<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.4 20241031//EN"
        "https://jats.nlm.nih.gov/publishing/1.4/JATS-journalpublishing1-4.dtd">
<article  article-type="research-article"        dtd-version="1.4">
            <front>

                <journal-meta>
                                    <journal-id></journal-id>
            <journal-title-group>
                                                                                    <journal-title>Politeknik Dergisi</journal-title>
            </journal-title-group>
                                        <issn pub-type="epub">2147-9429</issn>
                                                                                            <publisher>
                    <publisher-name>Gazi Üniversitesi</publisher-name>
                </publisher>
                    </journal-meta>
                <article-meta>
                                        <article-id pub-id-type="doi">10.2339/politeknik.1038817</article-id>
                                                                <article-categories>
                                            <subj-group  xml:lang="en">
                                                            <subject>Engineering</subject>
                                                    </subj-group>
                                            <subj-group  xml:lang="tr">
                                                            <subject>Mühendislik</subject>
                                                    </subj-group>
                                    </article-categories>
                                                                                                                                                        <title-group>
                                                                                                                        <article-title>Doğalgaz Yakıtlı Bir Kombine Çevrim Santralinin Enerji ve Ekserji Analizi: Parametrik Çalışma</article-title>
                                                                                                                                                                                                <trans-title-group xml:lang="en">
                                    <trans-title>Energy and Exergy Analyses of a Natural Gas Fired Combined Cycle Power Plant: Parametric Study</trans-title>
                                </trans-title-group>
                                                                                                    </title-group>
            
                                                    <contrib-group content-type="authors">
                                                                        <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0000-0002-8472-9426</contrib-id>
                                                                <name>
                                    <surname>Kılıç</surname>
                                    <given-names>Ahmed Emin</given-names>
                                </name>
                                                                    <aff>ANKARA YILDIRIM BEYAZIT UNIVERSITY</aff>
                                                            </contrib>
                                                    <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0000-0001-8073-5207</contrib-id>
                                                                <name>
                                    <surname>Arcaklıoğlu</surname>
                                    <given-names>Erol</given-names>
                                </name>
                                                                    <aff>YILDIRIM BEYAZIT ÜNİVERSİTESİ</aff>
                                                            </contrib>
                                                                                </contrib-group>
                        
                                        <pub-date pub-type="pub" iso-8601-date="20230705">
                    <day>07</day>
                    <month>05</month>
                    <year>2023</year>
                </pub-date>
                                        <volume>26</volume>
                                        <issue>2</issue>
                                        <fpage>721</fpage>
                                        <lpage>730</lpage>
                        
                        <history>
                                    <date date-type="received" iso-8601-date="20211220">
                        <day>12</day>
                        <month>20</month>
                        <year>2021</year>
                    </date>
                                                    <date date-type="accepted" iso-8601-date="20220110">
                        <day>01</day>
                        <month>10</month>
                        <year>2022</year>
                    </date>
                            </history>
                                        <permissions>
                    <copyright-statement>Copyright © 1998, Politeknik Dergisi</copyright-statement>
                    <copyright-year>1998</copyright-year>
                    <copyright-holder>Politeknik Dergisi</copyright-holder>
                </permissions>
            
                                                                                                <abstract><p>Nükleer, biyoyakıtlar ve yenilenebilir enerji kaynaklarının enerji üretimindeki kullanımları gün geçtikçe artsa da enerji üretiminde fosil yakıt kullanımı yaygın olarak devam etmektedir. Fosil yakıtların daha verimli bir şekilde kullanılmasını sağlayan en iyi seçeneklerin başında kombine çevrim santralleri gelmektedir. Brayton ve Rankine çevrimlerinin birleştirilmesinden oluşan bu santraller bir taraftan fosil yakıtları daha verimli kullanırken, diğer yandan çevreye daha az zarar vermektedir. Bu çalışmada doğalgazla çalışan bir kombine çevrim santralinin enerji ve ekserji analizleri, santralin gerçek operasyon verileri kullanılarak gerçekleştirilmiştir. Ortam sıcaklığının ve basıncının sırasıyla 25,4 °C ve 98,1 kPa olduğu şartlarda gerçekleştirilen analizler sonucunda, santralin ekserji verimi % 61,2 olarak bulunurken, en yüksek ekserji kaybına sahip olan bileşen 89 MW ile yanma odası olmuştur. Ekserji verimi en yüksek santral bileşeni ise % 96,4 ile yoğuşturucu olarak tespit edilmiştir. Santralden elde edilen toplam güç 205 MW olarak hesaplanırken Brayton çevriminin gücü 134 MW, Rankine çevriminin gücü 71 MW olarak hesaplanmıştır. Ortam sıcaklığı ile gaz türbini giriş sıcaklığının arttırılmasının etkileri bu çalışmada ayrıca incelenmiştir.</p></abstract>
                                                                                                                                    <trans-abstract xml:lang="en">
                            <p>Despite the increasing use of nuclear, biofuels, and renewable energy sources in energy production, the use of fossil fuels in energy production continues widely. Combined cycle power plants are among the best options that enable the more efficient use of fossil fuels. These power plants, which use a combination of the Brayton and Rankine cycles, use fossil fuels more efficiently while also cause less environmental damage. In this study, energy and exergy analysis of a natural gas-fired combined cycle power plant was carried out using the actual operational data of the power plant. The exergy efficiency of the power plant was determined to be 61.2 % as a result of the analyses performed under conditions where the ambient temperature and pressure were 25.4 °C and 98.1 kPa, respectively, while the component with the highest exergy destruction was the combustion chamber with 89 MW. The condenser was determined to be the most exergy efficient component of the power plant, with a 96.4 % efficiency rating. While the total power obtained from the power plant is 205 MW, the power of the Brayton cycle is 134 MW and the power of the Rankine cycle is 71 MW. In this study, the effects of increasing the ambient temperature and the gas turbine inlet temperature were also investigated.</p></trans-abstract>
                                                            
            
                                                            <kwd-group>
                                                    <kwd>Enerji</kwd>
                                                    <kwd>  ekserji</kwd>
                                                    <kwd>  kombine çevrim santrali</kwd>
                                                    <kwd>  Brayton çevrimi</kwd>
                                                    <kwd>  Rankine çevrimi</kwd>
                                            </kwd-group>
                                                        
                                                                            <kwd-group xml:lang="en">
                                                    <kwd>Energy</kwd>
                                                    <kwd>  exergy</kwd>
                                                    <kwd>  combined cycle power plant</kwd>
                                                    <kwd>  Brayton cycle</kwd>
                                                    <kwd>  Rankine cycle</kwd>
                                            </kwd-group>
                                                                                                            </article-meta>
    </front>
    <back>
                            <ref-list>
                                    <ref id="ref1">
                        <label>1</label>
                        <mixed-citation publication-type="journal">[1]	Ali M. S., Shafique Q. N., Kumar D., Kumar S., and Kumar S., “Energy and exergy analysis of a 747-MW combined cycle power plant Guddu”. International Journal of Ambient Energy, 41(13): 1495-1504, (2020).</mixed-citation>
                    </ref>
                                    <ref id="ref2">
                        <label>2</label>
                        <mixed-citation publication-type="journal">[2]	Ibrahim T. K., Mohammed M. K., Awad O. I., Abdalla A. N., Basrawi F., Mohammed M. N., and Mamat R., “A comprehensive review on the exergy analysis of combined cycle power plants”. Renewable and Sustainable Energy Reviews, 90: 835-850, (2018).</mixed-citation>
                    </ref>
                                    <ref id="ref3">
                        <label>3</label>
                        <mixed-citation publication-type="journal">[3]	Aliyu M., AlQudaihi A. B., Said S. A., and Habib M. A., “Energy, exergy and parametric analysis of a combined cycle power plant”. Thermal Science and Engineering Progress, 15: 100450, (2020).</mixed-citation>
                    </ref>
                                    <ref id="ref4">
                        <label>4</label>
                        <mixed-citation publication-type="journal">[4]	Kotowicz J., and Brzęczek M., “Analysis of increasing efficiency of modern combined cycle power plant: A case study”. Energy, 153: 90-99, (2018).</mixed-citation>
                    </ref>
                                    <ref id="ref5">
                        <label>5</label>
                        <mixed-citation publication-type="journal">[5]	Koç Y., and Yağlı H., “Isı-güç kombine sistemlerinde kullanılan kalina çevriminin enerji ve ekserji analizi”. Politeknik Dergisi, 23(1): 181-188, (2020).</mixed-citation>
                    </ref>
                                    <ref id="ref6">
                        <label>6</label>
                        <mixed-citation publication-type="journal">[6]	Karaağaç M. O., Kabul A., and Oğul H., “First-and second-law thermodynamic analyses of a combined natural gas cycle power plant: Sankey and Grossman diagrams”. Turkish Journal of Physics, 
43(1): 93-108, (2019).</mixed-citation>
                    </ref>
                                    <ref id="ref7">
                        <label>7</label>
                        <mixed-citation publication-type="journal">[7]	Dincer I., and Rosen M. A., “Exergy: energy, environment and sustainable development”. İkinci Baskı, Elsevier, İngiltere (2013).</mixed-citation>
                    </ref>
                                    <ref id="ref8">
                        <label>8</label>
                        <mixed-citation publication-type="journal">[8]	Mohtaram S., Sun H., Lin J., Chen W., and Sun Y., “Multi-Objective Evolutionary Optimization &amp; 4E analysis of a bulky combined cycle power plant by CO2/CO/NOx reduction and cost controlling 
targets”. Renewable and Sustainable Energy Reviews, 128: 109898, (2020).</mixed-citation>
                    </ref>
                                    <ref id="ref9">
                        <label>9</label>
                        <mixed-citation publication-type="journal">[9]	Prakash D., and Singh O., &quot;Thermo-economic study of combined cycle power plant with carbon capture and methanation”. Journal of Cleaner Production, 231: 529-542, (2019).</mixed-citation>
                    </ref>
                                    <ref id="ref10">
                        <label>10</label>
                        <mixed-citation publication-type="journal">[10]	Khan M. N., and Tlili I., “New advancement of high performance for a combined cycle power plant: thermodynamic analysis”. Case Studies in Thermal Engineering, 12: 166-175, (2018).</mixed-citation>
                    </ref>
                                    <ref id="ref11">
                        <label>11</label>
                        <mixed-citation publication-type="journal">[11]	Şen G., Nil M., Mamur H., Doğan H., Karamolla M., Karaçor M., and Bhuiyan M. R. A., “The effect of ambient temperature on electric power generation in natural gas combined cycle power plant-A 
case study”. Energy Reports, 4: 682-690, (2018).</mixed-citation>
                    </ref>
                                    <ref id="ref12">
                        <label>12</label>
                        <mixed-citation publication-type="journal">[12]	Abuelnuor A. A. A., Saqr K. M., Mohieldein S. A. A., Dafallah K. A., Abdullah M. M., and Nogoud Y. A. M. &quot;Exergy analysis of Garri “2” 180 MW combined cycle power plant”. Renewable and Sustainable 
Energy Reviews, 79: 960-969, (2017).</mixed-citation>
                    </ref>
                                    <ref id="ref13">
                        <label>13</label>
                        <mixed-citation publication-type="journal">[13]	Ahmadi G. R., and Toghraie D., &quot;Energy and exergy analysis of Montazeri steam power plant in Iran”. Renewable and Sustainable Energy Reviews, 56: 454-463, (2016).</mixed-citation>
                    </ref>
                                    <ref id="ref14">
                        <label>14</label>
                        <mixed-citation publication-type="journal">[14]	Sahin A. Z., Al-Sharafi A., Yilbas B. S., and Khaliq A., &quot;Overall performance assessment of a combined cycle power plant: an exergo-economic analysis”. Energy Conversion and Management, 116: 
91-100, (2016).</mixed-citation>
                    </ref>
                                    <ref id="ref15">
                        <label>15</label>
                        <mixed-citation publication-type="journal">[15]	Aljundi I. H., “Energy and exergy analysis of a steam power plant in Jordan”. Applied Thermal Engineering, 29(2-3): 324-328, (2009).</mixed-citation>
                    </ref>
                                    <ref id="ref16">
                        <label>16</label>
                        <mixed-citation publication-type="journal">[16]	Dincer I., and Al‐Muslim H., “Thermodynamic analysis of reheat cycle steam power plants”. International Journal of Energy Research, 25(8): 727-739, (2001).</mixed-citation>
                    </ref>
                                    <ref id="ref17">
                        <label>17</label>
                        <mixed-citation publication-type="journal">[17]	Bejan A., Tsatsaronis G., and Moran M. J., “Thermal Design and Optimization” Birinci Baskı, John Wiley &amp; Sons, New York, USA, (1996).</mixed-citation>
                    </ref>
                                    <ref id="ref18">
                        <label>18</label>
                        <mixed-citation publication-type="journal">[18]	Kotas T. J., “The Exergy Method of Thermal Plant Analysis”. Birinci Baskı, Krieger, Melbourne, USA, (1985).</mixed-citation>
                    </ref>
                                    <ref id="ref19">
                        <label>19</label>
                        <mixed-citation publication-type="journal">[19]	F-chart software, www.fchart.com, Erişim tarihi: 24.03.2020</mixed-citation>
                    </ref>
                            </ref-list>