A New Dynamic Arm Holding Device For Microsurgical Operations In Neurosurgery

Yıl 2011, Cilt: 28 Sayı: 3, 111 - 116, 09.02.2012

Öz

ABSTRACT
The hand holding devices are generally used during the course of micro-surgical operations
in neurosurgery to prevent hand tremor. Recently we designed a new instrument for
holding two arms. This instrument used for stabilization of two arms especially during
microsurgical operations. We used this instrument in different type of operations such
as aneurysm surgery, brain tumor surgery, hypophysis surgery, pontocerebellar tumor
surgery and posterior fossa surgery. The ability of the instrument in the preventing of arm
tremor, and comfort of the arm during surgery was graded as bad, good and excellent in
terms of the description of surgeon during microsurgical operations. This instrument was
used during 20 neurosurgical operations. The capability of the instrument during microsurgical
operation was found as excellent in 65% of the operations. The capability was
found as good in 35% of the operation. In conclusion; this instrument holds two arms
in the same time and provide unrelated moving from each others. The capability of this
instrument is high in the preventing of hand tremor. This instrument may be used during
microsurgical operations in neurosurgery.
J. Exp. Clin. Med., 2011; 28:111-116

Kaynakça

  • Gilsbach, J.M., Lutze, T., Seeger, W., 1984. Combined retractor and hand-rest system for neurosurgery. Neurosurg. Rev. 7, 85-87.
  • Gilsbach, J.M., Mann, W.J., Rochels, R., Amedee, R.G., Lieb, W., Laborde, G.,1994. Pterional/Lateral approach to orbital tumors. Skull Base Surg. 4, 72-5.
  • Kriss, T.C., Kriss V.M., 1998. History of the operating microscope: from magnifying glass to microneurosurgery. Neurosurgery. 42, 899-907.
  • Sugita, K., Kobayashi, S., Takemae, T., Matsuo, K., Yokoo, A., 1980. Direct retraction method in aneurysm surgery. Technical note. J. Neurosurg. 53, 417-419.
  • Sugita, K., Kobayashi, S., Shintani, A., Mutsuga, N., 1979. Microneurosurgery for aneurysms of the basilar artery. J. Neurosurg. 51, 615-20.
  • Sugita, K., Hirota, T., Mizutani, T., Mutsuga, N., Shibuya, M., Tsugane, R., 1978. A newly designed multipurpose microneurosurgical head frame. Technical note. J. Neurosurg. 48, 656-657.
  • Yaşargil, M.G., 2010. Personal considerations on the history of microneurosurgery. J. Neurosurg. 112, 1347.
  • Yaşargil, M.G., 2005. From the microsurgical laboratory to the operating theatre. Acta Neurochir (Wien). 147, 465-468.
  • Yaşargil, M.G., 1999. A legacy of microneurosurgery: memoirs, lessons, and axioms. Neurosurgery. 45, 1025-1092.
  • Yasargil, M.G., 1997. The advent of microsurgery. Mt. Sinai J. Med. May. 64, 164-165.
  • Yaşargil, M.G., 1988. Reflections of a neurosurgeon. Clin. Neurosurg. 34, 16-21.
  • Yaşargil, M.G., Boehm, WB., Ho, RE. 1978. Microsurgical treatment of cerebral aneurysms at the bifurcation of the internal carotid artery. Acta Neurochir (Wien). 41, 61-72.
  • Yaşargil, M.G., Chandler, W.F., Jabre, A.F., Roth, P., 1988. Neurosurgical horizons. Clin. Neurosurg. 34, 22-41.
  • Yasargil, M.G., Vise, W.M., Bader, D.C., 1977. Technical adjuncts in neurosurgery. Surg. Neurol. 8, 331-336
Yıl 2011, Cilt: 28 Sayı: 3, 111 - 116, 09.02.2012

Öz

Kaynakça

  • Gilsbach, J.M., Lutze, T., Seeger, W., 1984. Combined retractor and hand-rest system for neurosurgery. Neurosurg. Rev. 7, 85-87.
  • Gilsbach, J.M., Mann, W.J., Rochels, R., Amedee, R.G., Lieb, W., Laborde, G.,1994. Pterional/Lateral approach to orbital tumors. Skull Base Surg. 4, 72-5.
  • Kriss, T.C., Kriss V.M., 1998. History of the operating microscope: from magnifying glass to microneurosurgery. Neurosurgery. 42, 899-907.
  • Sugita, K., Kobayashi, S., Takemae, T., Matsuo, K., Yokoo, A., 1980. Direct retraction method in aneurysm surgery. Technical note. J. Neurosurg. 53, 417-419.
  • Sugita, K., Kobayashi, S., Shintani, A., Mutsuga, N., 1979. Microneurosurgery for aneurysms of the basilar artery. J. Neurosurg. 51, 615-20.
  • Sugita, K., Hirota, T., Mizutani, T., Mutsuga, N., Shibuya, M., Tsugane, R., 1978. A newly designed multipurpose microneurosurgical head frame. Technical note. J. Neurosurg. 48, 656-657.
  • Yaşargil, M.G., 2010. Personal considerations on the history of microneurosurgery. J. Neurosurg. 112, 1347.
  • Yaşargil, M.G., 2005. From the microsurgical laboratory to the operating theatre. Acta Neurochir (Wien). 147, 465-468.
  • Yaşargil, M.G., 1999. A legacy of microneurosurgery: memoirs, lessons, and axioms. Neurosurgery. 45, 1025-1092.
  • Yasargil, M.G., 1997. The advent of microsurgery. Mt. Sinai J. Med. May. 64, 164-165.
  • Yaşargil, M.G., 1988. Reflections of a neurosurgeon. Clin. Neurosurg. 34, 16-21.
  • Yaşargil, M.G., Boehm, WB., Ho, RE. 1978. Microsurgical treatment of cerebral aneurysms at the bifurcation of the internal carotid artery. Acta Neurochir (Wien). 41, 61-72.
  • Yaşargil, M.G., Chandler, W.F., Jabre, A.F., Roth, P., 1988. Neurosurgical horizons. Clin. Neurosurg. 34, 22-41.
  • Yasargil, M.G., Vise, W.M., Bader, D.C., 1977. Technical adjuncts in neurosurgery. Surg. Neurol. 8, 331-336
Toplam 14 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Bölüm Surgery Medical Sciences
Yazarlar

Adnan Altun

Cengiz Çokluk Bu kişi benim

Keramettin Aydın Bu kişi benim

Murat Sinan Engin Bu kişi benim

Ercan Yarar Bu kişi benim

Yayımlanma Tarihi 9 Şubat 2012
Gönderilme Tarihi 20 Ekim 2011
Yayımlandığı Sayı Yıl 2011 Cilt: 28 Sayı: 3

Kaynak Göster

APA Altun, A., Çokluk, C., Aydın, K., Engin, M. S., vd. (2012). A New Dynamic Arm Holding Device For Microsurgical Operations In Neurosurgery. Journal of Experimental and Clinical Medicine, 28(3), 111-116. https://doi.org/10.5835/jecm.omu.28.03.007
AMA Altun A, Çokluk C, Aydın K, Engin MS, Yarar E. A New Dynamic Arm Holding Device For Microsurgical Operations In Neurosurgery. J. Exp. Clin. Med. Şubat 2012;28(3):111-116. doi:10.5835/jecm.omu.28.03.007
Chicago Altun, Adnan, Cengiz Çokluk, Keramettin Aydın, Murat Sinan Engin, ve Ercan Yarar. “A New Dynamic Arm Holding Device For Microsurgical Operations In Neurosurgery”. Journal of Experimental and Clinical Medicine 28, sy. 3 (Şubat 2012): 111-16. https://doi.org/10.5835/jecm.omu.28.03.007.
EndNote Altun A, Çokluk C, Aydın K, Engin MS, Yarar E (01 Şubat 2012) A New Dynamic Arm Holding Device For Microsurgical Operations In Neurosurgery. Journal of Experimental and Clinical Medicine 28 3 111–116.
IEEE A. Altun, C. Çokluk, K. Aydın, M. S. Engin, ve E. Yarar, “A New Dynamic Arm Holding Device For Microsurgical Operations In Neurosurgery”, J. Exp. Clin. Med., c. 28, sy. 3, ss. 111–116, 2012, doi: 10.5835/jecm.omu.28.03.007.
ISNAD Altun, Adnan vd. “A New Dynamic Arm Holding Device For Microsurgical Operations In Neurosurgery”. Journal of Experimental and Clinical Medicine 28/3 (Şubat 2012), 111-116. https://doi.org/10.5835/jecm.omu.28.03.007.
JAMA Altun A, Çokluk C, Aydın K, Engin MS, Yarar E. A New Dynamic Arm Holding Device For Microsurgical Operations In Neurosurgery. J. Exp. Clin. Med. 2012;28:111–116.
MLA Altun, Adnan vd. “A New Dynamic Arm Holding Device For Microsurgical Operations In Neurosurgery”. Journal of Experimental and Clinical Medicine, c. 28, sy. 3, 2012, ss. 111-6, doi:10.5835/jecm.omu.28.03.007.
Vancouver Altun A, Çokluk C, Aydın K, Engin MS, Yarar E. A New Dynamic Arm Holding Device For Microsurgical Operations In Neurosurgery. J. Exp. Clin. Med. 2012;28(3):111-6.