read without a journal user.  https//dergipark.org.tr/tr/pub/jhsm/page/9535

Journal charge policy   https://dergipark.org.tr/tr/pub/jhsm/page/10912

Our journal has been indexed in DOAJ as of May 18, 2020.

Our journal has been indexed in TR-Dizin as of March 12, 2021.


17873

Articles published in Journal of Health Sciences and Medicine have open access and are licensed under the Creative Commons CC BY-NC-ND 4.0 International License.