Araştırma Makalesi
BibTex RIS Kaynak Göster

Experimental evaluation of water source heat pump by Taguchi method

Yıl 2024, Cilt: 4 Sayı: 1, 11 - 22, 30.06.2024
https://doi.org/10.5281/zenodo.12547609

Öz

Water source heat pumps are devices that can produce heating or cooling in the place using the energy in the ambient water which serves as the easiest source of heat. The heat pumps, which utilize the ambient water on the boiling side, are able to transfer the energy they have obtained to the water or air on the load side. The renewable geothermal energy, which is produced by the alternative energy sources, is also an important potential in Turkey as a sustainable and environmental- friendly source. The subject of utilizing geothermal energy has been among the most balanced and high efficiency, low maintenance comfortable energy sources in pace with the technological developments of the heat pumps. The widespread and daily use of the ground source heat pumps and the examination of the situation in Turkey lead us to the determination of the potential applicability which is one of the important issues. In this study, the COP of various parameters and different levels of the water source heat pumps were calculated according to the Taguchi experiment design.

Kaynakça

  • 1. Acuña J, Palm B. A novel coaxial borehole heat exchanger: description and first distributed thermal response test measurements. In: Proceedings of the World Geothermal Congress; 2010; Bali, Indonesia. 2010.
  • 2. Develioğlu, M. Yer Kaynaklı Isı Pompalarının Teknolojik Gelişimi ve Türkiye'deki Uygulanabilirliği. [MS thesis]. Fen Bilimleri Enstitüsü, Hacettepe University, 2012.
  • 3. Unlu K. Hava ve toprak kaynaklı ısı pompalarına etki eden parametrelerin incelenmesi. [PhD thesis]. Bursa Uludağ University; 2005.
  • 4. Ajah A, Mesbah A, Grievink J, Herder P, Falcao P, Wennekes S. On the robustness, effectiveness and reliability of chemical and mechanical heat pumps for low-temperature heat source district heating: A comparative simulation-based analysis and evaluation. Energy. 2008;33(6):908-929. doi:10.1016/j.energy.2007.12.003
  • 5. Bendell A, Disney J, Pridmore WA. Taguchi Methods. New York, NY: Springer-Verlag; 1989.
  • 6. Baek NC, Shin UC, Yoon JH. A study on the design and analysis of a heat pump heating system using wastewater as a heat source. Sol Energy. 2005;78(3):427-440. doi:10.1016/j.solener.2004.07.009
  • 7. Purkayastha B, Bansal PK. An experimental study on HC290 and a commercial liquefied petroleum gas (LPG) mix as suitable replacements for HCFC22. Int J Refrig. 1998;21(1):3-17. doi:10.1016/s0140-7007(97)00083-2
  • 8. Can M. Endüstriyel atık akışkanların değerlendirilmesi ve ülke ekonomisine katkısı. Ekoloji Dergisi. 1995;17: Ekim, Kasım, Aralık.
  • 9. McMullan JT. Refrigeration and the environment — issues and strategies for the future. Int J Refrig. 2002;25(1):89-99. doi:10.1016/s0140-7007(01)00007-x
  • 10. Huang K, Wang H, Zhou X. Heat pump for high school bathroom heat recovery. Renew. Energy Resour. Greenery Future. 2006;8(12-1):1-6.
  • 11. Correa G, Almanza R. Copper based thin films to improve glazing for energy-savings in buildings. Sol Energy. 2004;76(1-3):111-115. doi:10.1016/j.solener.2003.08.014
  • 12. Kotcioglu I, Cansiz A, Khalaji MN. Experimental investigation for optimization of design parameters in a rectangular duct with plate-fins heat exchanger by Taguchi method. Appl Therm Eng. 2013;50(1):604-613. doi:10.1016/j.applthermaleng.2012.05.036
  • 13. Kotcioglu I, Khalaji MN, Cansiz A. Heat transfer analysis of a rectangular channel having tubular router in different winglet configurations with Taguchi method. Appl Therm Eng. 2018;132:637-650. doi:10.1016/j.applthermaleng.2017.12.120
  • 14. Yu X, Wang RZ, Zhai XQ. Year round experimental study on a constant temperature and humidity air-conditioning system driven by ground source heat pump. Energy. 2011;36(2):1309-1318. doi:10.1016/j.energy.2010.11.013
  • 15. Lazzarin RM. Heat pumps in industry II: Applications. Heat Recov Syst CHP. 1995;15(3):305-317. doi:10.1016/0890-4332(95)90014-4
  • 16. Nuntaphan A, Chansena C, Kiatsiriroat T. Performance analysis of solar water heater combined with heat pump using refrigerant mixture. Appl Energy. 2009;86(5):748-756. doi:10.1016/j.apenergy.2008.05.014
  • 17. Sen M, Yang KT. Applications of artificial neural networks and genetic algorithms in thermal engineering. CRC Handbook of Thermal Engineering. 2000:620-661.
  • 18. Chen C, Sun FL, Feng L, Liu M. Underground water-source loop heat-pump air-conditioning system applied in a residential building in Beijing. Appl Energy. 2005;82(4):331-344. doi:10.1016/j.apenergy.2004.12.002
  • 19. Park KJ, Shim YB, Jung D. Performance of R433A for replacing HCFC22 used in residential air-conditioners and heat pumps. Appl Energy. 2008;85(9):896-900. doi:10.1016/j.apenergy.2007.11.003
  • 20. Medrano M, Bourouis M, Coronas A. Double-lift absorption refrigeration cycles driven by low–temperature heat sources using organic fluid mixtures as working pairs. Appl Energy. 2001;68(2):173-185. doi:10.1016/s0306-2619(00)00048-9
  • 21. Koo KM, Jeong YM, Hwang YJ, Lee JK, Jang SY, Kim IK, Lee DH. Heating performance of a ground source heat pump systemthrough actual operation. Proceedingsofthe SAREK Conference. The Society of Air-Conditioning and Refrigerating Engineers of Korea; 2008.
  • 22. Yamazaki T, Kubo Y. Development of a high-temperature heat pump. Newsl IEA Heat Pump Cent. 1985;3(4):18-21.
  • 23. Pinar AM, Uluer O, Kırmaci V. Optimization of counter flow Ranque–Hilsch vortex tube performance using Taguchi method. Int J Refrig. 2009;32(6):1487-1494. doi:10.1016/j.ijrefrig.2009.02.018
  • 24. Yun JY, Lee KS. Influence of design parameters on the heat transfer and flow friction characteristics of the heat exchanger with slit fins. Int J Heat Mass Transfer. 2000;43(14):2529-2539. doi:10.1016/s0017-9310(99)00342-7
  • 25. Nakayama W. A methodology to work on geometrically complex heat transfer systems: the cases of heat conduction through composite slabs. Int J Heat Mass Transfer. 2003;46(18):3397-3409. doi:10.1016/s0017-9310(03)00136-4
  • 26. Williamson SS, Emadi A. Comparative Assessment of Hybrid Electric and Fuel Cell Vehicles Based on Comprehensive Well-to-Wheels Efficiency Analysis. IEEE Trans Veh Technol. 2005;54(3):856-862. doi:10.1109/tvt.2005.847444
  • 27. Li YL, Zhang XS, Yin YG. Studies on solid desiccant integrated natural gas engine-driven air conditioning system. Proceedings of the 10th International Conference on Indoor Air Quality and Climate, vols. 1–5. 2005:1279– 1283.
  • 28. Nam Y, Ooka R. Numerical simulation of ground heat and water transfer for groundwater heat pump system based on real-scale experiment. Energy Build. 2010;42(1):69-75. doi:10.1016/j.enbuild.2009.07.012
  • 29. Nam Y, Ooka R, Shiba Y. Development of dual-source hybrid heat pump system using groundwater and air. Energy Build. 2010;42(6):909-916. doi:10.1016/j.enbuild.2009.12.013
  • 30. Esme U. Application of Taguchi method for the optimization of resistance spot welding process. Arab J Sci Eng. 2009;34.
Yıl 2024, Cilt: 4 Sayı: 1, 11 - 22, 30.06.2024
https://doi.org/10.5281/zenodo.12547609

Öz

Kaynakça

  • 1. Acuña J, Palm B. A novel coaxial borehole heat exchanger: description and first distributed thermal response test measurements. In: Proceedings of the World Geothermal Congress; 2010; Bali, Indonesia. 2010.
  • 2. Develioğlu, M. Yer Kaynaklı Isı Pompalarının Teknolojik Gelişimi ve Türkiye'deki Uygulanabilirliği. [MS thesis]. Fen Bilimleri Enstitüsü, Hacettepe University, 2012.
  • 3. Unlu K. Hava ve toprak kaynaklı ısı pompalarına etki eden parametrelerin incelenmesi. [PhD thesis]. Bursa Uludağ University; 2005.
  • 4. Ajah A, Mesbah A, Grievink J, Herder P, Falcao P, Wennekes S. On the robustness, effectiveness and reliability of chemical and mechanical heat pumps for low-temperature heat source district heating: A comparative simulation-based analysis and evaluation. Energy. 2008;33(6):908-929. doi:10.1016/j.energy.2007.12.003
  • 5. Bendell A, Disney J, Pridmore WA. Taguchi Methods. New York, NY: Springer-Verlag; 1989.
  • 6. Baek NC, Shin UC, Yoon JH. A study on the design and analysis of a heat pump heating system using wastewater as a heat source. Sol Energy. 2005;78(3):427-440. doi:10.1016/j.solener.2004.07.009
  • 7. Purkayastha B, Bansal PK. An experimental study on HC290 and a commercial liquefied petroleum gas (LPG) mix as suitable replacements for HCFC22. Int J Refrig. 1998;21(1):3-17. doi:10.1016/s0140-7007(97)00083-2
  • 8. Can M. Endüstriyel atık akışkanların değerlendirilmesi ve ülke ekonomisine katkısı. Ekoloji Dergisi. 1995;17: Ekim, Kasım, Aralık.
  • 9. McMullan JT. Refrigeration and the environment — issues and strategies for the future. Int J Refrig. 2002;25(1):89-99. doi:10.1016/s0140-7007(01)00007-x
  • 10. Huang K, Wang H, Zhou X. Heat pump for high school bathroom heat recovery. Renew. Energy Resour. Greenery Future. 2006;8(12-1):1-6.
  • 11. Correa G, Almanza R. Copper based thin films to improve glazing for energy-savings in buildings. Sol Energy. 2004;76(1-3):111-115. doi:10.1016/j.solener.2003.08.014
  • 12. Kotcioglu I, Cansiz A, Khalaji MN. Experimental investigation for optimization of design parameters in a rectangular duct with plate-fins heat exchanger by Taguchi method. Appl Therm Eng. 2013;50(1):604-613. doi:10.1016/j.applthermaleng.2012.05.036
  • 13. Kotcioglu I, Khalaji MN, Cansiz A. Heat transfer analysis of a rectangular channel having tubular router in different winglet configurations with Taguchi method. Appl Therm Eng. 2018;132:637-650. doi:10.1016/j.applthermaleng.2017.12.120
  • 14. Yu X, Wang RZ, Zhai XQ. Year round experimental study on a constant temperature and humidity air-conditioning system driven by ground source heat pump. Energy. 2011;36(2):1309-1318. doi:10.1016/j.energy.2010.11.013
  • 15. Lazzarin RM. Heat pumps in industry II: Applications. Heat Recov Syst CHP. 1995;15(3):305-317. doi:10.1016/0890-4332(95)90014-4
  • 16. Nuntaphan A, Chansena C, Kiatsiriroat T. Performance analysis of solar water heater combined with heat pump using refrigerant mixture. Appl Energy. 2009;86(5):748-756. doi:10.1016/j.apenergy.2008.05.014
  • 17. Sen M, Yang KT. Applications of artificial neural networks and genetic algorithms in thermal engineering. CRC Handbook of Thermal Engineering. 2000:620-661.
  • 18. Chen C, Sun FL, Feng L, Liu M. Underground water-source loop heat-pump air-conditioning system applied in a residential building in Beijing. Appl Energy. 2005;82(4):331-344. doi:10.1016/j.apenergy.2004.12.002
  • 19. Park KJ, Shim YB, Jung D. Performance of R433A for replacing HCFC22 used in residential air-conditioners and heat pumps. Appl Energy. 2008;85(9):896-900. doi:10.1016/j.apenergy.2007.11.003
  • 20. Medrano M, Bourouis M, Coronas A. Double-lift absorption refrigeration cycles driven by low–temperature heat sources using organic fluid mixtures as working pairs. Appl Energy. 2001;68(2):173-185. doi:10.1016/s0306-2619(00)00048-9
  • 21. Koo KM, Jeong YM, Hwang YJ, Lee JK, Jang SY, Kim IK, Lee DH. Heating performance of a ground source heat pump systemthrough actual operation. Proceedingsofthe SAREK Conference. The Society of Air-Conditioning and Refrigerating Engineers of Korea; 2008.
  • 22. Yamazaki T, Kubo Y. Development of a high-temperature heat pump. Newsl IEA Heat Pump Cent. 1985;3(4):18-21.
  • 23. Pinar AM, Uluer O, Kırmaci V. Optimization of counter flow Ranque–Hilsch vortex tube performance using Taguchi method. Int J Refrig. 2009;32(6):1487-1494. doi:10.1016/j.ijrefrig.2009.02.018
  • 24. Yun JY, Lee KS. Influence of design parameters on the heat transfer and flow friction characteristics of the heat exchanger with slit fins. Int J Heat Mass Transfer. 2000;43(14):2529-2539. doi:10.1016/s0017-9310(99)00342-7
  • 25. Nakayama W. A methodology to work on geometrically complex heat transfer systems: the cases of heat conduction through composite slabs. Int J Heat Mass Transfer. 2003;46(18):3397-3409. doi:10.1016/s0017-9310(03)00136-4
  • 26. Williamson SS, Emadi A. Comparative Assessment of Hybrid Electric and Fuel Cell Vehicles Based on Comprehensive Well-to-Wheels Efficiency Analysis. IEEE Trans Veh Technol. 2005;54(3):856-862. doi:10.1109/tvt.2005.847444
  • 27. Li YL, Zhang XS, Yin YG. Studies on solid desiccant integrated natural gas engine-driven air conditioning system. Proceedings of the 10th International Conference on Indoor Air Quality and Climate, vols. 1–5. 2005:1279– 1283.
  • 28. Nam Y, Ooka R. Numerical simulation of ground heat and water transfer for groundwater heat pump system based on real-scale experiment. Energy Build. 2010;42(1):69-75. doi:10.1016/j.enbuild.2009.07.012
  • 29. Nam Y, Ooka R, Shiba Y. Development of dual-source hybrid heat pump system using groundwater and air. Energy Build. 2010;42(6):909-916. doi:10.1016/j.enbuild.2009.12.013
  • 30. Esme U. Application of Taguchi method for the optimization of resistance spot welding process. Arab J Sci Eng. 2009;34.
Toplam 30 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Konular Nanomalzemeler
Bölüm Research Articles
Yazarlar

Mansur Mustafaoğlu 0000-0003-2976-0196

Reza Matin 0000-0003-4471-0031

İsak Kotcioğlu 0000-0003-1890-772X

Muhammet Kaan Yeşilyurt 0000-0002-7207-1743

Erken Görünüm Tarihi 27 Haziran 2024
Yayımlanma Tarihi 30 Haziran 2024
Gönderilme Tarihi 31 Mayıs 2024
Kabul Tarihi 13 Haziran 2024
Yayımlandığı Sayı Yıl 2024 Cilt: 4 Sayı: 1

Kaynak Göster