BibTex RIS Kaynak Göster

Monitorization in Small Animals

Yıl 2013, Cilt: 6 Sayı: 2, 45 - 55, 01.06.2013
https://doi.org/10.5578/kvj.5784

Öz

The purpose of the anesthesia is to provide reversible unconsciousness, amnesia, analgesia and immobilisation with minimum risk. However anesthetic drugs and additives disturb homeostasis of the patient unexpectedly. A sudden crisis during anesthesia unfortunately can make the patient’s life in danger. From this aspect the purpose of the monitorization is providing continuous data about organ functions and vital values maintaining anesthesia safety at the highest level, and decreasing anesthesia risks to minimum. In this review it is aimed to give recent knowledge about small animals vital parameter monitorization in veterinary surgery

Kaynakça

  • Backer D, Creteur J, Vincent JL. 2000. Use of orthogonal polarization spectral imaging in intensive care. In: Messmer K (ed). Orthogonal Polarization Spectral Imaging. Proggress in Applied Microcirculation. Basel, Karger, Volume 24,Pp:104-9.
  • Berton C, Cholley B, 2002. Equipment review: New techniques measurement-oesophageal Doppler, Fick principle using carbondioxide, and pulse contour analysis. Critical Care 2002;6:216-21.
  • Bland MJ, Altman DJ, 1986. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet ; 1:307-10.
  • Boldt J. 2002. Clinical review: Hemodynamic monitoring in the intensive care unit. Critical Care.6:52-9.
  • Dobb GJ and Donavan KD. 1987. Non-invasive methods of measuring cardiac output. Intensive Care Med. 13:304-9.
  • Esener Z, 1991. KLİNİK ANESTEZİ. LogosYayıncılık, İstanbul.
  • Gomersall CD., Joynt GM, Freebaırn RC, Hung V, Buckley TA., 2000. Resuscitation of critically ill patients based on the results of gastric tonometry: A prospective, randomized, controlled therapy. Crit Care Med 28:607-14.
  • Güler T, 2006. Monitörizasyon, Erişim: (http://lokman.cu.edu.tr/anestezi/anestezino t/newpage31.htm) Erişim Tarihi: 13.04.2013
  • Hanedan B, Kurtdede A, 2006. Enteritisli köpeklerde metabolik asidozisin mikro CO2 sistemi ile ölçümü ve sağaltımı, Ankara Üniv Vet Fak Derg, 53, 123-127.
  • Haskins SC, 1996. Monitoring The Anaesthetized Patients. Chapter 15: Lump and Jones’ Veterinary THURMON ve ark. Williams and Wilkins Co. U.S.A. p.: 409-424. Third Ed.Ed:
  • Heerden PV, Baker S, Lim SI, Weidman C, Bulsara M, 2000. Clinical evaluation of the non-invasive cardiac output (NICO) monitor in the intensive care unit. Anaesth Intensive Care. 28:427-30. Kılıç YA, 2005. Sepsiste Monitörizasyon ve Resüsitasyon, Yoğun Bakım Dergisi 5(2), 92-102 Hemodinamik
  • Koç B. 1996. Veteriner Anesteziyoloji ve Reanimasyon. Öğrenci Ders Notları, AÜ. Vet. Fak. ANKARA.
  • Koç B, Sarıtaş ZK, Şener O, 2012. Veteriner Anesteziyoloji ve Reanimasyon. (İkinci baskı). Medipres Matbaacılık Ltd. Şti. Malatya.
  • Köksal GM, 2010. İnvaziv monitörizasyon, Anesteziyoloji ve Reanimasyon AD. Öğrenci Ders Notları, İstanbul Üniversitesi.
  • Maxwell RA, Gibson JB, Slade JB, Fabian TC, Proctor KG, 2001. Noninvasive cardiac output by partial CO2 rebreathing after severe chest trauma. J Trauma. 51:849-53.
  • Mesmer K, 2000. Orthogonal Polarization Spectral Imaging. A new tool for the observation and measurement of the human microcirculation. Progress in Applied Microcirculation. Basel, Karger, Volume 24.
  • Morgan GE, Mikhail MS, Murray MJ, 1992. Clinical Anesthesiology. First Edition. Prentice-Hall International Inc.
  • Perk C, 2000. Monitorizasyon yöntemleri. İstanbul Veteriner Hekimler Odası Dergisi. 2, (2): 32 – 36
  • Sarıtaş Z, 1996. Köpeklerde Hemodinamik Monitorizasyon. AÜ Sağ. Bil. Enst. Seminer.
  • Sarıtaş Z, Koç B, Akın F, 1999. Köpeklerde balon tipi swan-ganz termodilüsyon kateteri ile pulmoner arter (sağ kalp) kateterizasyonu (108 olgu). Vet. Cer. Der. 5(1-2): 28-34
  • Skarada RT, Bednarsky RM, Muir WW, Hubbel JAE, 1995. Handbook of Veterinary Anesthesia, “Patient Monitoring During Anesthesia”, Philadelphia, London, Madrid, p.: 227 – 260.
  • Thomas WP, Sisssion D, 1999. Canine and Feline Cardiology, “Cardiac Catheterization and Angiocardiography” Philadelphia, London, Toronto, Sydney, Tokyo, p.: 173 – 192.
  • Tilley LP, Smith FWK. 2011. The 5 Minute Veterinary Consult. Canine and Feline, (Fifth edition). John Wiley & Sons Inc.
  • Valtier B, Cholley BP, Belot J, Coussave J, Mateo J, Payen D, 1998. Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler. Am J Respir Crit Care Med. 158:77-83.

Küçük Hayvanlarda Monitörizasyon

Yıl 2013, Cilt: 6 Sayı: 2, 45 - 55, 01.06.2013
https://doi.org/10.5578/kvj.5784

Öz

Anestezinin amacı hastaya en az riskle geri dönüşümlü bilinçsizlik, amnezi, analjezi ve hareketsizlik sağlamaktır. Ancak anestezik ilaçlar ve yardımcı maddeler, beklenmedik zamanlarda ve beklenmedik şekilde hastanın homeostasis’ini bozabilirler. Anestezi sırasında gelişebilecek ani bir kriz, ne yazık ki hastayı hayati bir tehlikeye sokabilir. Bu açıdan monitörizasyonun amacı organ fonksiyonları ve vital değerler hakkında sürekli bilgi akışı sağlayarak anestezinin güvenliğini en yüksek seviyede tutmak ve anestezinin risklerini en aza indirmektir. Bu derlemede Veteriner Cerrahide Küçük hayvanlarda vital parametrelerin monitörizasyonu hakkında güncel bilgiler vermek amaçlanmıştır

Kaynakça

  • Backer D, Creteur J, Vincent JL. 2000. Use of orthogonal polarization spectral imaging in intensive care. In: Messmer K (ed). Orthogonal Polarization Spectral Imaging. Proggress in Applied Microcirculation. Basel, Karger, Volume 24,Pp:104-9.
  • Berton C, Cholley B, 2002. Equipment review: New techniques measurement-oesophageal Doppler, Fick principle using carbondioxide, and pulse contour analysis. Critical Care 2002;6:216-21.
  • Bland MJ, Altman DJ, 1986. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet ; 1:307-10.
  • Boldt J. 2002. Clinical review: Hemodynamic monitoring in the intensive care unit. Critical Care.6:52-9.
  • Dobb GJ and Donavan KD. 1987. Non-invasive methods of measuring cardiac output. Intensive Care Med. 13:304-9.
  • Esener Z, 1991. KLİNİK ANESTEZİ. LogosYayıncılık, İstanbul.
  • Gomersall CD., Joynt GM, Freebaırn RC, Hung V, Buckley TA., 2000. Resuscitation of critically ill patients based on the results of gastric tonometry: A prospective, randomized, controlled therapy. Crit Care Med 28:607-14.
  • Güler T, 2006. Monitörizasyon, Erişim: (http://lokman.cu.edu.tr/anestezi/anestezino t/newpage31.htm) Erişim Tarihi: 13.04.2013
  • Hanedan B, Kurtdede A, 2006. Enteritisli köpeklerde metabolik asidozisin mikro CO2 sistemi ile ölçümü ve sağaltımı, Ankara Üniv Vet Fak Derg, 53, 123-127.
  • Haskins SC, 1996. Monitoring The Anaesthetized Patients. Chapter 15: Lump and Jones’ Veterinary THURMON ve ark. Williams and Wilkins Co. U.S.A. p.: 409-424. Third Ed.Ed:
  • Heerden PV, Baker S, Lim SI, Weidman C, Bulsara M, 2000. Clinical evaluation of the non-invasive cardiac output (NICO) monitor in the intensive care unit. Anaesth Intensive Care. 28:427-30. Kılıç YA, 2005. Sepsiste Monitörizasyon ve Resüsitasyon, Yoğun Bakım Dergisi 5(2), 92-102 Hemodinamik
  • Koç B. 1996. Veteriner Anesteziyoloji ve Reanimasyon. Öğrenci Ders Notları, AÜ. Vet. Fak. ANKARA.
  • Koç B, Sarıtaş ZK, Şener O, 2012. Veteriner Anesteziyoloji ve Reanimasyon. (İkinci baskı). Medipres Matbaacılık Ltd. Şti. Malatya.
  • Köksal GM, 2010. İnvaziv monitörizasyon, Anesteziyoloji ve Reanimasyon AD. Öğrenci Ders Notları, İstanbul Üniversitesi.
  • Maxwell RA, Gibson JB, Slade JB, Fabian TC, Proctor KG, 2001. Noninvasive cardiac output by partial CO2 rebreathing after severe chest trauma. J Trauma. 51:849-53.
  • Mesmer K, 2000. Orthogonal Polarization Spectral Imaging. A new tool for the observation and measurement of the human microcirculation. Progress in Applied Microcirculation. Basel, Karger, Volume 24.
  • Morgan GE, Mikhail MS, Murray MJ, 1992. Clinical Anesthesiology. First Edition. Prentice-Hall International Inc.
  • Perk C, 2000. Monitorizasyon yöntemleri. İstanbul Veteriner Hekimler Odası Dergisi. 2, (2): 32 – 36
  • Sarıtaş Z, 1996. Köpeklerde Hemodinamik Monitorizasyon. AÜ Sağ. Bil. Enst. Seminer.
  • Sarıtaş Z, Koç B, Akın F, 1999. Köpeklerde balon tipi swan-ganz termodilüsyon kateteri ile pulmoner arter (sağ kalp) kateterizasyonu (108 olgu). Vet. Cer. Der. 5(1-2): 28-34
  • Skarada RT, Bednarsky RM, Muir WW, Hubbel JAE, 1995. Handbook of Veterinary Anesthesia, “Patient Monitoring During Anesthesia”, Philadelphia, London, Madrid, p.: 227 – 260.
  • Thomas WP, Sisssion D, 1999. Canine and Feline Cardiology, “Cardiac Catheterization and Angiocardiography” Philadelphia, London, Toronto, Sydney, Tokyo, p.: 173 – 192.
  • Tilley LP, Smith FWK. 2011. The 5 Minute Veterinary Consult. Canine and Feline, (Fifth edition). John Wiley & Sons Inc.
  • Valtier B, Cholley BP, Belot J, Coussave J, Mateo J, Payen D, 1998. Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler. Am J Respir Crit Care Med. 158:77-83.
Toplam 24 adet kaynakça vardır.

Ayrıntılar

Birincil Dil Türkçe
Bölüm Makaleler
Yazarlar

Zülfikar Kadir Sarıtaş Bu kişi benim

Berk Alp Göksel Bu kişi benim

Yayımlanma Tarihi 1 Haziran 2013
Yayımlandığı Sayı Yıl 2013 Cilt: 6 Sayı: 2

Kaynak Göster

APA Sarıtaş, Z. K., & Göksel, B. A. (2013). Küçük Hayvanlarda Monitörizasyon. Kocatepe Veterinary Journal, 6(2), 45-55. https://doi.org/10.5578/kvj.5784
AMA Sarıtaş ZK, Göksel BA. Küçük Hayvanlarda Monitörizasyon. kvj. Haziran 2013;6(2):45-55. doi:10.5578/kvj.5784
Chicago Sarıtaş, Zülfikar Kadir, ve Berk Alp Göksel. “Küçük Hayvanlarda Monitörizasyon”. Kocatepe Veterinary Journal 6, sy. 2 (Haziran 2013): 45-55. https://doi.org/10.5578/kvj.5784.
EndNote Sarıtaş ZK, Göksel BA (01 Haziran 2013) Küçük Hayvanlarda Monitörizasyon. Kocatepe Veterinary Journal 6 2 45–55.
IEEE Z. K. Sarıtaş ve B. A. Göksel, “Küçük Hayvanlarda Monitörizasyon”, kvj, c. 6, sy. 2, ss. 45–55, 2013, doi: 10.5578/kvj.5784.
ISNAD Sarıtaş, Zülfikar Kadir - Göksel, Berk Alp. “Küçük Hayvanlarda Monitörizasyon”. Kocatepe Veterinary Journal 6/2 (Haziran 2013), 45-55. https://doi.org/10.5578/kvj.5784.
JAMA Sarıtaş ZK, Göksel BA. Küçük Hayvanlarda Monitörizasyon. kvj. 2013;6:45–55.
MLA Sarıtaş, Zülfikar Kadir ve Berk Alp Göksel. “Küçük Hayvanlarda Monitörizasyon”. Kocatepe Veterinary Journal, c. 6, sy. 2, 2013, ss. 45-55, doi:10.5578/kvj.5784.
Vancouver Sarıtaş ZK, Göksel BA. Küçük Hayvanlarda Monitörizasyon. kvj. 2013;6(2):45-5.

13520    13521       13522   1352314104