BibTex RIS Kaynak Göster

Are we sure to count myelinated fibers entirely? Calibration of a stereological study

Yıl 2014, Cilt: 31 Sayı: 2, 0 - , 10.09.2014

Öz

Peripheral nerves are subject to many different types of injuries frequently and these injuries may result in partial or total loss of motor and sensory functions. In contrast to the central nervous system, peripheral nervous system are able to undergo spontaneous regeneration. But clinical and experimental studies show that this regeneration is mostly not satisfactory. One of the most important neuropathological indicators of nerve regeneration is quantitative estimation of myelinated axons. Quantitative estimation of the total number of myelinated fibers can be obtained both by light microscopy (LM) and electron microscopy (EM) and depends on using appropriate sampling strategy. In this study, we made a direct comparison between LM and EM estimation of myelinated nerve fibers. Ten female Wistar albino rats were divided into two experimental groups; control group (n=5) and gap group (n=5). In the gap group, 5 mm right sciatic nerve segment of rats were resected to form a gap. Proximal and distal nerve stumps were surrounded by collagen membrane following resection. In the control group, rats received neither any operation nor any treatment. Rats were sacrificed at 12 week after surgery. Nerve samples were embedded in resin. Semi and ultra thin sections (of 1 μm and 100 nm thickness, respectively) were cut and stained with 1% toluidine blue (for LM) and uranyl acetate-lead citrate (for EM). Histological assessment of myelinated fibers was performed with both LM and EM using unbiased stereological counting techniques. There was a significant difference in the total number of myelinated nerve fibers between LM and EM examinations in terms of the both pure and regenerating axons. This difference is probably related to different magnification capacities in LM and EM. LM causes to underestimates as a result of possessing very small myelinated fibers, which are only detectable with EM. According to our results it may be concluded that the combination of both light and electron microscopical results is essential especially in revealing regenerating nerve fibers since very small myelinated fibers can not be distinguishable with LM.

Yıl 2014, Cilt: 31 Sayı: 2, 0 - , 10.09.2014

Öz

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Bölüm Basic Medical Sciences
Yazarlar

Mehmet Emin Önger

Stefano Geuna Bu kişi benim

Ebru Elibol Bu kişi benim

Aysın Pınar Turkmen Bu kişi benim

Ömür Gülsüm Deniz Bu kişi benim

Gamze Altun

Süleyman Kaplan Bu kişi benim

Yayımlanma Tarihi 10 Eylül 2014
Gönderilme Tarihi 10 Eylül 2014
Yayımlandığı Sayı Yıl 2014 Cilt: 31 Sayı: 2

Kaynak Göster

APA Önger, M. E., Geuna, S., Elibol, E., Turkmen, A. P., vd. (2014). Are we sure to count myelinated fibers entirely? Calibration of a stereological study. Journal of Experimental and Clinical Medicine, 31(2). https://doi.org/10.5835/jecm.v2i31.5000068749
AMA Önger ME, Geuna S, Elibol E, Turkmen AP, Deniz ÖG, Altun G, Kaplan S. Are we sure to count myelinated fibers entirely? Calibration of a stereological study. J. Exp. Clin. Med. Eylül 2014;31(2). doi:10.5835/jecm.v2i31.5000068749
Chicago Önger, Mehmet Emin, Stefano Geuna, Ebru Elibol, Aysın Pınar Turkmen, Ömür Gülsüm Deniz, Gamze Altun, ve Süleyman Kaplan. “Are We Sure to Count Myelinated Fibers Entirely? Calibration of a Stereological Study”. Journal of Experimental and Clinical Medicine 31, sy. 2 (Eylül 2014). https://doi.org/10.5835/jecm.v2i31.5000068749.
EndNote Önger ME, Geuna S, Elibol E, Turkmen AP, Deniz ÖG, Altun G, Kaplan S (01 Eylül 2014) Are we sure to count myelinated fibers entirely? Calibration of a stereological study. Journal of Experimental and Clinical Medicine 31 2
IEEE M. E. Önger, “Are we sure to count myelinated fibers entirely? Calibration of a stereological study”, J. Exp. Clin. Med., c. 31, sy. 2, 2014, doi: 10.5835/jecm.v2i31.5000068749.
ISNAD Önger, Mehmet Emin vd. “Are We Sure to Count Myelinated Fibers Entirely? Calibration of a Stereological Study”. Journal of Experimental and Clinical Medicine 31/2 (Eylül 2014). https://doi.org/10.5835/jecm.v2i31.5000068749.
JAMA Önger ME, Geuna S, Elibol E, Turkmen AP, Deniz ÖG, Altun G, Kaplan S. Are we sure to count myelinated fibers entirely? Calibration of a stereological study. J. Exp. Clin. Med. 2014;31. doi:10.5835/jecm.v2i31.5000068749.
MLA Önger, Mehmet Emin vd. “Are We Sure to Count Myelinated Fibers Entirely? Calibration of a Stereological Study”. Journal of Experimental and Clinical Medicine, c. 31, sy. 2, 2014, doi:10.5835/jecm.v2i31.5000068749.
Vancouver Önger ME, Geuna S, Elibol E, Turkmen AP, Deniz ÖG, Altun G, Kaplan S. Are we sure to count myelinated fibers entirely? Calibration of a stereological study. J. Exp. Clin. Med. 2014;31(2).