FABRICATION OF A SCREW-RETAINED HYBRID PROSTHESIS FOLLOWING TREATMENT OF PERI-IMPLANT DEFECTS: A CASE REPORT
Abstract
The etiology of marginal bone loss around osseointegrated implants is primarily based on the biomechanical and/or microbial factors. If stresses and strains around dental implants under functional loading conditions are expected to exceed the physiologic tolerance thresholds of the alveolar bone, the fixed hybrid prosthesis might be a more reliable treatment of choice instead of fixed metal ceramic restorations. The purpose of this article is to report the 1-year follow-up of the periodontal and prosthetic rehabilitation of a patient who has presented with symptoms of peri-implantitis due to incorrectly planned implant supported fixed metal ceramic bridge which was later replaced with screw-retained hybrid prosthesis following the treatment of peri-implant defects. Treatment helped to maintain patient’s self-confidence and comfort, as well as favorable masticatory function. Rehabilitation with screw retained hybrid prosthesis is an ideal treatment of choice for maxillomandibular skeletal discrepancies.
Keywords
References
- van Steenberghe D, Naert I, Jacobs R, Quirynen M. Influence of inflammatory reactions vs. Occlusal loading on peri-implant marginal bone level. Adv Dent Res 1999;13:130-135.
- Sahin S, Cehreli MC, Yalcin E. The influence of functional forces on the biomechanics of implant-supported prostheses--a review. J Dent 2002;30(7-8):271-282.
- Isidor F. Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys. Clin Oral Implants Res 1996;7(2):143-152.
- Isidor F. Histological evaluation of peri-implant bone at implants subjected to occlusal overload or plaque accumulation. Clin Oral Implants Res 1997;8(1):1-9.
- Isidor F. Clinical probing and radiographic assessment in relation to the histologic bone level at oral implants in monkeys. Clin Oral Implants Res 1997;8(4):255-264.
- Isidor F. Mobility assessment with the periotest system in relation to histologic findings of oral implants. Int J Oral Maxillofac Implants 1998;13(3):377-383.
- Benaissa Alia, El Bahri Ould Chikha, Hadj Miloud Meddaha, Ali Merdjib, Bel abbes Bachir Bouiadjra. Effects of overloading in mastication on the mechanical behaviour of dental implants. Materials and Design 2013;47(1):210-217.
- Isidor F. Influence of forces on peri-implant bone. Clin Oral Implants Res 2006;17 (Suppl 2):8-18.
Details
Primary Language
English
Subjects
-
Journal Section
-
Publication Date
October 3, 2016
Submission Date
December 24, 2015
Acceptance Date
-
Published in Issue
Year 2016 Volume: 50 Number: 3