Research Article

Experimental investigation of axial finned tube evaporator thermal distillation system using for diesel engine waste heat recovery process

Volume: 10 Number: 2 March 22, 2024
EN

Experimental investigation of axial finned tube evaporator thermal distillation system using for diesel engine waste heat recovery process

Abstract

The study aims to improve the waste thermal energy retrieval from flue gas of an internal combustion engine (ICE). The recovered waste heat energy was used for distillation by using a thermal distillation system. The performance of the thermal distillation unit was investigated by varying the evaporator (boiler) type and engine load (25, 50, 75 %). Four different types of boilers were used including one smooth copper tube and other three were two, three and four axial finned copper tube evaporators. The impact of boiler type and engine load on the net retrieved energy and exergy, net energy and exergy efficiency, and distillate yield rate of thermal distillation unit was also examined. The results showed that the net extracted heat energy and exergy for axial finned tube evaporator was approximately 26.823 – 45.513 % and 7.614 – 25.203 W higher than that of smooth tubes evaporator at 25 and 75 % engine load, respectively. The distillation yield was found to be ~ 2.35 liter/ hour in the case of four axial finned tube boiler at 75 % engine load.

Keywords

References

  1. [1] Jouhara H, Khordehgah N, Almahmoud S, Delpech B, Chauhan A, Tassou SA. Waste heat recovery technologies and applications. Therm Sci Eng Prog 2018;6:268–289. [CrossRef]
  2. [2] Forman C, Muritala IK, Pardemann R, Meyer B. Estimating the global waste heat potential. Renew Sustain Energy Rev 2016;57:1568–1579. [CrossRef]
  3. [3] Olabi AG, Elsaid K, Sayed ET, Mahmoud MS, Wilberforce T, Hassiba RJ, et al. Application of nanofluids for enhanced waste heat recovery: A review. Nano Energy 2021;84:105871. [CrossRef]
  4. [4] Klemeš JJ, Kravanja Z. Forty years of heat integration: Pinch Analysis (PA) and Mathematical Programming (MP). Curr Opin Chem Eng 2013;2:461–474. [CrossRef]
  5. [5] Moustafa HM, Nassar MM, Abdelkareem MA, Mahmoud MS, Obaid M. Synthesis of single and bimetallic oxide-doped rGO as a possible electrode for capacitive deionization. J Appl Electrochem 2020;50:745–755. [CrossRef]
  6. [6] Farhat O, Faraj J, Hachem F, Castelain C, Khaled M. A recent review on waste heat recovery methodology and applications: Comprehensive review, critical analysis and potential recommendations. Clean Engineer Technol 2022;6:100387. [CrossRef]
  7. [7] Varshil P, Deshmukh D. A comprehensive review of waste heat recovery from a diesel engine using organic rankine cycle. Energy Reports 2021;7:3951–3970. [CrossRef]
  8. [8] Hussein AK. Applications of nanotechnology in renewable energies-A comprehensive overview and understanding. Renew Sustain Energy Rev 2015;42:460–476. [CrossRef]

Details

Primary Language

English

Subjects

Thermodynamics and Statistical Physics

Journal Section

Research Article

Publication Date

March 22, 2024

Submission Date

January 29, 2022

Acceptance Date

June 11, 2022

Published in Issue

Year 2024 Volume: 10 Number: 2

APA
Kumar, S., & Chandra, P. (2024). Experimental investigation of axial finned tube evaporator thermal distillation system using for diesel engine waste heat recovery process. Journal of Thermal Engineering, 10(2), 479-489. https://doi.org/10.18186/thermal.1456708
AMA
1.Kumar S, Chandra P. Experimental investigation of axial finned tube evaporator thermal distillation system using for diesel engine waste heat recovery process. Journal of Thermal Engineering. 2024;10(2):479-489. doi:10.18186/thermal.1456708
Chicago
Kumar, Satyendra, and Prakash Chandra. 2024. “Experimental Investigation of Axial Finned Tube Evaporator Thermal Distillation System Using for Diesel Engine Waste Heat Recovery Process”. Journal of Thermal Engineering 10 (2): 479-89. https://doi.org/10.18186/thermal.1456708.
EndNote
Kumar S, Chandra P (March 1, 2024) Experimental investigation of axial finned tube evaporator thermal distillation system using for diesel engine waste heat recovery process. Journal of Thermal Engineering 10 2 479–489.
IEEE
[1]S. Kumar and P. Chandra, “Experimental investigation of axial finned tube evaporator thermal distillation system using for diesel engine waste heat recovery process”, Journal of Thermal Engineering, vol. 10, no. 2, pp. 479–489, Mar. 2024, doi: 10.18186/thermal.1456708.
ISNAD
Kumar, Satyendra - Chandra, Prakash. “Experimental Investigation of Axial Finned Tube Evaporator Thermal Distillation System Using for Diesel Engine Waste Heat Recovery Process”. Journal of Thermal Engineering 10/2 (March 1, 2024): 479-489. https://doi.org/10.18186/thermal.1456708.
JAMA
1.Kumar S, Chandra P. Experimental investigation of axial finned tube evaporator thermal distillation system using for diesel engine waste heat recovery process. Journal of Thermal Engineering. 2024;10:479–489.
MLA
Kumar, Satyendra, and Prakash Chandra. “Experimental Investigation of Axial Finned Tube Evaporator Thermal Distillation System Using for Diesel Engine Waste Heat Recovery Process”. Journal of Thermal Engineering, vol. 10, no. 2, Mar. 2024, pp. 479-8, doi:10.18186/thermal.1456708.
Vancouver
1.Satyendra Kumar, Prakash Chandra. Experimental investigation of axial finned tube evaporator thermal distillation system using for diesel engine waste heat recovery process. Journal of Thermal Engineering. 2024 Mar. 1;10(2):479-8. doi:10.18186/thermal.1456708

IMPORTANT NOTE: JOURNAL SUBMISSION LINK http://eds.yildiz.edu.tr/journal-of-thermal-engineering