Serial Fluoroscopy Guided Fibrinolytic Therapy in a Patient with Obstructive Mechanical Aortic Valve Thrombosis
Abstract
Prosthetic
valve thrombosis is a life-threatening complication, which is most commonly
seen in patients with poor anticoagulation. Although two-dimensional and
real-time three-dimensional transesophageal echocardiography are the gold
standard imaging modalities for the diagnosis of prosthetic valve thrombosis,
prosthetic valves in aortic position may not be evaluated precisely. This is a
serious problem during the follow-up of the patients who receive thrombolytic
therapy for aortic valve thrombosis. Fluoroscopy is an alternative noninvasive
imaging method, which provides valuable information about leaflet motion and
may be used for such cases with restricted leaflets. Here, we report a case of
aortic valve thrombosis that was managed with low-dose (25 mg) and ultra-slow
(25 hours) infusion of tissue-type plasminogen activator under the guidance of
serial fluoroscopy.
Keywords
References
- 1. Özkan M, Çakal B, Karakoyun S, Gürsoy OM, Çevik C, Kalçık M, et al. Thrombolytic therapy for the treatment of prosthetic heart valve thrombosis in pregnancy with low-dose, slow infusion of tissue-type plasminogen activator. Circulation 2013;128:532-40.
- 2. Özkan M, Gündüz S, Biteker M, Astarcioglu MA, Çevik C, Kaynak E, et al. Comparison of different TEE-guided thrombolytic regimens for prosthetic valve thrombosis: the TROIA trial. JACC Cardiovasc Imaging 2013;6:206-16.
- 3. Montorsi P, De Bernardi F, Muratori M, Cavoretto D, Pepi M. Role of cine-fluoroscopy, transthoracic, and transesophageal echocardiography in patients with suspected prosthetic heart valve thrombosis. Am J Cardiol 2000;85:58-64.
- 4. Licata A, Matthai WH Jr. Evaluating the etiology of mechanical valve obstruction: use of clinical parameters, fluoroscopy, and echocardiography. Catheter Cardiovasc Interv 2002;55:495-500.
- 5. Muratori M, Montorsi P, Maffessanti F, Teruzzi G, Zoghbi WA, Gripari P, et al. Dysfunction of bileaflet aortic prosthesis: accuracy of echocardiography versus fluoroscopy. JACC Cardiovasc Imaging 2013;6:196-205.
- 6. Montorsi P, Cavoretto D, Alimento M, Muratori M, Pepi M. Prosthetic mitral valve thrombosis: can fluoroscopy predict the efficacy of thrombolytic treatment? Circulation 2003;108(Suppl 1):II79-84.
- 7. Montorsi P, Cavoretto D, Ballerini G. Thrombosis of mechanical heart valve prostheses: revisiting the role of fluoroscopy. Br J Radiol 2000;73:76-9.
- 8. Cianciulli TF, Lax JA, Saccheri MC, Guidoin R, Salvado CM, Fernández AJ, et al. Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve. Eur J Echocardiogr 2008;9:65-8.
Details
Primary Language
English
Subjects
Clinical Sciences
Journal Section
Case Report
Authors
Mahmut Yesin
This is me
Mustafa Ozan Gürsoy
This is me
Mustafa Yıldız
This is me
Mehmet Özkan
This is me
Publication Date
December 1, 2016
Submission Date
December 1, 2016
Acceptance Date
-
Published in Issue
Year 2016 Volume: 19 Number: 3