BibTex RIS Kaynak Göster

Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri

Yıl 1992, Cilt: 9 Sayı: 2, - , 22.12.2009

Öz

THE RELIABILITY OF THE TAP TEST AT THE PREDICTION OF FETAL PULMONARY MATURITY
✓ It has been reported that the tap test is reliable and a rapid indicator of fetal pulmonary ma¬turity. In this study, we investigated the reliability of the tap test to determine fetal pulmonary maturity in term and preterm deliveries. We found out that the tap test was a reliabl test with a sensitivity of 75%, specificity of 100 %, positive predictive value of 100% and a negative predicti¬ve value of 82% in preterm deliveries. In term deliveries, the test had sensitivity of 92%, specifi¬city of 100%, positive predictive value of 100% and negative predictive value of 17% . We conc¬luded that the tap test could be routinely used as a rapid indicator of fetal pulmonary maturity.


Tap testinin fetal pulmoner maturité tayininde güvenilir ve hızlı bir test olduğu rapor edil-miştir. Çalışmamızda, matür ve prematür doğumlarda, tap testinin pulmoner maturité tayinindeki güvenirliliğini araştırdık. Prematür doğumlarda nRDS yi saptamada, metodunsensitivitesini % 75, spesifisitesini % 100, pozitif prediktif değerini % 100, negatif prediktif değerini % 82 olarak bulduk. Matür doğumlarda testin sensitivitesi % 92,spesifisitesi % 100, pozitif prediktif değeri % 100, negatif prediktif değeri % 17 idi.Tap testinin fetal pulmoner maturité tayini için rutin olarak kullanılabilecek bir test olduğu sonucuna vardık.

Yıl 1992, Cilt: 9 Sayı: 2, - , 22.12.2009

Öz

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Bölüm Basic Medical Sciences
Yazarlar

E. Malatyalıoğlu Bu kişi benim

A. Kökçü Bu kişi benim

T. Alper Bu kişi benim

Ş. Çokşenim Bu kişi benim

Yayımlanma Tarihi 22 Aralık 2009
Gönderilme Tarihi 23 Kasım 2009
Yayımlandığı Sayı Yıl 1992 Cilt: 9 Sayı: 2

Kaynak Göster

APA Malatyalıoğlu, E., Kökçü, A., Alper, T., Çokşenim, Ş. (2009). Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri. Journal of Experimental and Clinical Medicine, 9(2). https://doi.org/10.5835/jecm.v9i2.403
AMA Malatyalıoğlu E, Kökçü A, Alper T, Çokşenim Ş. Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri. J. Exp. Clin. Med. Aralık 2009;9(2). doi:10.5835/jecm.v9i2.403
Chicago Malatyalıoğlu, E., A. Kökçü, T. Alper, ve Ş. Çokşenim. “Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri”. Journal of Experimental and Clinical Medicine 9, sy. 2 (Aralık 2009). https://doi.org/10.5835/jecm.v9i2.403.
EndNote Malatyalıoğlu E, Kökçü A, Alper T, Çokşenim Ş (01 Aralık 2009) Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri. Journal of Experimental and Clinical Medicine 9 2
IEEE E. Malatyalıoğlu, A. Kökçü, T. Alper, ve Ş. Çokşenim, “Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri”, J. Exp. Clin. Med., c. 9, sy. 2, 2009, doi: 10.5835/jecm.v9i2.403.
ISNAD Malatyalıoğlu, E. vd. “Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri”. Journal of Experimental and Clinical Medicine 9/2 (Aralık 2009). https://doi.org/10.5835/jecm.v9i2.403.
JAMA Malatyalıoğlu E, Kökçü A, Alper T, Çokşenim Ş. Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri. J. Exp. Clin. Med. 2009;9. doi:10.5835/jecm.v9i2.403.
MLA Malatyalıoğlu, E. vd. “Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri”. Journal of Experimental and Clinical Medicine, c. 9, sy. 2, 2009, doi:10.5835/jecm.v9i2.403.
Vancouver Malatyalıoğlu E, Kökçü A, Alper T, Çokşenim Ş. Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri. J. Exp. Clin. Med. 2009;9(2).