BibTex RIS Kaynak Göster

Evaluation of tympanic cavity volume by using computed tomography scan with the MATLAB and image J

Yıl 2014, Cilt: 31 Sayı: 2, 0 - , 10.09.2014

Öz

The aim of this study is to calculate the tympanic cavity (TC) volume with manual tracing technique on computed tomography images of temporal bone with a software developed in house using MATLAB platform. Images with slice thickness of 0.25 mm were obtained from newborn cadavers and analyzed by two expert researchers independently using the software and the results were compared. The borders of TC were delineated manually and measurement of interested area was calculated on masked images. Then, the area measurements from all sections were added for the calculation of total volume. Dice similarity coefficient (DSC), Jaccard, sensitivity and specificity were used as a statistical validation metric to evaluate the performance of manual volume measurement. TC volumes were calculated as a 0.272±0.04 cmand 0.286±0.03 cm3 by the two researchers with MATLAB, 0.287±0.06 cm3 with Image J. DSC values being above to 0.7 indicated that the software allows consistent and reliable volume measurements. This software can potentially be applied to measure other anatomical volumes from radiological images.

Yıl 2014, Cilt: 31 Sayı: 2, 0 - , 10.09.2014

Öz

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Bölüm Basic Medical Sciences
Yazarlar

Niyazi Acer

Erdoğan Unur Bu kişi benim

M. Fatih Sönmez Bu kişi benim

Gökmen Zararsız Bu kişi benim

Ayla Arslan Bu kişi benim

Mehmet Bilgen Bu kişi benim

Tolga Ertekin Bu kişi benim

Abdulhakim Coşkun Bu kişi benim

Yayımlanma Tarihi 10 Eylül 2014
Gönderilme Tarihi 10 Eylül 2014
Yayımlandığı Sayı Yıl 2014 Cilt: 31 Sayı: 2

Kaynak Göster

APA Acer, N., Unur, E., Sönmez, M. F., Zararsız, G., vd. (2014). Evaluation of tympanic cavity volume by using computed tomography scan with the MATLAB and image J. Journal of Experimental and Clinical Medicine, 31(2). https://doi.org/10.5835/jecm.v2i31.5000068731
AMA Acer N, Unur E, Sönmez MF, Zararsız G, Arslan A, Bilgen M, Ertekin T, Coşkun A. Evaluation of tympanic cavity volume by using computed tomography scan with the MATLAB and image J. J. Exp. Clin. Med. Eylül 2014;31(2). doi:10.5835/jecm.v2i31.5000068731
Chicago Acer, Niyazi, Erdoğan Unur, M. Fatih Sönmez, Gökmen Zararsız, Ayla Arslan, Mehmet Bilgen, Tolga Ertekin, ve Abdulhakim Coşkun. “Evaluation of Tympanic Cavity Volume by Using Computed Tomography Scan With the MATLAB and Image J”. Journal of Experimental and Clinical Medicine 31, sy. 2 (Eylül 2014). https://doi.org/10.5835/jecm.v2i31.5000068731.
EndNote Acer N, Unur E, Sönmez MF, Zararsız G, Arslan A, Bilgen M, Ertekin T, Coşkun A (01 Eylül 2014) Evaluation of tympanic cavity volume by using computed tomography scan with the MATLAB and image J. Journal of Experimental and Clinical Medicine 31 2
IEEE N. Acer, “Evaluation of tympanic cavity volume by using computed tomography scan with the MATLAB and image J”, J. Exp. Clin. Med., c. 31, sy. 2, 2014, doi: 10.5835/jecm.v2i31.5000068731.
ISNAD Acer, Niyazi vd. “Evaluation of Tympanic Cavity Volume by Using Computed Tomography Scan With the MATLAB and Image J”. Journal of Experimental and Clinical Medicine 31/2 (Eylül 2014). https://doi.org/10.5835/jecm.v2i31.5000068731.
JAMA Acer N, Unur E, Sönmez MF, Zararsız G, Arslan A, Bilgen M, Ertekin T, Coşkun A. Evaluation of tympanic cavity volume by using computed tomography scan with the MATLAB and image J. J. Exp. Clin. Med. 2014;31. doi:10.5835/jecm.v2i31.5000068731.
MLA Acer, Niyazi vd. “Evaluation of Tympanic Cavity Volume by Using Computed Tomography Scan With the MATLAB and Image J”. Journal of Experimental and Clinical Medicine, c. 31, sy. 2, 2014, doi:10.5835/jecm.v2i31.5000068731.
Vancouver Acer N, Unur E, Sönmez MF, Zararsız G, Arslan A, Bilgen M, Ertekin T, Coşkun A. Evaluation of tympanic cavity volume by using computed tomography scan with the MATLAB and image J. J. Exp. Clin. Med. 2014;31(2).