Research Article

PREPARATION OF POLY(PYROMELLITIC DIANHYDRIDE-CO-THIONIN) MODIFIED VOLTAMMETRIC SENSOR FOR THE DETERMINATION OF EPICATECHIN

Volume: 5 Number: 3 September 1, 2018
EN

PREPARATION OF POLY(PYROMELLITIC DIANHYDRIDE-CO-THIONIN) MODIFIED VOLTAMMETRIC SENSOR FOR THE DETERMINATION OF EPICATECHIN

Abstract

In this study, the electrochemical oxidation of epicatechin and its voltammetric sensing is shown at a sensitive platinum electrode modified with poly(pyromellitic dianhydride-co-thionin). The electrochemical response of the sensor was improved in the presence of both electro-inactive (sucrose, fructose, lactose) and electroactive (gallic acid, cafeic acid, ascorbic acid) interferants and displayed an excellent analytical performance for the determination of epicatechin. A linear response was obtained over a range of epicatechin concentrations from 0.05 mM to 0.30 mM and was shown to be useful for quantifying low levels of epicatechin in phosphate buffer solution, PBS, pH 7.00. Regression coefficient (R2) was found to be to be 0.9969. Limit of detection (LOD) was calculated as 1.8 × 10-5 M by using 3s/m. Where m is the slope of the calibration curve and s is the standard deviation of the calibration graph calculated using the Excel Steyx function.

Keywords

References

  1. 1. Cui X, Fang X, Zhao H, Li Z, Ren H. An Electrochemical Sensor for Dopamine Based on Polydopamine Modified Reduced Graphene Oxide Anchored with Tin Dioxide and Gold Nanoparticles. Anal. Methods. 2017;9:5322-5332.
  2. 2. Jinn G.Y, Li H, Xu W.B. Sensitive Determination of Buformin Using Poly-Aminobenzoic Acid Modified Glassy Carbon Electrode. Journal of Pharmaceutical Analysis. 2012;26:458–461.
  3. 3. Gholivand M.B, Karimian N. Development of Piroxicam Sensor Based on Molecular Imprinted Polymer-Modified Carbon Paste Electrode. Materials Science and Engineering C. 2011;31:1844–1851.
  4. 4. Wang J, Wang H, Han S. Ultrasensitive Determination of Epicatechin, Rutin and Quercetin by Capillary Electrophoresis. Chemiluminescence Acta Chromatographica. 2012;24:679–688.
  5. 5. Sinha M, Das D.K, Manna K, Datta S, Ray T, Sil A.K, Dey S. Epicatechin ameliorates ionising radiation induced oxidative stress in mouse liver. Free Radical Research. 2012;467:842-849.
  6. 6. Das D.K, Sinha M, Khan A, Das K, Manna K, Dey S. Radiation Protection by Major Tea Polyphenol, Epicatechin. International Journal of Human Genetics. 2013;131:59-64.
  7. 7. Natsume M, Osakabe N, Oyama M, Sasaki M, Baba S, Nakamura Y. Structures of (-) Epicatechin Glucuronide Identified From Plasma and Urine After Oral Ingestion of (-) Epicatechin: Differences Between Human and Rat. Free Radical Bio Med, 2003;34:840-849.
  8. 8. Abdulkhaleq L.A, Assi M.A, Noor M.H.M, Abdullah R, Saad M.Z, Taufiq-Yap Y.H. Therapeutic Uses of Epicatechin in Diabetes and Cancer. Veterinary World. 2017;106:2231-0916.

Details

Primary Language

English

Subjects

Chemical Engineering

Journal Section

Research Article

Authors

Publication Date

September 1, 2018

Submission Date

July 23, 2018

Acceptance Date

September 8, 2018

Published in Issue

Year 2018 Volume: 5 Number: 3

APA
Titretir Duran, S. (2018). PREPARATION OF POLY(PYROMELLITIC DIANHYDRIDE-CO-THIONIN) MODIFIED VOLTAMMETRIC SENSOR FOR THE DETERMINATION OF EPICATECHIN. Journal of the Turkish Chemical Society Section A: Chemistry, 5(3), 1021-1028. https://doi.org/10.18596/jotcsa.446953
AMA
1.Titretir Duran S. PREPARATION OF POLY(PYROMELLITIC DIANHYDRIDE-CO-THIONIN) MODIFIED VOLTAMMETRIC SENSOR FOR THE DETERMINATION OF EPICATECHIN. JOTCSA. 2018;5(3):1021-1028. doi:10.18596/jotcsa.446953
Chicago
Titretir Duran, Serap. 2018. “PREPARATION OF POLY(PYROMELLITIC DIANHYDRIDE-CO-THIONIN) MODIFIED VOLTAMMETRIC SENSOR FOR THE DETERMINATION OF EPICATECHIN”. Journal of the Turkish Chemical Society Section A: Chemistry 5 (3): 1021-28. https://doi.org/10.18596/jotcsa.446953.
EndNote
Titretir Duran S (September 1, 2018) PREPARATION OF POLY(PYROMELLITIC DIANHYDRIDE-CO-THIONIN) MODIFIED VOLTAMMETRIC SENSOR FOR THE DETERMINATION OF EPICATECHIN. Journal of the Turkish Chemical Society Section A: Chemistry 5 3 1021–1028.
IEEE
[1]S. Titretir Duran, “PREPARATION OF POLY(PYROMELLITIC DIANHYDRIDE-CO-THIONIN) MODIFIED VOLTAMMETRIC SENSOR FOR THE DETERMINATION OF EPICATECHIN”, JOTCSA, vol. 5, no. 3, pp. 1021–1028, Sept. 2018, doi: 10.18596/jotcsa.446953.
ISNAD
Titretir Duran, Serap. “PREPARATION OF POLY(PYROMELLITIC DIANHYDRIDE-CO-THIONIN) MODIFIED VOLTAMMETRIC SENSOR FOR THE DETERMINATION OF EPICATECHIN”. Journal of the Turkish Chemical Society Section A: Chemistry 5/3 (September 1, 2018): 1021-1028. https://doi.org/10.18596/jotcsa.446953.
JAMA
1.Titretir Duran S. PREPARATION OF POLY(PYROMELLITIC DIANHYDRIDE-CO-THIONIN) MODIFIED VOLTAMMETRIC SENSOR FOR THE DETERMINATION OF EPICATECHIN. JOTCSA. 2018;5:1021–1028.
MLA
Titretir Duran, Serap. “PREPARATION OF POLY(PYROMELLITIC DIANHYDRIDE-CO-THIONIN) MODIFIED VOLTAMMETRIC SENSOR FOR THE DETERMINATION OF EPICATECHIN”. Journal of the Turkish Chemical Society Section A: Chemistry, vol. 5, no. 3, Sept. 2018, pp. 1021-8, doi:10.18596/jotcsa.446953.
Vancouver
1.Serap Titretir Duran. PREPARATION OF POLY(PYROMELLITIC DIANHYDRIDE-CO-THIONIN) MODIFIED VOLTAMMETRIC SENSOR FOR THE DETERMINATION OF EPICATECHIN. JOTCSA. 2018 Sep. 1;5(3):1021-8. doi:10.18596/jotcsa.446953

Cited By