Objective: Fast and accurate detection of fluid balance in intensive care patients is of special significance. Many different methods are
used to determine the fluid balance. In this study, we aimed to determine the fluid balance of patients in the medical intensive care
unit using measurement of the inferior vena cava diameter and pro-brain natriuretic peptide (proBNP).
Patients and Methods: Patients admitted to the medical intensive care unit between September 2013 and February 2014 were enrolled
in the study. Inferior vena cava diameter was measured with a portable ultrasonography, according to guidelines published by the
American Echocardiography Association. For pro BNP measurement, samples were taken simultaneously with ultrasonography.
Results: One hundred and twenty-six patients (70 male,55.6%) were enrolled for the study. Mean age was 57.8 ± 19.8 (18-89 years).
Nintey six (76.2%) patients were receiving mechanical ventilation support. Mean proBNP levels were 10645.88 ± 12731.08 pg/ml.
There was no statistically significant difference between proBNP levels in patients according to the fluid status. Collapsibility index
was not statistically different according to the volume status (p=0.75).
Conclusion: proBNP levels were not correlated with the fluid balance. proBNP levels and inferior vena cava diameters were negatively
but weakly correlated.
Fluid balance Inferior vena cava diameter proBNP Ultrasonography
Birincil Dil | İngilizce |
---|---|
Konular | Klinik Tıp Bilimleri |
Bölüm | Original Articles |
Yazarlar | |
Yayımlanma Tarihi | 29 Ocak 2021 |
Yayımlandığı Sayı | Yıl 2021 Cilt: 34 Sayı: 1 |