BibTex RIS Kaynak Göster

An Alternative Anti-HIV Confirmation Method: Line Immunoassay

Yıl 1998, Cilt: 4 Sayı: 1-2, - , 01.05.1998

Öz

Kaynakça

  • Hellings JA. Theunissen H. Keur W. Siebelink—Liauw A. New Developments in ELISA verification of anti—HIIII screening oi blood donors. J 'v'iroi Methods 1937: 1T: 11- ?.
  • World Health Organisation. Operational characteristics of commercially available assays to detect antibodies to Hl'v'- andfer HIV—2 in human sera. Fteport 2. Geneva 1999; GPNBMHiüüJ .
  • Blomberg J. Klasse PJ. Specificities and sensitivities ot three systems for determination of antibodies to human immunodeŞciency virus by elektrophoretic immunoblotting. J Clin Microbiol 1999; 25:196—119.
  • Britz JA. Flolon N. Hill T. Page E. Geitoski J. Interpreting HW ELISA reactivitiy: Alternatives to western blot. J Clin Lab Anal 193B: 2: 174-191. Wittwer CT. Ash KD. Evaluation of three commercial kits for the contirrnation of antibodies to human immune- defiiciency virus [HIV-1]. Clin Chem 1999; 34: 1939. s. Benesson ns. Peddecord KM. Hotnerr LK. Aseher MS.
  • Taylor FIN. Hearn TL. Reporting the results of human ImmunodeŞciency virus testing. J Am Med Assoc f99Ei; : cassettes. ?. Nranck Fi. Evaluation of a line immunoassay for the differential detection of antibodies to human immune- deficiency vims. Eur J Clin Microbiol Infect Dis 1999: a: erel-GTE.
  • B. Pollet DE. Sarnen EL. Peeters DG. Wannenbol HM. Hyendrickx LM. Wonters CJ. Beelaert G. ConŞrmation and differentiation of antibodies to human immunodeficiency virus I and II. using a strip based assay including recombinant antigens and synthetic peptides. Clin Chem : 3?: 1?eU-1?u?. Türkiye Ekoparofoji Dergisi ross; 4 (1-2): 49-51
  • LousserI—Alaita I. Ly TD. Chalk ML. Ingrand D. Saragosti S. Courouce AM. Brun-'liezinet F. Simon F. Hl’v'fliHIVaz seronegativity in HIV-1 subtype D Infected patients. Lancet : 343: 1393-1394.
  • Nkengasong J. Kerckhoven IV. Iii'ercauteren G. F'iot P. Green G. Alternative confirmatory strategy for anti-HillIr antibody detection. J viral Methods 1992: 36: 159—179.
  • Courouce AM. Muller J. Richard D. False-posidve western blot reactions to human immunodeficiency vims in blood donors. Lancet.1936: 2: 921-922.
  • Böttige B. Karisson A. Andreassen P. Envelope cross reactivity between human immunodeficiency virus types 1 and 2 detected by different serologlcal methods. Corre- lation between cross—neutralization and reactivity against the main neutralizing site. J 1v'irol . 1999; 64: 3492—9499.
  • Schmidt G Amiraian K.. Frey H. Stevens BW. Berns DS- Densitometrlc analysis of western blot [Immunobioti assay for human immunodefiiciency virus antibodies and correlation with clinical status. J Clin Microbiol 195?; 25: 1999.

Alternatif Bir Anti-HIV Doğrulama Yöntemi: "Line Immunoassay"

Yıl 1998, Cilt: 4 Sayı: 1-2, - , 01.05.1998

Öz

Bu çalışmada. hem enzyme immunoassay hem de western biot ile anti-Hiti saptanan 4G serum örneğini line immunoassay yöntemi ile değerlendirdik. Ayrıca enzyme immunoassay ile anti—Hiti olumlu. western blot ile olumsuz bulunan 24 serum örneğini de line immuno— assay ile değerlendirdik. Western blot olumlu 45 seru— mun tümü line immunoassay ile olumlu bulundu [duyarlı— lık: “Hui-DD]. Western blot olumsuz örneklerin tümü line immunoassay ile de olumsuz bulundu [özgüilük: “fal Dü )

Kaynakça

  • Hellings JA. Theunissen H. Keur W. Siebelink—Liauw A. New Developments in ELISA verification of anti—HIIII screening oi blood donors. J 'v'iroi Methods 1937: 1T: 11- ?.
  • World Health Organisation. Operational characteristics of commercially available assays to detect antibodies to Hl'v'- andfer HIV—2 in human sera. Fteport 2. Geneva 1999; GPNBMHiüüJ .
  • Blomberg J. Klasse PJ. Specificities and sensitivities ot three systems for determination of antibodies to human immunodeŞciency virus by elektrophoretic immunoblotting. J Clin Microbiol 1999; 25:196—119.
  • Britz JA. Flolon N. Hill T. Page E. Geitoski J. Interpreting HW ELISA reactivitiy: Alternatives to western blot. J Clin Lab Anal 193B: 2: 174-191. Wittwer CT. Ash KD. Evaluation of three commercial kits for the contirrnation of antibodies to human immune- defiiciency virus [HIV-1]. Clin Chem 1999; 34: 1939. s. Benesson ns. Peddecord KM. Hotnerr LK. Aseher MS.
  • Taylor FIN. Hearn TL. Reporting the results of human ImmunodeŞciency virus testing. J Am Med Assoc f99Ei; : cassettes. ?. Nranck Fi. Evaluation of a line immunoassay for the differential detection of antibodies to human immune- deficiency vims. Eur J Clin Microbiol Infect Dis 1999: a: erel-GTE.
  • B. Pollet DE. Sarnen EL. Peeters DG. Wannenbol HM. Hyendrickx LM. Wonters CJ. Beelaert G. ConŞrmation and differentiation of antibodies to human immunodeficiency virus I and II. using a strip based assay including recombinant antigens and synthetic peptides. Clin Chem : 3?: 1?eU-1?u?. Türkiye Ekoparofoji Dergisi ross; 4 (1-2): 49-51
  • LousserI—Alaita I. Ly TD. Chalk ML. Ingrand D. Saragosti S. Courouce AM. Brun-'liezinet F. Simon F. Hl’v'fliHIVaz seronegativity in HIV-1 subtype D Infected patients. Lancet : 343: 1393-1394.
  • Nkengasong J. Kerckhoven IV. Iii'ercauteren G. F'iot P. Green G. Alternative confirmatory strategy for anti-HillIr antibody detection. J viral Methods 1992: 36: 159—179.
  • Courouce AM. Muller J. Richard D. False-posidve western blot reactions to human immunodeficiency vims in blood donors. Lancet.1936: 2: 921-922.
  • Böttige B. Karisson A. Andreassen P. Envelope cross reactivity between human immunodeficiency virus types 1 and 2 detected by different serologlcal methods. Corre- lation between cross—neutralization and reactivity against the main neutralizing site. J 1v'irol . 1999; 64: 3492—9499.
  • Schmidt G Amiraian K.. Frey H. Stevens BW. Berns DS- Densitometrlc analysis of western blot [Immunobioti assay for human immunodefiiciency virus antibodies and correlation with clinical status. J Clin Microbiol 195?; 25: 1999.
Toplam 11 adet kaynakça vardır.

Ayrıntılar

Birincil Dil Türkçe
Bölüm Makaleler
Yazarlar

İrfan Sevinç Bu kişi benim

Saim Dayan Bu kişi benim

Yayımlanma Tarihi 1 Mayıs 1998
Yayımlandığı Sayı Yıl 1998 Cilt: 4 Sayı: 1-2

Kaynak Göster

APA Sevinç, İ., & Dayan, S. (1998). Alternatif Bir Anti-HIV Doğrulama Yöntemi: "Line Immunoassay". Türkiye Ekopatoloji Dergisi, 4(1-2).
AMA Sevinç İ, Dayan S. Alternatif Bir Anti-HIV Doğrulama Yöntemi: "Line Immunoassay". Türkiye Ekopatoloji Dergisi. Mayıs 1998;4(1-2).
Chicago Sevinç, İrfan, ve Saim Dayan. “Alternatif Bir Anti-HIV Doğrulama Yöntemi: ‘Line Immunoassay’”. Türkiye Ekopatoloji Dergisi 4, sy. 1-2 (Mayıs 1998).
EndNote Sevinç İ, Dayan S (01 Mayıs 1998) Alternatif Bir Anti-HIV Doğrulama Yöntemi: "Line Immunoassay". Türkiye Ekopatoloji Dergisi 4 1-2
IEEE İ. Sevinç ve S. Dayan, “Alternatif Bir Anti-HIV Doğrulama Yöntemi: ‘Line Immunoassay’”, Türkiye Ekopatoloji Dergisi, c. 4, sy. 1-2, 1998.
ISNAD Sevinç, İrfan - Dayan, Saim. “Alternatif Bir Anti-HIV Doğrulama Yöntemi: ‘Line Immunoassay’”. Türkiye Ekopatoloji Dergisi 4/1-2 (Mayıs 1998).
JAMA Sevinç İ, Dayan S. Alternatif Bir Anti-HIV Doğrulama Yöntemi: "Line Immunoassay". Türkiye Ekopatoloji Dergisi. 1998;4.
MLA Sevinç, İrfan ve Saim Dayan. “Alternatif Bir Anti-HIV Doğrulama Yöntemi: ‘Line Immunoassay’”. Türkiye Ekopatoloji Dergisi, c. 4, sy. 1-2, 1998.
Vancouver Sevinç İ, Dayan S. Alternatif Bir Anti-HIV Doğrulama Yöntemi: "Line Immunoassay". Türkiye Ekopatoloji Dergisi. 1998;4(1-2).