Review
BibTex RIS Cite
Year 2021, Volume: 38 Issue: 3s, 92 - 97, 09.05.2021

Abstract

References

  • Abduo, J. 2013. Occlusal Schemes for Complete Dentures: A Systematic Review. Int J Prosthodont. 26 (1): 26-33.
  • Al-Helal A, Al-Rumaih HS, Kattadiyil MT, Baba NZ, Goodacre CJ. 2016. Comparison of retention between maxillary milled and conventional denture bases: a clinical study. J Prosthet Dent. 117(2):233-8
  • Al-Rumaih HS. 2016. The Effect of Denture Adhesive on the Retention of Digital and Conventional Denture Bases: A Clinical Study [thesis]. Loma Linda, CA: Loma Linda University
  • Alghazzawi TF. 2016. Advancements in CAD/CAM technology: Options for practical implementation. J Prosthodont Res. 60(2):72-84.
  • Baba NZ. 2016. Materials and processes for CAD/CAM complete denture fabrication. Curr Oral Health Rep. 3(3):203-208.
  • Bidra AS, Farrell K, Burnham D, Dhingra A, Taylor TD, Kuo C. 2016. Prospective cohort pilot study of 2-visit CAD/CAM monolithic complete dentures and implant-retained overdentures: clinical and patient-centered outcomes. J Prosthet Dent. 115:578-86.
  • Bidra AS, Taylor TD, Agar JR. 2013. Computer-aided technology for fabricating complete dentures: systematic review of historical background, current status, and future perspectives. J Prosthet Dent. 109(6):361-6.
  • Bilgin MS, Erdem A, Aglarci OS, Dilber E. 2015. Fabricating complete dentures with CAD/CAM and RP technologies. J Prosthodont. 24:576-9.
  • Busch M, Kordass B. 2006. Concept and development of a computerized positioning of prosthetic teeth for complete dentures. Int J Comput Dent. 9:113-20.
  • Dankwort CW, Weidlich R, Guenther B, Blaurock JE. 2004. Engineers’ CAx education-it’s not only CAD. Computer-Aided Design. 36:1439-50.
  • Fernandez MA, Nimmo A, Behar-Horenstein LS. 2016. Digital denture fabrication in pre- and postdoctoral education: a survey of U.S. dental schools. J Prosthodont. 25:83-90.
  • Goodacre BJ, Goodacre CJ, Baba NZ, Kattadiyil MT. 2016. Comparison of complete denture base adaptation between CAD/CAM and conventional fabrication techniques. J Prosthet Dent 116:249-56.
  • Goodacre BJ, Goodacre CJ, Baba NZ, Kattadiyil MT. 2018. Comparison of denture tooth movement betweenCAD-CAm and conventional fabrication techniques. J Prosthet Dent 119(1)108-115
  • Goodacre CJ, Garbacea A, Naylor WP, Daher T, Marchack CB, Lowry J. 2012. CAD/CAM fabricated complete dentures: concepts and clinical methods of obtaining required morphological data. J Prosthet Dent. 107:34-46.
  • Infante L, Yilmaz B, McGlumphy E, Finger I. 2014. Fabricating complete dentures with CAD/CAM technology. J Prosthet Dent. 111(5):351-5.
  • Inokoshi M, Kanazawa M, Minakuchi S. 2012. Evaluation of a complete denture trial method applying rapid prototyping. Dent Mater J. 31:40-6.
  • Kanazawa M, Inokoshi M, Minakuchi S, Ohbayashi N. 2011. Trial of a CAD/CAM system for fabricating complete dentures. Dent Mater J. 30:93-6.
  • Kattadiyil MT, Goodacre CJ, Baba NZ. 2013. CAD/CAM complete dentures: a review of two commercial fabrication systems. J Calif Dent Assoc. 41: 407-16.
  • Kattadiyil MT., Jekki R., Goodacre CJ, Baba NZ. 2015. Comparison of treatment outcomes in digital and conventional complete removable dental prosthesis fabrications in a predoctoral setting. J Prosthet Dent. 114:818-25.
  • Kawahata N, Ono H, Nishi Y, Hamano T, Nagaoka E. 1997. Trial of duplication procedure for complete dentures by CAD/CAM. J Oral Rehabil. 24:540-8.
  • Maeda Y, Minoura M, Tsutsumi S, Okada M, Nokubi T. 1994. A CAD/CAM system for removable denture. Part I: Fabrication of complete dentures. Int J Prosthodont. 7:17-21.
  • Muller F. 2014. Interventions for edentate elders-what is the evidence? Gerodontology. 31 Suppl 1:44-51.
  • Saponaro PC, Yilmaz B, Heshmati RH, McGlumphy EA. 2016. Clinical performance of CAD/CAM-fabricated complete dentures: a cross-sectional study. J Prosthet Dent. 116:431-5.
  • Schwindling FS, Stober T. 2016. A comparison of two digital techniques for the fabrication of complete removable dental prostheses: a pilot clinical study. J Prosthet Dent.116:756-63.
  • Srinivasan M, CAntin Y, Mehl A, Gjendegal H, Müller F, Schimmel M. 2017. CAD/CAm milled removable complete denture: an in vitro evaluation of trueness. Clin Oral Investig. 21(6):2007-19
  • Steinmassl PA, Wiedemair V, Huck C, Klaunzer F, Steinmassl O, Grunert I, Dumfahrt H. 2017. Do CAD/CAM dentures really release less monomer than conventional dentures? Clin Oral Investig. 21:1697-705.
  • Sun Y, Lü P, Wang Y. 2009. Study on CAD&RP for removable complete denture. Comput Methods Programs Biomed. 93:266-72.
  • Viola, AP., Takamiya AS, Monteiro DB, Barbosa DB., 2013. Oral health quality of life and satisfaction before and after treatment with complete dentures in a dental school in Brazil. J Prosthodont Res. 57: 36-41.
  • Wimmer T, Gallus K, Eichberger M, Stawarczyk B. 2016. Complete denture fabrication supported by CAD/CAM. J Prosthet Dent. 115:541-6.
  • www.cadazz.com, 2020. CAD software history [Online]. Available at: https:/www.cadazz.com/cad-software-history.htm (Accessed: 21 April 2020).
  • Zhang YD, Jiang JG, Liang T, Hu WP. 2011. Kinematics modeling and experimentation of the multi-manipulator tooth-arrangement robot for full denture manufacturing. J Med Syst. 35:1421-9.

Clinical outcomes and Complications of CAD-CAM Fabricated Complete Dentures; An update and review

Year 2021, Volume: 38 Issue: 3s, 92 - 97, 09.05.2021

Abstract

For decades, conventional complete dentures (CD) have been a promising treatment for edentulous patients. The introduction of digital technology in CD fabrication streamlines and simplifies the treatment process and offers new and specific applications for the completely edentulous patients. Computer-aided design/computer-assisted manufactured (CAD/CAM) CD protocols can improve efficiency and offer specific applications in specific situations to improve patient care, satisfaction, and convenience. The aim of this review is to assess and evaluate the clinical outcomes and complication of CAD/CAM fabricated CD systems and to provide information about currently available systems for dental practitioners.

References

  • Abduo, J. 2013. Occlusal Schemes for Complete Dentures: A Systematic Review. Int J Prosthodont. 26 (1): 26-33.
  • Al-Helal A, Al-Rumaih HS, Kattadiyil MT, Baba NZ, Goodacre CJ. 2016. Comparison of retention between maxillary milled and conventional denture bases: a clinical study. J Prosthet Dent. 117(2):233-8
  • Al-Rumaih HS. 2016. The Effect of Denture Adhesive on the Retention of Digital and Conventional Denture Bases: A Clinical Study [thesis]. Loma Linda, CA: Loma Linda University
  • Alghazzawi TF. 2016. Advancements in CAD/CAM technology: Options for practical implementation. J Prosthodont Res. 60(2):72-84.
  • Baba NZ. 2016. Materials and processes for CAD/CAM complete denture fabrication. Curr Oral Health Rep. 3(3):203-208.
  • Bidra AS, Farrell K, Burnham D, Dhingra A, Taylor TD, Kuo C. 2016. Prospective cohort pilot study of 2-visit CAD/CAM monolithic complete dentures and implant-retained overdentures: clinical and patient-centered outcomes. J Prosthet Dent. 115:578-86.
  • Bidra AS, Taylor TD, Agar JR. 2013. Computer-aided technology for fabricating complete dentures: systematic review of historical background, current status, and future perspectives. J Prosthet Dent. 109(6):361-6.
  • Bilgin MS, Erdem A, Aglarci OS, Dilber E. 2015. Fabricating complete dentures with CAD/CAM and RP technologies. J Prosthodont. 24:576-9.
  • Busch M, Kordass B. 2006. Concept and development of a computerized positioning of prosthetic teeth for complete dentures. Int J Comput Dent. 9:113-20.
  • Dankwort CW, Weidlich R, Guenther B, Blaurock JE. 2004. Engineers’ CAx education-it’s not only CAD. Computer-Aided Design. 36:1439-50.
  • Fernandez MA, Nimmo A, Behar-Horenstein LS. 2016. Digital denture fabrication in pre- and postdoctoral education: a survey of U.S. dental schools. J Prosthodont. 25:83-90.
  • Goodacre BJ, Goodacre CJ, Baba NZ, Kattadiyil MT. 2016. Comparison of complete denture base adaptation between CAD/CAM and conventional fabrication techniques. J Prosthet Dent 116:249-56.
  • Goodacre BJ, Goodacre CJ, Baba NZ, Kattadiyil MT. 2018. Comparison of denture tooth movement betweenCAD-CAm and conventional fabrication techniques. J Prosthet Dent 119(1)108-115
  • Goodacre CJ, Garbacea A, Naylor WP, Daher T, Marchack CB, Lowry J. 2012. CAD/CAM fabricated complete dentures: concepts and clinical methods of obtaining required morphological data. J Prosthet Dent. 107:34-46.
  • Infante L, Yilmaz B, McGlumphy E, Finger I. 2014. Fabricating complete dentures with CAD/CAM technology. J Prosthet Dent. 111(5):351-5.
  • Inokoshi M, Kanazawa M, Minakuchi S. 2012. Evaluation of a complete denture trial method applying rapid prototyping. Dent Mater J. 31:40-6.
  • Kanazawa M, Inokoshi M, Minakuchi S, Ohbayashi N. 2011. Trial of a CAD/CAM system for fabricating complete dentures. Dent Mater J. 30:93-6.
  • Kattadiyil MT, Goodacre CJ, Baba NZ. 2013. CAD/CAM complete dentures: a review of two commercial fabrication systems. J Calif Dent Assoc. 41: 407-16.
  • Kattadiyil MT., Jekki R., Goodacre CJ, Baba NZ. 2015. Comparison of treatment outcomes in digital and conventional complete removable dental prosthesis fabrications in a predoctoral setting. J Prosthet Dent. 114:818-25.
  • Kawahata N, Ono H, Nishi Y, Hamano T, Nagaoka E. 1997. Trial of duplication procedure for complete dentures by CAD/CAM. J Oral Rehabil. 24:540-8.
  • Maeda Y, Minoura M, Tsutsumi S, Okada M, Nokubi T. 1994. A CAD/CAM system for removable denture. Part I: Fabrication of complete dentures. Int J Prosthodont. 7:17-21.
  • Muller F. 2014. Interventions for edentate elders-what is the evidence? Gerodontology. 31 Suppl 1:44-51.
  • Saponaro PC, Yilmaz B, Heshmati RH, McGlumphy EA. 2016. Clinical performance of CAD/CAM-fabricated complete dentures: a cross-sectional study. J Prosthet Dent. 116:431-5.
  • Schwindling FS, Stober T. 2016. A comparison of two digital techniques for the fabrication of complete removable dental prostheses: a pilot clinical study. J Prosthet Dent.116:756-63.
  • Srinivasan M, CAntin Y, Mehl A, Gjendegal H, Müller F, Schimmel M. 2017. CAD/CAm milled removable complete denture: an in vitro evaluation of trueness. Clin Oral Investig. 21(6):2007-19
  • Steinmassl PA, Wiedemair V, Huck C, Klaunzer F, Steinmassl O, Grunert I, Dumfahrt H. 2017. Do CAD/CAM dentures really release less monomer than conventional dentures? Clin Oral Investig. 21:1697-705.
  • Sun Y, Lü P, Wang Y. 2009. Study on CAD&RP for removable complete denture. Comput Methods Programs Biomed. 93:266-72.
  • Viola, AP., Takamiya AS, Monteiro DB, Barbosa DB., 2013. Oral health quality of life and satisfaction before and after treatment with complete dentures in a dental school in Brazil. J Prosthodont Res. 57: 36-41.
  • Wimmer T, Gallus K, Eichberger M, Stawarczyk B. 2016. Complete denture fabrication supported by CAD/CAM. J Prosthet Dent. 115:541-6.
  • www.cadazz.com, 2020. CAD software history [Online]. Available at: https:/www.cadazz.com/cad-software-history.htm (Accessed: 21 April 2020).
  • Zhang YD, Jiang JG, Liang T, Hu WP. 2011. Kinematics modeling and experimentation of the multi-manipulator tooth-arrangement robot for full denture manufacturing. J Med Syst. 35:1421-9.
There are 31 citations in total.

Details

Primary Language English
Subjects Health Care Administration
Journal Section Clinical Research
Authors

Emir Yüzbaşıoğlu 0000-0001-5348-6954

Yeşim Ölçer Us

Gökhan Özdemir

Berkman Albayrak

Publication Date May 9, 2021
Submission Date May 26, 2020
Acceptance Date December 14, 2020
Published in Issue Year 2021 Volume: 38 Issue: 3s

Cite

APA Yüzbaşıoğlu, E., Ölçer Us, Y., Özdemir, G., Albayrak, B. (2021). Clinical outcomes and Complications of CAD-CAM Fabricated Complete Dentures; An update and review. Journal of Experimental and Clinical Medicine, 38(3s), 92-97.
AMA Yüzbaşıoğlu E, Ölçer Us Y, Özdemir G, Albayrak B. Clinical outcomes and Complications of CAD-CAM Fabricated Complete Dentures; An update and review. J. Exp. Clin. Med. May 2021;38(3s):92-97.
Chicago Yüzbaşıoğlu, Emir, Yeşim Ölçer Us, Gökhan Özdemir, and Berkman Albayrak. “Clinical Outcomes and Complications of CAD-CAM Fabricated Complete Dentures; An Update and Review”. Journal of Experimental and Clinical Medicine 38, no. 3s (May 2021): 92-97.
EndNote Yüzbaşıoğlu E, Ölçer Us Y, Özdemir G, Albayrak B (May 1, 2021) Clinical outcomes and Complications of CAD-CAM Fabricated Complete Dentures; An update and review. Journal of Experimental and Clinical Medicine 38 3s 92–97.
IEEE E. Yüzbaşıoğlu, Y. Ölçer Us, G. Özdemir, and B. Albayrak, “Clinical outcomes and Complications of CAD-CAM Fabricated Complete Dentures; An update and review”, J. Exp. Clin. Med., vol. 38, no. 3s, pp. 92–97, 2021.
ISNAD Yüzbaşıoğlu, Emir et al. “Clinical Outcomes and Complications of CAD-CAM Fabricated Complete Dentures; An Update and Review”. Journal of Experimental and Clinical Medicine 38/3s (May 2021), 92-97.
JAMA Yüzbaşıoğlu E, Ölçer Us Y, Özdemir G, Albayrak B. Clinical outcomes and Complications of CAD-CAM Fabricated Complete Dentures; An update and review. J. Exp. Clin. Med. 2021;38:92–97.
MLA Yüzbaşıoğlu, Emir et al. “Clinical Outcomes and Complications of CAD-CAM Fabricated Complete Dentures; An Update and Review”. Journal of Experimental and Clinical Medicine, vol. 38, no. 3s, 2021, pp. 92-97.
Vancouver Yüzbaşıoğlu E, Ölçer Us Y, Özdemir G, Albayrak B. Clinical outcomes and Complications of CAD-CAM Fabricated Complete Dentures; An update and review. J. Exp. Clin. Med. 2021;38(3s):92-7.