Research Article

Modelling, Sensitivity and Exergy Analysis of Triple-Pressure Heat Recovery Steam Generator

Volume: 8 Number: 2 December 21, 2020
EN

Modelling, Sensitivity and Exergy Analysis of Triple-Pressure Heat Recovery Steam Generator

Abstract

Combined with the increasing demand for environmental pollution and electrical energy, combined cycle power plant power plants are increasingly important. It is necessary to increase the performance of power plants, reduce carbon emissions and increase energy production. Any change to the heat recovery steam generator design is an important component of the combined cycle power plant, as it directly affects the performance of the combined cycle power plant. This study describes the modeling, sensitivity and exergy analysis of a HRSG in a combined cycle power plant. Three-pressure HRSG was modeled with the Aspen Plus simulation program and sensitivity analysis was performed. At the same time, energy and exergy analyzes were made for each component in the combined cycle power plant.

Keywords

exergy analysis, aspen plus, Heat Recovery Steam Generator, Sensitivity Analysis, Combined Cycle Power Plant

References

  1. Kole A., "A review and study on advanced control and automation functions and future control for a modern combined cycle power plant", 2016 International Conference on Intelligent Control, Power and Instrumentation, (2017), 215-220.
  2. Rackley S.A., "Carbon capture from power generation. In: Carbon Capture and Storage" (2017).
  3. Nadir M., Ghenaiet A., "Thermodynamic optimization of several (heat recovery steam generator) HRSG configurations for a range of exhaust gas temperatures" Energy, (2015),685-695.
  4. Dumont M.N., Heyen G., "Mathematical modelling and design of an advanced once-through heat recovery steam generator", Computers and Chemical Engineering, (2004),651-660.
  5. Feng H., Zhong W., Wu Y., Tong S., "Thermodynamic performance analysis and algorithm model of multi-pressure heat recovery steam generators (HRSG) based on heat exchangers layout", Energy Convers Manag, (2014), 282-289.
  6. Durán M.D., Valdés M., Rovira A., Rincón E., "A methodology for the geometric design of heat recovery steam generators applying genetic algorithm". Appl Therm Eng, (2013),77-83.
  7. Naemi S., Saffar A.M., Behboodi K.S., Mansoori Z., "Optimum design of dual pressure heat recovery steam generator using non-dimensional parameters based on thermodynamic and thermoeconomic approaches" Appl Therm Eng, (2013), 371-384.
  8. Mohammadi K.A., Joda F., Bozorgmehry R., "Exergic, economic and environmental impacts of natural gas and diesel in operation of combined cycle power plants", Energy Convers Manag, (2016), 103-112.
  9. Manassaldi J.I., Arias A.M., Scenna N.J., Mussati M.C., Mussati S.F., "A discrete and continuous mathematical model for the optimal synthesis and design of dual pressure heat recovery steam generators coupled to two steam turbines", Energy, (2016), 807-823.
  10. Martelli E., Elsido C., Mian A., Marechal F., "MINLP model and two-stage algorithm for the simultaneous synthesis of heat exchanger networks, utility systems and heat recovery cycles", Comput Chem Eng, (2017), 663-689.
APA
Mert, S. O., Özçelik, F. Z., & Kök, C. (2020). Modelling, Sensitivity and Exergy Analysis of Triple-Pressure Heat Recovery Steam Generator. MANAS Journal of Engineering, 8(2), 106-114. https://doi.org/10.51354/mjen.793611
AMA
1.Mert SO, Özçelik FZ, Kök C. Modelling, Sensitivity and Exergy Analysis of Triple-Pressure Heat Recovery Steam Generator. MJEN. 2020;8(2):106-114. doi:10.51354/mjen.793611
Chicago
Mert, Suha Orçun, F. Zehra Özçelik, and Ceyda Kök. 2020. “Modelling, Sensitivity and Exergy Analysis of Triple-Pressure Heat Recovery Steam Generator”. MANAS Journal of Engineering 8 (2): 106-14. https://doi.org/10.51354/mjen.793611.
EndNote
Mert SO, Özçelik FZ, Kök C (December 1, 2020) Modelling, Sensitivity and Exergy Analysis of Triple-Pressure Heat Recovery Steam Generator. MANAS Journal of Engineering 8 2 106–114.
IEEE
[1]S. O. Mert, F. Z. Özçelik, and C. Kök, “Modelling, Sensitivity and Exergy Analysis of Triple-Pressure Heat Recovery Steam Generator”, MJEN, vol. 8, no. 2, pp. 106–114, Dec. 2020, doi: 10.51354/mjen.793611.
ISNAD
Mert, Suha Orçun - Özçelik, F. Zehra - Kök, Ceyda. “Modelling, Sensitivity and Exergy Analysis of Triple-Pressure Heat Recovery Steam Generator”. MANAS Journal of Engineering 8/2 (December 1, 2020): 106-114. https://doi.org/10.51354/mjen.793611.
JAMA
1.Mert SO, Özçelik FZ, Kök C. Modelling, Sensitivity and Exergy Analysis of Triple-Pressure Heat Recovery Steam Generator. MJEN. 2020;8:106–114.
MLA
Mert, Suha Orçun, et al. “Modelling, Sensitivity and Exergy Analysis of Triple-Pressure Heat Recovery Steam Generator”. MANAS Journal of Engineering, vol. 8, no. 2, Dec. 2020, pp. 106-14, doi:10.51354/mjen.793611.
Vancouver
1.Suha Orçun Mert, F. Zehra Özçelik, Ceyda Kök. Modelling, Sensitivity and Exergy Analysis of Triple-Pressure Heat Recovery Steam Generator. MJEN. 2020 Dec. 1;8(2):106-14. doi:10.51354/mjen.793611