Introduction:
There
is limited knowledge about the use of bioresorbable scaffolds (BRSs) in long
segment coronary artery lesions. We aimed to evaluate the clinical outcomes of
BRS-BRS and drug eluting stents (DESs)-BRS overlapping applications.
Patients
and Methods: Cross-sectional, single-center study between 2013 and
2016 enrolled 97 patients and 100 lesions scheduled for BRS placement in long
segment lesions (> 28 mm). BRS-BRS overlap was performed in 30 patients and
30 lesions, DES-BRS overlap was performed in 67 patients and 70 lesions. Acute
procedural success and major adverse cardiac events (MACE) (death, stent thrombosis,
and target lesion reintervention) were assessed.
Results: Acute
procedural success was 97.1% in the overall group. MACE was observed in 6
patients (6.2%) in the entire group, 4 (5.9%) in the DES-BRS group, and 2
(6.6%) in the BRS-BRS group.
Keywords
References
- 1. Ormiston JA, Serruys PWS. Bioabsorbable coronary stents. Circ Cardiovasc Interv 2009;2:255-60.
- 2. Serruys PW, Garcia-Garcia HM, Onuma Y. From metallic cages to transient bioresorbable caffolds: change in paradigm of coronary revascularization in the upcoming decade? Eur Heart J 2012;33:16-25.
- 3. Onuma Y, Dudek D, Thuesen L, Webster M, Nieman K, Garcia-Garcia HM, et al. Five-year clinical and functional multislice computed tomography angiographic results after coronary implantation of the fully resorbable polymeric everolimus-eluting scaffold in patients with de novo coronary artery disease: the ABSORB cohort A trial. JACC Cardiovasc Interv 2013;6:999-1009.
- 4. Räber L, Jüni P, Löffel L, Wandel S, Cook S, Wenaweser P, et al. Impact of stent overlap on angiographic and long-term clinical outcome in patients undergoing drug-eluting stent implantation. J Am Coll Cardiol 2010;55:1178-88.
- 5. Finn AV, Kolodgie FD, Harnek J, Guerrero LJ, Acampado E, Tefera K, et al. Differential response of delayed healing and persistent inflammation at sites of overlapping sirolimus- or paclitaxel-eluting stents. Circulation 2005;112:270-8.
- 6. Kitabata H, Loh JP, Pendyala LK, Badr S, Dvir D, Barbash IM, et al. Safety and efficacy outcomes of overlapping second-generation everolimus-eluting stents versus first-generation drug-eluting stents. Am J Cardiol 2013;112:1093-8.
- 7. Biscaglia S, Ugo F, Ielasi A, Secco GG, Durante A, D’Ascenzo F, et al. Bioresorbable scaffold vs. second generation drug eluting stent in long coronary lesions requiring overlap: a propensity-matched comparison (the UNDERDOGS study). Int J Cardiol 2016;208:40-5.
- 8. Ho HH, Jafary FH, Loh KK, Tan JK, Ooi YW, Ong PJ. Deliverability of integrity coronary stents in severely tortuous coronary arteries: a preliminary experience. J Invasive Cardiol 2012;24:650-4.
Details
Primary Language
English
Subjects
Clinical Sciences
Journal Section
Research Article
Authors
Tayyar Gökdeniz
This is me
İbrahim Oğuz Karaca
This is me
Gültekin Günhan Demir
This is me
Filiz Kızılırmak
This is me
Ekrem Güler
This is me
Gamze Babür Güler
This is me
Mehmet Onur Omaygenç
This is me
Umeyir Savur
This is me
Ersin İbişoğlu
This is me
Bilal Boztosun
This is me
Publication Date
April 1, 2018
Submission Date
December 2, 2018
Acceptance Date
-
Published in Issue
Year 2018 Volume: 21 Number: 1