EN
Can graphic tablets facilitate expedited and more accurate volume measurements?
Abstract
Volume measurements of organs and structures are crucial for medical assessments and have traditionally been performed using computers, with a recent interest in tablets with digital pens. This study aims to evaluate the reliability of the computer mouse and graphic tablet in organ volume measurements based on the Cavalieri Principle. It will compare the advantages and disadvantages of each device, focusing on consistency and measurement duration. The study analyzed a dataset comprising 22 abdominal CT images from females and 21 from males, sourced from the Department of Radiology. Spleen and kidney volumes were quantified using Image J software and the Cavalieri Principle, utilizing both a computer equipped with a mouse and a graphic tablet with a drawing pen. The results revealed that computer mouse and graphic tablet measurements showed similar organ volumes, with average kidney volumes of 181.53 ±51.72 cm³ and 179.34 ±51.37 cm³, respectively, and spleen volumes of 211.03 ±78.47 cm³ and 205.93 ±77.52 cm³, respectively. The computer mouse required 283.55 ±56.03 seconds for the kidney and 386.74 ±106.66 seconds for the spleen, whereas the graphic tablet took only 128.79 ±33.32 seconds for the kidney and 141.91 ±40.18 seconds for the spleen, demonstrating a statistically significant reduction in measurement time (p < 0.001). The findings of this study suggest that graphic tablet provides a comparable level of reliability to the computer mouse for organ volume measurements using the Cavalieri Principle. Additionally, the tablet offers the significant benefit of faster measurement times.
Keywords
References
- Jiang SM, Zhou GW, Shen C, Yan JQ, Wan L, Li QY, et al. [A clinical study on splanchnic hemodynamic changes after orthotopic liver transplantation for patients with portal hypertension]. Zhonghua Wai Ke Za Zhi. 2008;46(22):1699-702.
- Logsdon NT, Gallo CM, Pires RS, Sampaio FJ, Favorito LA. Prostate and testicular growth analysis in human fetuses during the second gestational trimester. Prostate. 2021;81(3):214-9.
- Parenteau CS, Ehrlich P, Ma L, Su GL, Holcombe S, Wang SC. The quantification of liver anatomical changes and assessment of occupant liver injury patterns. Stapp Car Crash J. 2013;57:267-83.
- Pate WR, Garg N, Wang LB, Wason SE, Barbosa PV. Comparison of Transabdominal and Transrectal Ultrasound for Sizing of the Prostate. Urology. 2020;141:125-9.
- Schiavon G, Ruggiero A, Schöffski P, van der Holt B, Bekers DJ, Eechoute K, et al. Tumor volume as an alternative response measurement for imatinib treated GIST patients. PLoS One. 2012;7(11):e48372.
- Odaci E, Bahadir A, Yildirim Ş, Şahin B, Canan S, Baş O, et al. Volume estimation using the cavalieri principle on computerized tomography and magnetic resonance images and its clinical application: Review Cavalieri prensibi kullanilarak bilgisayarli tomografi ve manyetik rezonans görüntüleri üzerinden hacim hesaplanmasi ve klinik kullanimi. Turkiye Klinikleri Journal of Medical Sciences. 2005;25(3).
- Canan S, Sahin B, Odaci E, Unal B, Aslan H, Bilgiç S, et al. Estimation of the reference volume, volume density and volume ratios by a stereological method: Cavalieri's principle. T Klin J Med Sci. 2002;22:7-14.
- Acer N, Sahin B, Ergür H, Basaloglu H, Ceri NG. Stereological estimation of the orbital volume: a criterion standard study. J Craniofac Surg. 2009;20(3):921-5.
Details
Primary Language
English
Subjects
Radiology and Organ Imaging
Journal Section
Research Article
Publication Date
May 19, 2024
Submission Date
March 12, 2024
Acceptance Date
April 4, 2024
Published in Issue
Year 2024 Volume: 41 Number: 2
APA
Nahir, M., & Şahin, B. (2024). Can graphic tablets facilitate expedited and more accurate volume measurements? Deneysel Ve Klinik Tıp Dergisi, 41(2), 233-238. https://izlik.org/JA59CJ54TX
AMA
1.Nahir M, Şahin B. Can graphic tablets facilitate expedited and more accurate volume measurements? J. Exp. Clin. Med. 2024;41(2):233-238. https://izlik.org/JA59CJ54TX
Chicago
Nahir, Mert, and Bünyamin Şahin. 2024. “Can Graphic Tablets Facilitate Expedited and More Accurate Volume Measurements?”. Deneysel Ve Klinik Tıp Dergisi 41 (2): 233-38. https://izlik.org/JA59CJ54TX.
EndNote
Nahir M, Şahin B (May 1, 2024) Can graphic tablets facilitate expedited and more accurate volume measurements? Deneysel ve Klinik Tıp Dergisi 41 2 233–238.
IEEE
[1]M. Nahir and B. Şahin, “Can graphic tablets facilitate expedited and more accurate volume measurements?”, J. Exp. Clin. Med., vol. 41, no. 2, pp. 233–238, May 2024, [Online]. Available: https://izlik.org/JA59CJ54TX
ISNAD
Nahir, Mert - Şahin, Bünyamin. “Can Graphic Tablets Facilitate Expedited and More Accurate Volume Measurements?”. Deneysel ve Klinik Tıp Dergisi 41/2 (May 1, 2024): 233-238. https://izlik.org/JA59CJ54TX.
JAMA
1.Nahir M, Şahin B. Can graphic tablets facilitate expedited and more accurate volume measurements? J. Exp. Clin. Med. 2024;41:233–238.
MLA
Nahir, Mert, and Bünyamin Şahin. “Can Graphic Tablets Facilitate Expedited and More Accurate Volume Measurements?”. Deneysel Ve Klinik Tıp Dergisi, vol. 41, no. 2, May 2024, pp. 233-8, https://izlik.org/JA59CJ54TX.
Vancouver
1.Mert Nahir, Bünyamin Şahin. Can graphic tablets facilitate expedited and more accurate volume measurements? J. Exp. Clin. Med. [Internet]. 2024 May 1;41(2):233-8. Available from: https://izlik.org/JA59CJ54TX
