Research Article
BibTex RIS Cite

Comparison of endotracheal tube selection using age-based formulas across body-mass index groups in pediatric patients undergoing nasal intubation for dental treatment under general anesthesia

Year 2026, Volume: 7 Issue: 2, 249 - 254, 27.03.2026
https://izlik.org/JA99HF35WU

Abstract

Aims: Accurate endotracheal tube (ETT) selection is essential for pediatric nasal intubation, especially when using age-based predictive formulas. The modified Motoyama formula, which adjusts for nasal intubation by selecting a slightly smaller internal diameter and adding length to depth, is commonly used. However, its accuracy across different body-mass index (BMI) groups remains uncertain.
Methods: This retrospective study included 677 pediatric patients aged 2–10 years who underwent nasal intubation for dental procedures under general anesthesia. Actual ETT internal diameters and insertion depths were compared with values predicted by the modified Motoyama formula. Patients were stratified by BMI percentile into four groups. Statistical comparisons and Bland–Altman analyses were performed to evaluate prediction accuracy and agreement.
Results: The median ETT diameter (4.5 mm) closely matched the modified Motoyama estimate (4.25 mm; p=0.054), while the modified Motoyama formula significantly overestimated ETT insertion depth (actual: 15.5 cm vs. predicted: 16.5 cm), with a median difference of –1.5 cm (IQR: –3.0 to 0.0; p<0.001). BMI showed a weak but significant correlation with prediction errors for both diameter (r=0.165) and depth (r=0.185). No significant variation was found based on chronic disease status.
Conclusion: The modified Motoyama formula accurately predicts ETT diameter but tends to overestimate insertion depth in pediatric nasal intubation. Although higher BMI was associated with greater prediction error, this relationship was weak, suggesting that while age-based formulas remain useful, BMI-related variability should be interpreted cautiously when applying these formulas to improve airway safety and accuracy.

Ethical Statement

This retrospective study was approved by the Clinical Research Ethics Committee of Istanbul Medipol University on 22/06/2023 (Ethics Committee No: E-10840098-772.02-3949; Decision No: 532). The research was carried out in compliance with institutional ethical standards and with the principles of the 1964 Declaration of Helsinki, including its subsequent amendments and equivalent guidelines.

Supporting Institution

NONE

Thanks

NONE

References

  • Stein ML, Park RS, Kovatsis PG. Emerging trends, techniques, and equipment for airway management in pediatric patients. Paediatr Anaesth. 2020;30(3):269-279. doi:10.1111/pan.13814
  • Park S, Shin SW, Kim HJ, et al. Choice of the correct size of endotracheal tube in pediatric patients. Anesth Pain Med (Seoul). 2022;17(4):352-360. doi:10.17085/apm.22215
  • Tareerath M, Mangmeesri P. Accuracy of age-based formula to predict the size and depth of cuffed oral preformed endotracheal tubes in children undergoing tonsillectomy. Ear Nose Throat J. 2023;102(3):193-197. doi:10.1177/0145561320980511
  • Zhou M, Xu WY, Xu S, et al. Prediction of endotracheal tube size in pediatric patients: development and validation of machine learning models. Front Pediatr. 2022;10:970646. doi:10.3389/fped.2022.970646
  • Gupta B, Ahluwalia P. Prediction of endotracheal tube size in the pediatric age group by ultrasound: a systematic review and meta-analysis. J Anaesthesiol Clin Pharmacol. 2022;38(3):371-383. doi:10.4103/joacp.JOACP_650_20
  • Fenley H, Voorman M, Dove JT, Greene JS. Predicting pediatric tracheal airway size from anthropomorphic measurements. Int J Pediatr Otorhinolaryngol. 2020;134:110020. doi:10.1016/j.ijporl.2020.110020
  • Kim J, Jeon S. Nasotracheal intubation in pediatrics: a narrative review. J Dent Anesth Pain Med. 2024;24(2):81-90. doi:10.17245/jdapm.2024.24. 2.81
  • Manimalethu R, Krishna S, Shafy SZ, Hakim M, Tobias JD. Choosing endotracheal tube size in children: which formula is best? Int J Pediatr Otorhinolaryngol. 2020;134:110016. doi:10.1016/j.ijporl.2020.110016
  • Tsukamoto M, Yamanaka H, Yokoyama T. Predicting the appropriate size of the uncuffed nasotracheal tube for pediatric patients: a retrospective study. Clin Oral Investig. 2019;23(1):493-495. doi:10.1007/s00784-018-2774-6
  • Tsukamoto M, Taura S, Yamanaka H, Hitosugi T, Yokoyama T. Prediction of appropriate formula for nasotracheal tube size in developmental disability children. Clin Oral Investig. 2021;25(4):2077-2080. doi:10.1007/s00784-020-03517-9
  • Chou CH, Tsai CL, Lin KL, et al. A new formula to predict the size and insertion depth of cuffed nasotracheal tube in children receiving dental surgery: a retrospective study. Sci Rep. 2023;13(1):12585. doi:10.1038/s41598-023-39793-0
  • Kemper M, Dullenkopf A, Schmidt AR, Gerber A, Weiss M. Nasotracheal intubation depth in paediatric patients. Br J Anaesth. 2014;113(5):840-846. doi:10.1093/bja/aeu229
  • Altun D, Orhan-Sungur M, Ali A, Özkan-Seyhan T, Sivrikoz N, Çamcı E. The role of ultrasound in appropriate endotracheal tube size selection in pediatric patients. Paediatr Anaesth. 2017;27(10):1015-1020. doi:10. 1111/pan.13220
  • Zhuang PE, Lu JH, Wang WK, Cheng MH. A new formula based on height for determining endotracheal intubation depth in pediatrics: a prospective study. J Clin Anesth. 2023;86:111079. doi:10.1016/j.jclinane. 2023.111079
  • Saravia A, Saravia RW, Mudd P, Jones JW. Examining the pediatric subglottic airway by ultrasound: a systematic review. Int J Pediatr Otorhinolaryngol. 2023;166:111482. doi:10.1016/j.ijporl.2023.111482
  • Saini N, Reddy A, Hebbar C, Chauhan R, Singh N. Improving the conduit for nasal intubation-the patient's little finger. Paediatr Anaesth. 2024;34(1):92-93. doi:10.1111/pan.14777
  • Liu Y, Ma W, Liu J. Applications of airway ultrasound for endotracheal intubation in pediatric patients: a systematic review. J Clin Med. 2023; 12(4):1477. doi:10.3390/jcm12041477
  • Singh S, Jindal P, Ramakrishnan P, Raghuvanshi S. Prediction of endotracheal tube size in children by predicting subglottic diameter using ultrasonographic measurement versus traditional formulas. Saudi J Anaesth. 2019;13(2):93-99. doi:10.4103/sja.SJA_390_18
  • Ebenebe CU, Schriever K, Apostolidou S, et al. Recommendations for endotracheal tube insertion depths in children. Emerg Med J. 2023;40(8): 583-587. doi:10.1136/emermed-2022-212494
There are 19 citations in total.

Details

Primary Language English
Subjects Anaesthesiology
Journal Section Research Article
Authors

Hande Güngör 0000-0002-8920-1516

Ayşe İnce 0000-0003-2082-2602

Sümeyye Yıldız 0000-0002-8155-1618

Tümay Uludağ Yanaral 0000-0003-3917-8183

Submission Date January 13, 2026
Acceptance Date February 25, 2026
Publication Date March 27, 2026
IZ https://izlik.org/JA99HF35WU
Published in Issue Year 2026 Volume: 7 Issue: 2

Cite

AMA 1.Güngör H, İnce A, Yıldız S, Uludağ Yanaral T. Comparison of endotracheal tube selection using age-based formulas across body-mass index groups in pediatric patients undergoing nasal intubation for dental treatment under general anesthesia. J Med Palliat Care / JOMPAC / jompac. 2026;7(2):249-254. https://izlik.org/JA99HF35WU

TR DİZİN ULAKBİM and International Indexes (1d)

Interuniversity Board (UAK) Equivalency: Article published in Ulakbim TR Index journal [10 POINTS], and Article published in other (excuding 1a, b, c) international indexed journal (1d) [5 POINTS]



google-scholar.png


crossref.jpg

f9ab67f.png

asos-index.png


COPE.jpg

icmje_1_orig.png

cc.logo.large.png

ncbi.png


pn6krf5.jpg


Our journal is in TR-Dizin, DRJI (Directory of Research Journals Indexing, General Impact Factor, Google Scholar, Researchgate, CrossRef (DOI), ROAD, ASOS Index, Turk Medline Index, Eurasian Scientific Journal Index (ESJI), and Turkiye Citation Index.

EBSCO, DOAJ, OAJI and ProQuest Index are in process of evaluation. 

Journal articles are evaluated as "Double-Blind Peer Review"