PREPARATION OF POLY(PYROMELLITIC DIANHYDRIDE-CO-THIONIN) MODIFIED VOLTAMMETRIC SENSOR FOR THE DETERMINATION OF EPICATECHIN
Abstract
In this study, the electrochemical oxidation of epicatechin and its voltammetric sensing is shown at a sensitive platinum electrode modified with poly(pyromellitic dianhydride-co-thionin). The electrochemical response of the sensor was improved in the presence of both electro-inactive (sucrose, fructose, lactose) and electroactive (gallic acid, cafeic acid, ascorbic acid) interferants and displayed an excellent analytical performance for the determination of epicatechin. A linear response was obtained over a range of epicatechin concentrations from 0.05 mM to 0.30 mM and was shown to be useful for quantifying low levels of epicatechin in phosphate buffer solution, PBS, pH 7.00. Regression coefficient (R2) was found to be to be 0.9969. Limit of detection (LOD) was calculated as 1.8 × 10-5 M by using 3s/m. Where m is the slope of the calibration curve and s is the standard deviation of the calibration graph calculated using the Excel Steyx function.
Keywords
References
- 1. Cui X, Fang X, Zhao H, Li Z, Ren H. An Electrochemical Sensor for Dopamine Based on Polydopamine Modified Reduced Graphene Oxide Anchored with Tin Dioxide and Gold Nanoparticles. Anal. Methods. 2017;9:5322-5332.
- 2. Jinn G.Y, Li H, Xu W.B. Sensitive Determination of Buformin Using Poly-Aminobenzoic Acid Modified Glassy Carbon Electrode. Journal of Pharmaceutical Analysis. 2012;26:458–461.
- 3. Gholivand M.B, Karimian N. Development of Piroxicam Sensor Based on Molecular Imprinted Polymer-Modified Carbon Paste Electrode. Materials Science and Engineering C. 2011;31:1844–1851.
- 4. Wang J, Wang H, Han S. Ultrasensitive Determination of Epicatechin, Rutin and Quercetin by Capillary Electrophoresis. Chemiluminescence Acta Chromatographica. 2012;24:679–688.
- 5. Sinha M, Das D.K, Manna K, Datta S, Ray T, Sil A.K, Dey S. Epicatechin ameliorates ionising radiation induced oxidative stress in mouse liver. Free Radical Research. 2012;467:842-849.
- 6. Das D.K, Sinha M, Khan A, Das K, Manna K, Dey S. Radiation Protection by Major Tea Polyphenol, Epicatechin. International Journal of Human Genetics. 2013;131:59-64.
- 7. Natsume M, Osakabe N, Oyama M, Sasaki M, Baba S, Nakamura Y. Structures of (-) Epicatechin Glucuronide Identified From Plasma and Urine After Oral Ingestion of (-) Epicatechin: Differences Between Human and Rat. Free Radical Bio Med, 2003;34:840-849.
- 8. Abdulkhaleq L.A, Assi M.A, Noor M.H.M, Abdullah R, Saad M.Z, Taufiq-Yap Y.H. Therapeutic Uses of Epicatechin in Diabetes and Cancer. Veterinary World. 2017;106:2231-0916.
Details
Primary Language
English
Subjects
Chemical Engineering
Journal Section
Research Article
Authors
Serap Titretir Duran
*
Türkiye
Publication Date
September 1, 2018
Submission Date
July 23, 2018
Acceptance Date
September 8, 2018
Published in Issue
Year 2018 Volume: 5 Number: 3
Cited By
Voltammetric determination of florfenicol by using poly(3-methylthiophene) modified glassy carbon electrode
Polymer Bulletin
https://doi.org/10.1007/s00289-021-03732-8Electrochemical Detection of Epicatechin in Green Tea Using Quercetin-Imprinted Polymer Graphite Electrode
IEEE Sensors Journal
https://doi.org/10.1109/JSEN.2021.3122145Amine Functionalized MWCNTs Modified MIP-Based Electrode for Detection of Epicatechin in Tea
IEEE Sensors Journal
https://doi.org/10.1109/JSEN.2022.3169169Novel Electrochemical Sensing of Catechins in Raw Green Tea Extract via a Trimetallic Zeolitic Imidazolate Fibrous Framework
ACS Omega
https://doi.org/10.1021/acsomega.2c01536Integration of multiwalled carbon nanotubes with cobalt oxide for smart electrochemical sensing of epicatechin in foods
Carbon Trends
https://doi.org/10.1016/j.cartre.2022.100240Utilizing epicatechin voltammetric oxidation signal for the estimation of total phenolic content in the tea samples via the unmodified boron-doped diamond electrode surface
Microchemical Journal
https://doi.org/10.1016/j.microc.2023.108572Isatin-Schiff base functionalized graphene oxide as a highly selective turn-on fluorescent probe for the detection of Pd(II) via photoinduced electron transfer pathway
Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
https://doi.org/10.1016/j.saa.2023.123673Microwave-assisted synthesis of nickel-oxide/cobalt-oxide/reduced graphene oxide nanocomposite for highly sensitive electrochemical determination of epicatechin in food samples
Results in Chemistry
https://doi.org/10.1016/j.rechem.2024.101333
