Research Article

EXAMINING THE EFFECT OF GENERATOR LOAD SHARING PRACTICES ON GREENHOUSE GAS EMISSIONS FOR A SHIP

Volume: 10 Number: 2 June 1, 2022
EN TR

EXAMINING THE EFFECT OF GENERATOR LOAD SHARING PRACTICES ON GREENHOUSE GAS EMISSIONS FOR A SHIP

Abstract

In this paper, the issue of efficient operation of generators, which is one of the energy efficiency parameters in ship electricity systems, is discussed in terms of greenhouse gas emissions. In order to meet the same power needs on a bulk carrier ship, three different load sharing situations are assessed in which the other generator is run synchronously when the active generators reach 40%, 60%, and 80% load ratios. Thus, CO2, CH4, and N2O emissions from generators for each practice are analyzed depending on fuel consumption. The results show that emissions vary for certain power needs in each situation. Also, there was no change in emissions for some power needs in three situations. In addition, it was estimated that up to 22% emission reductions could be achieved, depending on the power needs of the ship, if the generators were run at an 80% load ratio instead of 40%.

Keywords

References

  1. Başhan, V., Demirel, H., 2018, “Evaluation of critical operational faults of marine diesel generator engines by using DEMATEL method”, Journal of ETA Maritime Science, 6(2), 119-128.
  2. Başhan, V., Çakır, M., Sönmez, H.İ., 2018, “Bir dökme yük gemisi kreyn operasyonunun maliyet etkinliği ve emisyon analizi”, Journal of Eta Maritime Science, 6(1), 27-36.
  3. Başhan, V., Kökkülünk, G., 2020, “Exergoeconomic and air emission analyses for marine refrigeration with waste heat recovery system: a case study”, Journal of Marine Engineering & Technology, 19(3), 147-160.
  4. Cuculić, A., Ćelić, J., Prenc, R., 2016, “Marine diesel-generator model for voltage and frequency variation analysis during fault scenarios”, Pomorski zbornik, 51(1), 11-24.
  5. EEA, 2019, European Environment Agency, EMEP/EEA Air pollutant emission inventory guidebook 2019, https://www.eea.europa.eu/publications/emep-eea-guidebook-2019 (access date: 12 November 2021).
  6. Ekmekçioğlu, A., 2019, “Ship emission estimation for Izmir and Mersin international ports–Turkey”, Journal of Thermal Engineering, 5(6), 184-195.
  7. Fan, A., Yan, X., Bucknall, R., Yin, Q., Ji, S., Liu, Y., ... Chen, X., 2020, “A novel ship energy efficiency model considering random environmental parameters”, Journal of Marine Engineering & Technology, 19(4), 215-228.
  8. Gan, L.K., Shek, J.K., Mueller, M.A., 2015, “Hybrid wind–photovoltaic–diesel–battery system sizing tool development using empirical approach, life-cycle cost and performance analysis: A case study in Scotland”, Energy Conversion and Management, 106, 479-494.

Details

Primary Language

English

Subjects

Engineering

Journal Section

Research Article

Publication Date

June 1, 2022

Submission Date

January 11, 2022

Acceptance Date

March 4, 2022

Published in Issue

Year 2022 Volume: 10 Number: 2

APA
Yiğit, K. (2022). EXAMINING THE EFFECT OF GENERATOR LOAD SHARING PRACTICES ON GREENHOUSE GAS EMISSIONS FOR A SHIP. Konya Journal of Engineering Sciences, 10(2), 301-311. https://doi.org/10.36306/konjes.1056500
AMA
1.Yiğit K. EXAMINING THE EFFECT OF GENERATOR LOAD SHARING PRACTICES ON GREENHOUSE GAS EMISSIONS FOR A SHIP. KONJES. 2022;10(2):301-311. doi:10.36306/konjes.1056500
Chicago
Yiğit, Kenan. 2022. “EXAMINING THE EFFECT OF GENERATOR LOAD SHARING PRACTICES ON GREENHOUSE GAS EMISSIONS FOR A SHIP”. Konya Journal of Engineering Sciences 10 (2): 301-11. https://doi.org/10.36306/konjes.1056500.
EndNote
Yiğit K (June 1, 2022) EXAMINING THE EFFECT OF GENERATOR LOAD SHARING PRACTICES ON GREENHOUSE GAS EMISSIONS FOR A SHIP. Konya Journal of Engineering Sciences 10 2 301–311.
IEEE
[1]K. Yiğit, “EXAMINING THE EFFECT OF GENERATOR LOAD SHARING PRACTICES ON GREENHOUSE GAS EMISSIONS FOR A SHIP”, KONJES, vol. 10, no. 2, pp. 301–311, June 2022, doi: 10.36306/konjes.1056500.
ISNAD
Yiğit, Kenan. “EXAMINING THE EFFECT OF GENERATOR LOAD SHARING PRACTICES ON GREENHOUSE GAS EMISSIONS FOR A SHIP”. Konya Journal of Engineering Sciences 10/2 (June 1, 2022): 301-311. https://doi.org/10.36306/konjes.1056500.
JAMA
1.Yiğit K. EXAMINING THE EFFECT OF GENERATOR LOAD SHARING PRACTICES ON GREENHOUSE GAS EMISSIONS FOR A SHIP. KONJES. 2022;10:301–311.
MLA
Yiğit, Kenan. “EXAMINING THE EFFECT OF GENERATOR LOAD SHARING PRACTICES ON GREENHOUSE GAS EMISSIONS FOR A SHIP”. Konya Journal of Engineering Sciences, vol. 10, no. 2, June 2022, pp. 301-1, doi:10.36306/konjes.1056500.
Vancouver
1.Kenan Yiğit. EXAMINING THE EFFECT OF GENERATOR LOAD SHARING PRACTICES ON GREENHOUSE GAS EMISSIONS FOR A SHIP. KONJES. 2022 Jun. 1;10(2):301-1. doi:10.36306/konjes.1056500

Cited By