Araştırma Makalesi
BibTex RIS Kaynak Göster

Serum copper measurement-using aas containing graphite tube

Yıl 1991, Cilt: 4 Sayı: 4, 136 - 140, 01.12.1991

Öz

The aim of this study was to establish the best method to measure copper (Cu) in serum using the atomic absorption spectrometry (AAS) apparatus (Rank Hilger, H 1550 type, Westwood Margate Kent CT9 4JL- England) with graphite tube. We compared the "standard curve" and the "extrapolation" methods and found for n=25, X±SD, SE as 78.2±0.07, 0.25 and 82.7±0.11, 0.35 pg/dL, respectively. There was not statistically any significant difference between them. In the end, because the standard curve was linear, recovery values and precision evaluations were better, the accuracy of the standard curve method was accepted to be good. In addition, it is a rapid and easily performed method, and is well suited for routine analysis of Cu in a clinical laboratory.

Kaynakça

  • Evenson MA, Warren BL. Determination of serum copper by atomic absorption, with use of the graphite cuvette. Clin Chem 1975; 21: 619-25.
Yıl 1991, Cilt: 4 Sayı: 4, 136 - 140, 01.12.1991

Öz

Kaynakça

  • Evenson MA, Warren BL. Determination of serum copper by atomic absorption, with use of the graphite cuvette. Clin Chem 1975; 21: 619-25.
Toplam 1 adet kaynakça vardır.

Ayrıntılar

Konular Klinik Tıp Bilimleri
Bölüm Editör'den
Yazarlar

A.h. Güler Bu kişi benim

E. Salantur Bu kişi benim

B. Ediz Bu kişi benim

Yayımlanma Tarihi 1 Aralık 1991
Yayımlandığı Sayı Yıl 1991 Cilt: 4 Sayı: 4

Kaynak Göster

APA Güler, A., Salantur, E., & Ediz, B. (1991). Serum copper measurement-using aas containing graphite tube. Marmara Medical Journal, 4(4), 136-140.
AMA Güler A, Salantur E, Ediz B. Serum copper measurement-using aas containing graphite tube. Marmara Med J. Aralık 1991;4(4):136-140.
Chicago Güler, A.h., E. Salantur, ve B. Ediz. “Serum Copper Measurement-Using Aas Containing Graphite Tube”. Marmara Medical Journal 4, sy. 4 (Aralık 1991): 136-40.
EndNote Güler A, Salantur E, Ediz B (01 Aralık 1991) Serum copper measurement-using aas containing graphite tube. Marmara Medical Journal 4 4 136–140.
IEEE A. Güler, E. Salantur, ve B. Ediz, “Serum copper measurement-using aas containing graphite tube”, Marmara Med J, c. 4, sy. 4, ss. 136–140, 1991.
ISNAD Güler, A.h. vd. “Serum Copper Measurement-Using Aas Containing Graphite Tube”. Marmara Medical Journal 4/4 (Aralık 1991), 136-140.
JAMA Güler A, Salantur E, Ediz B. Serum copper measurement-using aas containing graphite tube. Marmara Med J. 1991;4:136–140.
MLA Güler, A.h. vd. “Serum Copper Measurement-Using Aas Containing Graphite Tube”. Marmara Medical Journal, c. 4, sy. 4, 1991, ss. 136-40.
Vancouver Güler A, Salantur E, Ediz B. Serum copper measurement-using aas containing graphite tube. Marmara Med J. 1991;4(4):136-40.