Araştırma Makalesi

Serebroplasental oranın izole oligohidroamniyoslu hastalarda kötü perinatal sonuçların öngörülmesindeki yeri

Cilt: 4 Sayı: 12 1 Aralık 2020
PDF İndir
EN TR

Evaluation of cerebroplacental ratio as a new tool to predict adverse perinatal outcomes in patients with isolated oligohydramnios

Abstract

Aim: There is conflicting information in the literature regarding perinatal outcomes and management of isolated oligohydramniotic (IO) pregnancies. Recent studies show that IO is associated with poor perinatal outcomes. However, there is still no definitive method for deciding the optimal delivery timing for these patients. In this study, we aimed to assess the relationship between Doppler parameters, especially cerebro-placental ratio, and perinatal outcomes in isolated oligohydramnios (IO) patients. Methods: This prospective case control study was conducted between October-November 2018. A total of 98 patients were recruited and divided into two groups, as pregnant women with normal amounts of amniotic volume and the isolated oligohydramnios group. Oligohydramnios diagnosis was made by amniotic fluid index measurement (AFI<5 cm). Pregnancies with hypertension, fetal growth restriction, thrombophilia, preeclampsia, diabetes mellitus, preterm births and chromosomal/structural abnormalities were excluded. Cerebro placental ratios of groups were compared in terms of composite adverse outcomes, low APGAR score in 1st and 5th minutes, C/S operation due to non-reassuring fetal heart rate patterns, admission to neonatal intensive care unit and still births. Results: In the isolated oligohydramnios group (n=45) cerebro-placental ratio (CPR) was lower compared to control group (P<0.001). IO was associated with lower (APGAR score<7) 1st (55.6% vs. 7.5%, P<0.001) and 5th (13.3% vs. 1.9% P=0.028) minute APGAR scores and higher rates of NICU admission (26.7% vs. 3.8% P=0.001). Number of fetal distress cases was higher in patients with low CPR in the IO group (9 vs. 6 P=0.023). Conclusion: Measurement of CPR among IO patients seems useful for detection of fetuses with higher risk for poor neonatal outcomes.

Keywords

Kaynakça

  1. 1. Hill LM, Breckle R, Wolfgram KR, O’Brien PC. Oligohydramnios: ultrasonically detected incidence and subsequent fetal outcome. Am J Obstet Gynecol. 1983;147:407–10.
  2. 2. Mercer LJ, Brown LG, Petres RE, Messer RH. A survey of pregnancies complicated by decreased amniotic fluid. Am J Obstet Gynecol. 1984;149:355–61.
  3. 3. Youssef AA, Abdulla SA, Sayed EH, Salem HT, Abdelalim AM, Devoe LD. Superiority of amniotic fluid index over amniotic fluid pocket measurement for predicting bad fetal outcome. South Med J. 1993;86:426–9.
  4. 4. Magann EF, Kinsella MJ, Chauhan SP, McNamara MF, Gehring BW, Morrison JC. Does an amniotic fluid index of ≤5 cm necessitate delivery in high-risk pregnancies? A case–control study. Am J Obstet Gynecol. 1999;180:1354–9.
  5. 5. Driggers RW, Holcroft CJ, Blakemore KJ, Graham EM. An amniotic fluid index < or =5 cm within 7 days of delivery in the third trimester is not associated with decreasing umbilical arterial pH and base excess. J Perinatol. 2004;24:72–6.
  6. 6. Rutherford SE, Phelan JP, Smith CV, Jacobs N. The four-quadrant assessment of amniotic fluid volume: an adjunct to antepartum fetal heart rate testing. Obstet Gynecol. 1987;70:353–6.
  7. 7. Magann EF, Chauhan SP, Martin JN Jr. Is amniotic fluid volume status predictive of fetal acidosis at delivery? Aust N Z J Obstet Gynaecol. 2003;43:129–33.
  8. 8. Casey BM, McIntire DD, Bloom SL, Lucas MJ, Santos R, Twickler DM et al. Pregnancy outcomes after antepartum diagnosis of oligohydramnios at or beyond 34 weeks’ gestation. Am J Obstet Gynecol. 2000;182:909–12.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Kadın Hastalıkları ve Doğum

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

1 Aralık 2020

Gönderilme Tarihi

21 Kasım 2020

Kabul Tarihi

14 Ocak 2021

Yayımlandığı Sayı

Yıl 1970 Cilt: 4 Sayı: 12

Kaynak Göster

APA
Destegül, E., Akkaya, H., Büke, B., & Gürer, G. (2020). Evaluation of cerebroplacental ratio as a new tool to predict adverse perinatal outcomes in patients with isolated oligohydramnios. Journal of Surgery and Medicine, 4(12), 1169-1172. https://doi.org/10.28982/josam.829499
AMA
1.Destegül E, Akkaya H, Büke B, Gürer G. Evaluation of cerebroplacental ratio as a new tool to predict adverse perinatal outcomes in patients with isolated oligohydramnios. J Surg Med. 2020;4(12):1169-1172. doi:10.28982/josam.829499
Chicago
Destegül, Emre, Hatice Akkaya, Barış Büke, ve Güliz Gürer. 2020. “Evaluation of cerebroplacental ratio as a new tool to predict adverse perinatal outcomes in patients with isolated oligohydramnios”. Journal of Surgery and Medicine 4 (12): 1169-72. https://doi.org/10.28982/josam.829499.
EndNote
Destegül E, Akkaya H, Büke B, Gürer G (01 Aralık 2020) Evaluation of cerebroplacental ratio as a new tool to predict adverse perinatal outcomes in patients with isolated oligohydramnios. Journal of Surgery and Medicine 4 12 1169–1172.
IEEE
[1]E. Destegül, H. Akkaya, B. Büke, ve G. Gürer, “Evaluation of cerebroplacental ratio as a new tool to predict adverse perinatal outcomes in patients with isolated oligohydramnios”, J Surg Med, c. 4, sy 12, ss. 1169–1172, Ara. 2020, doi: 10.28982/josam.829499.
ISNAD
Destegül, Emre - Akkaya, Hatice - Büke, Barış - Gürer, Güliz. “Evaluation of cerebroplacental ratio as a new tool to predict adverse perinatal outcomes in patients with isolated oligohydramnios”. Journal of Surgery and Medicine 4/12 (01 Aralık 2020): 1169-1172. https://doi.org/10.28982/josam.829499.
JAMA
1.Destegül E, Akkaya H, Büke B, Gürer G. Evaluation of cerebroplacental ratio as a new tool to predict adverse perinatal outcomes in patients with isolated oligohydramnios. J Surg Med. 2020;4:1169–1172.
MLA
Destegül, Emre, vd. “Evaluation of cerebroplacental ratio as a new tool to predict adverse perinatal outcomes in patients with isolated oligohydramnios”. Journal of Surgery and Medicine, c. 4, sy 12, Aralık 2020, ss. 1169-72, doi:10.28982/josam.829499.
Vancouver
1.Emre Destegül, Hatice Akkaya, Barış Büke, Güliz Gürer. Evaluation of cerebroplacental ratio as a new tool to predict adverse perinatal outcomes in patients with isolated oligohydramnios. J Surg Med. 01 Aralık 2020;4(12):1169-72. doi:10.28982/josam.829499