Research Article

The Effect of Non-uniform Pollution on the Field Distributions of Insulator String

Volume: 2 Number: 1 April 30, 2022

The Effect of Non-uniform Pollution on the Field Distributions of Insulator String

Abstract

High-voltage insulators in different atmospheres such as industrial, coastal, and desert regions are faced with temperature, heat, and conductivity changes that are difficult to predict due to factors such as wind, humidity, and precipitation. All of these lead to the formation of pollution layers with different conductivity on the insulator surface. Therefore, surface pollution is generally non-uniform. In this paper, e-field and potential distributions were investigated for non-uniform pollution by applying 20 kV to a 3-unit (U70-BLP) insulator string. The insulator string was modeled in 3D in the COMSOL Multiphysics program using the finite element method. The pollution layer was modeled by a layer of 0.5 mm thickness on the insulator surface. In uniform conditions, pollution conductivity was the same all over the surface. Non-uniform pollution was considered in two ways. First, the conductivity of the pollution was randomly distributed on the surface by forming data at certain ranges. Second, two pollution regions with different conductivity were defined, upper and bottom. The results showed that the non-uniform distribution of the pollution conductivity changed the distribution of the electric field strength and potential across the surface. The most remarkable changes were observed in the pin and cap regions where the radius of curvature was small. In regions where the pollution conductivity increased, the e-field decreased and the potential distribution approached the linear state.

Keywords

References

  1. M. A. Douar, A. Mekhaldi, and M. C. Bouzidi, “Flashover process and frequency analysis of the leakage current on insulator model under nonuniform pollution conditions,” IEEE Trans. Dielectrics Electr. Insul., vol. 17, no. 4, pp. 1284–1297, 2010.
  2. D. Pylarinos, K. Siderakis, and E. Pyrgiot, “Measuring and analyzing leakage current for outdoor insulators and specimens,” Rev. Adv. Mater. Sci., vol. 29, no. 1, pp. 31–53, 2011.
  3. S. Ilhan, A. Ozdemir, S. H. Jayaram, and E. A. Cherney, “Ac and transient electric field distributions along a 380 kV V-string insulator,” IEEE International Symposium on Electrical Insulation (ISEI), San Juan, PR, USA, 2012, pp. 399–403.
  4. S. Ilhan, A. Ozdemir, S. H. Jayaram, and E. A. Cherney, “Simulations of Pollution and their effects on the Electrical Performance of Glass Suspension Insulators,” Annual Report Conference on Electrical Insulation and Dielectric Phenomena, Montreal, QC, Canada: 2012, pp. 803–806.
  5. Z. Zhijin, Z. Jiayao, W. Donghong, and J. Xingliang, “Effects of non-uniform pollution on the AC flashover performance of suspension insulators,” J. Electr. Eng. Technol., vol. 11, no. 4, pp. 961–968, 2016.
  6. N. Kataria, and K. Tiwari, “Effect of environmental pollution on the performance of power transmission lines: Insulator’s flashover,” Int. J. Eng. Res., vol. 7, no. 4, pp. 531–533, 2018.
  7. M. T. Gençoglu, and M. Cebeci, “Investigation of pollution flashover on high voltage insulators using artificial neural network,” Expert Syst. Appl., vol. 36, no. 4, pp. 7338–7345, 2009.
  8. M. Vitelli, V. Tucci, and C. Petrarca, “Temperature distribution along an outdoor insulator subjected to different pollution levels,” IEEE Trans. Dielect. Electr. Insul., vol. 7, no. 3, pp. 416–423, 2000.

Details

Primary Language

English

Subjects

Electrical Engineering (Other)

Journal Section

Research Article

Authors

İrem Görgöz *
FIRAT ÜNİVERSİTESİ
0000-0003-2803-1119
Türkiye

Mehmet Cebeci
FIRAT ÜNİVERSİTESİ
0000-0002-2971-6788
Türkiye

Publication Date

April 30, 2022

Submission Date

February 3, 2022

Acceptance Date

March 16, 2022

Published in Issue

Year 2022 Volume: 2 Number: 1

APA
Görgöz, İ., & Cebeci, M. (2022). The Effect of Non-uniform Pollution on the Field Distributions of Insulator String. Turkish Journal of Electrical Power and Energy Systems, 2(1), 66-74. https://doi.org/10.5152/tepes.2022.21011
AMA
1.Görgöz İ, Cebeci M. The Effect of Non-uniform Pollution on the Field Distributions of Insulator String. TEPES. 2022;2(1):66-74. doi:10.5152/tepes.2022.21011
Chicago
Görgöz, İrem, and Mehmet Cebeci. 2022. “The Effect of Non-Uniform Pollution on the Field Distributions of Insulator String”. Turkish Journal of Electrical Power and Energy Systems 2 (1): 66-74. https://doi.org/10.5152/tepes.2022.21011.
EndNote
Görgöz İ, Cebeci M (April 30, 2022) The Effect of Non-uniform Pollution on the Field Distributions of Insulator String. Turkish Journal of Electrical Power and Energy Systems 2 1 66–74.
IEEE
[1]İ. Görgöz and M. Cebeci, “The Effect of Non-uniform Pollution on the Field Distributions of Insulator String”, TEPES, vol. 2, no. 1, pp. 66–74, Apr. 2022, doi: 10.5152/tepes.2022.21011.
ISNAD
Görgöz, İrem - Cebeci, Mehmet. “The Effect of Non-Uniform Pollution on the Field Distributions of Insulator String”. Turkish Journal of Electrical Power and Energy Systems 2/1 (April 30, 2022): 66-74. https://doi.org/10.5152/tepes.2022.21011.
JAMA
1.Görgöz İ, Cebeci M. The Effect of Non-uniform Pollution on the Field Distributions of Insulator String. TEPES. 2022;2:66–74.
MLA
Görgöz, İrem, and Mehmet Cebeci. “The Effect of Non-Uniform Pollution on the Field Distributions of Insulator String”. Turkish Journal of Electrical Power and Energy Systems, vol. 2, no. 1, Apr. 2022, pp. 66-74, doi:10.5152/tepes.2022.21011.
Vancouver
1.İrem Görgöz, Mehmet Cebeci. The Effect of Non-uniform Pollution on the Field Distributions of Insulator String. TEPES. 2022 Apr. 30;2(1):66-74. doi:10.5152/tepes.2022.21011

Cited By