BibTex RIS Cite

Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri

Year 1992, Volume: 9 Issue: 2, - , 22.12.2009

Abstract

THE RELIABILITY OF THE TAP TEST AT THE PREDICTION OF FETAL PULMONARY MATURITY
✓ It has been reported that the tap test is reliable and a rapid indicator of fetal pulmonary ma¬turity. In this study, we investigated the reliability of the tap test to determine fetal pulmonary maturity in term and preterm deliveries. We found out that the tap test was a reliabl test with a sensitivity of 75%, specificity of 100 %, positive predictive value of 100% and a negative predicti¬ve value of 82% in preterm deliveries. In term deliveries, the test had sensitivity of 92%, specifi¬city of 100%, positive predictive value of 100% and negative predictive value of 17% . We conc¬luded that the tap test could be routinely used as a rapid indicator of fetal pulmonary maturity.


Tap testinin fetal pulmoner maturité tayininde güvenilir ve hızlı bir test olduğu rapor edil-miştir. Çalışmamızda, matür ve prematür doğumlarda, tap testinin pulmoner maturité tayinindeki güvenirliliğini araştırdık. Prematür doğumlarda nRDS yi saptamada, metodunsensitivitesini % 75, spesifisitesini % 100, pozitif prediktif değerini % 100, negatif prediktif değerini % 82 olarak bulduk. Matür doğumlarda testin sensitivitesi % 92,spesifisitesi % 100, pozitif prediktif değeri % 100, negatif prediktif değeri % 17 idi.Tap testinin fetal pulmoner maturité tayini için rutin olarak kullanılabilecek bir test olduğu sonucuna vardık.

Year 1992, Volume: 9 Issue: 2, - , 22.12.2009

Abstract

There are 0 citations in total.

Details

Primary Language English
Journal Section Basic Medical Sciences
Authors

E. Malatyalıoğlu This is me

A. Kökçü This is me

T. Alper This is me

Ş. Çokşenim This is me

Publication Date December 22, 2009
Submission Date November 23, 2009
Published in Issue Year 1992 Volume: 9 Issue: 2

Cite

APA Malatyalıoğlu, E., Kökçü, A., Alper, T., Çokşenim, Ş. (2009). Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri. Journal of Experimental and Clinical Medicine, 9(2). https://doi.org/10.5835/jecm.v9i2.403
AMA Malatyalıoğlu E, Kökçü A, Alper T, Çokşenim Ş. Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri. J. Exp. Clin. Med. December 2009;9(2). doi:10.5835/jecm.v9i2.403
Chicago Malatyalıoğlu, E., A. Kökçü, T. Alper, and Ş. Çokşenim. “Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri”. Journal of Experimental and Clinical Medicine 9, no. 2 (December 2009). https://doi.org/10.5835/jecm.v9i2.403.
EndNote Malatyalıoğlu E, Kökçü A, Alper T, Çokşenim Ş (December 1, 2009) Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri. Journal of Experimental and Clinical Medicine 9 2
IEEE E. Malatyalıoğlu, A. Kökçü, T. Alper, and Ş. Çokşenim, “Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri”, J. Exp. Clin. Med., vol. 9, no. 2, 2009, doi: 10.5835/jecm.v9i2.403.
ISNAD Malatyalıoğlu, E. et al. “Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri”. Journal of Experimental and Clinical Medicine 9/2 (December 2009). https://doi.org/10.5835/jecm.v9i2.403.
JAMA Malatyalıoğlu E, Kökçü A, Alper T, Çokşenim Ş. Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri. J. Exp. Clin. Med. 2009;9. doi:10.5835/jecm.v9i2.403.
MLA Malatyalıoğlu, E. et al. “Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri”. Journal of Experimental and Clinical Medicine, vol. 9, no. 2, 2009, doi:10.5835/jecm.v9i2.403.
Vancouver Malatyalıoğlu E, Kökçü A, Alper T, Çokşenim Ş. Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri. J. Exp. Clin. Med. 2009;9(2).