<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.4 20241031//EN"
        "https://jats.nlm.nih.gov/publishing/1.4/JATS-journalpublishing1-4.dtd">
<article         dtd-version="1.4">
            <front>

                <journal-meta>
                                                                <journal-id>ktd</journal-id>
            <journal-title-group>
                                                                                    <journal-title>Kocatepe Tıp Dergisi</journal-title>
            </journal-title-group>
                                        <issn pub-type="epub">3061-9904</issn>
                                                                                            <publisher>
                    <publisher-name>Afyonkarahisar Sağlık Bilimleri Üniversitesi</publisher-name>
                </publisher>
                    </journal-meta>
                <article-meta>
                                        <article-id/>
                                                                                                                                                                                            <title-group>
                                                                                                                        <trans-title-group xml:lang="en">
                                    <trans-title>Ekspiratuar Valf Sisteminden Kaynaklanan Bir Hiperkarbi Olgusu</trans-title>
                                </trans-title-group>
                                                                                                                                                                                                <article-title>Ekspiratuar Valf Sisteminden Kaynaklanan Bir Hiperkarbi Olgusu</article-title>
                                                                                                    </title-group>
            
                                                    <contrib-group content-type="authors">
                                                                        <contrib contrib-type="author">
                                                                <name>
                                    <surname>Eroğlu</surname>
                                    <given-names>Fisun</given-names>
                                </name>
                                                            </contrib>
                                                                                </contrib-group>
                        
                                        <pub-date pub-type="pub" iso-8601-date="20080801">
                    <day>08</day>
                    <month>01</month>
                    <year>2008</year>
                </pub-date>
                                        <volume>9</volume>
                                        <issue>2</issue>
                                        <fpage>41</fpage>
                                        <lpage>43</lpage>
                        
                        <history>
                                    <date date-type="received" iso-8601-date="20150508">
                        <day>05</day>
                        <month>08</month>
                        <year>2015</year>
                    </date>
                                            </history>
                                        <permissions>
                    <copyright-statement>Copyright © 1999, Kocatepe Tıp Dergisi</copyright-statement>
                    <copyright-year>1999</copyright-year>
                    <copyright-holder>Kocatepe Tıp Dergisi</copyright-holder>
                </permissions>
            
                                                                                                                        <abstract><p>Genel anestezi altında hiperkarbiyi saptamak güçtür. Anestezi altında hiperkarbinin en sık nedeni; karbondioksit absorbanının zamanında değiştirilmemesi ve valf sistemindeki arıza sonucu ekspire edilen gaz karışımındaki karbondioksitin etkili biçimde uzaklaştırılamadan tekrar solunmasıdır. Hiperkarbinin neden olduğu semptomların diğer stres cevaplarına benzerliğinden dolayı sıklıkla yanlış tanı konur. Bu yazıda, adenoidektomi operasyonu geçiren 3 yaşındaki erkek olgunun ameliyat sonunda uyanmada gecikme meydana geldi. Kas gevşetici olarak mivakuryum kullanılan olguda uyanmada gecikme psödokolinesteraz yetersizliğine olarak düşünüldü. Ancak yapılan değerlendirmede hiperkarbi nedeninin anestezi cihazının ekspiratuar valften kaynaklandığı saptandı. Operasyon sırasında hastaların durumlarındaki beklenmeyen değişikliklerin araştırılmasında olguların sistemik problemlerinin yanı sıra ekipman arızaları da göz önünde bulundurulmalıdır</p></abstract>
                                                            
            
                                                                                        <kwd-group>
                                                    <kwd>Hiperkarbi</kwd>
                                                    <kwd>   uyanmada gecikme</kwd>
                                                    <kwd>   anestezi devresi</kwd>
                                                    <kwd>   ekspiratuar valf</kwd>
                                            </kwd-group>
                            
                                                <kwd-group xml:lang="en">
                                                    <kwd>-</kwd>
                                            </kwd-group>
                                                                                                                                        </article-meta>
    </front>
    <back>
                            <ref-list>
                                    <ref id="ref1">
                        <label>1</label>
                        <mixed-citation publication-type="journal">Petitdidier M, Margarot M, Batier C, Millet A, Blanchet P, Roquefeuil B. Blood gas levels using spontaneous breathing and the Bain circuit. Our experience during head surgery. Anesth Analg. 1981; 38(9-10): 505-11.</mixed-citation>
                    </ref>
                                    <ref id="ref2">
                        <label>2</label>
                        <mixed-citation publication-type="journal">Jouan ZT, Jawan B, Lee JH. Hypercarbia induced by detachment of inner fresh gas delivery tube of the bain circuit--a case report. Acta Anaesthesiol Sin. 1995; 33(2): 129-32.</mixed-citation>
                    </ref>
                                    <ref id="ref3">
                        <label>3</label>
                        <mixed-citation publication-type="journal">Classen V, Uhrbrand B. Partial occlusion of the Bain circuit causes respiratory acidosis under general anesthesia. Ugeskr Laeger. 2002; 164(43): 5037-8.</mixed-citation>
                    </ref>
                                    <ref id="ref4">
                        <label>4</label>
                        <mixed-citation publication-type="journal">Cantwell SL, Modell JH. Inadvertent severe hypercarbia associated with anesthesia machine malfunction in one cat and two dogs. J Am Vet Med Assoc. 2001; 219(11): 1573-6.</mixed-citation>
                    </ref>
                                    <ref id="ref5">
                        <label>5</label>
                        <mixed-citation publication-type="journal">Cummings K 3rd. Carbon dioxide rebreathing due to unrecognized Amsorb Plus exhaustion. Anesth Analg. 2007; 105(1): 289.</mixed-citation>
                    </ref>
                                    <ref id="ref6">
                        <label>6</label>
                        <mixed-citation publication-type="journal">Lin SL, Yeh CC, Lu CH, Ho ST, Wong CS. Hypercapnia due to rupture of the unidirectional valve in the inspiratory limb of the breathing system after induction of general anesthesia--a case report. Acta Anaesthesiol Sin. 2003; 41(3): 139-43.</mixed-citation>
                    </ref>
                                    <ref id="ref7">
                        <label>7</label>
                        <mixed-citation publication-type="journal">Savarese JJ, Ali HH, Basta SJ, Embree PB, Scott RP, Sunder N, Weakly JN, Wastila WB, el-Sayad HA. The clinical neuromuscular pharmacology of mivacurium chloride (BW B1090U). A short-acting nondepolarizing ester neuromuscular blocking drug. Anesthesiology 1988; 68(5): 723-32.</mixed-citation>
                    </ref>
                                    <ref id="ref8">
                        <label>8</label>
                        <mixed-citation publication-type="journal">Cook DR, Freeman JA, Lai AA. Kang Y, Stiller RL, Aggarwal S, Harrelson JC, Welch RM, Samara B. Pharmacokinetics of mivacurium in normal patients and those with hepatic or renal failure. Br J Anaesth 1992; 69(6): 580-5.</mixed-citation>
                    </ref>
                                    <ref id="ref9">
                        <label>9</label>
                        <mixed-citation publication-type="journal">Mangat PS, Evans DE, Harmer M, Lunn JN. A comparison between mivacurium and suxamethonium in children. Anaesthesia 1993; 48(10): 866-9.</mixed-citation>
                    </ref>
                                    <ref id="ref10">
                        <label>10</label>
                        <mixed-citation publication-type="journal">Jensen FS, Viby-Mogensen J. Plasma cholinesterase and abnormal reaction to succinylcholine: twenty years&#039; experience with the Danish Cholinesterase Research Unit. Acta Anaesthesiol Scand 1995; 39(2): 150-6.</mixed-citation>
                    </ref>
                                    <ref id="ref11">
                        <label>11</label>
                        <mixed-citation publication-type="journal">Caplan RA, Vistica MF, Posner KL, Cheney FW. Adverse anesthetic outcomes arising from gas delivery equipment: a closed claims analysis. Anesthesiology 1997; 87(4): 741-8.</mixed-citation>
                    </ref>
                                    <ref id="ref12">
                        <label>12</label>
                        <mixed-citation publication-type="journal">Walton JS, Fears R, Burt N, Dorman BH. Intraoperative breathing circuit obstruction caused by albuterol nebulization. Anesth Analg. 1999; 89(3): 650-1.</mixed-citation>
                    </ref>
                                    <ref id="ref13">
                        <label>13</label>
                        <mixed-citation publication-type="journal">13-Hindman BJ, Sperring SJ. Partial expiratory limb obstruction by a foreign body abutting upon an Ohio 5400 Volume Monitor Sensor. Anesthesiology 1986; 65(3): 349-50.</mixed-citation>
                    </ref>
                                    <ref id="ref14">
                        <label>14</label>
                        <mixed-citation publication-type="journal">Krensavage TJ, Richards E. Sudden development of anesthesia circuit obstruction by an end-tidal CO2 cap in the gas sampling elbow. Anesth Analg. 1995; 81(1):207.</mixed-citation>
                    </ref>
                                    <ref id="ref15">
                        <label>15</label>
                        <mixed-citation publication-type="journal">McEwan AI, Dowell L, Karis JH. Bilateral tension pneumothorax caused by a blocked bacterial filter in an anesthesia breathing circuit. Anesth Analg. 1993; 76(2): 440-2.</mixed-citation>
                    </ref>
                                    <ref id="ref16">
                        <label>16</label>
                        <mixed-citation publication-type="journal">Smith CE, Otworth JR, Kaluszyk P. Bilateral tension pneumothorax due to a defective anesthesia breathing circuit filter. J Clin Anesth 1991; 3(3): 229-34.</mixed-citation>
                    </ref>
                            </ref-list>
                    </back>
    </article>