Monitoring and Simulation of Mechanically Ventilated Underground Car Parks

Yıl 2015, Cilt: 1 Sayı: 5 - Cilt: 1 Sayı: 5, 295 - 302, 01.05.2015
https://doi.org/10.18186/jte.88079

Öz

Rapid motorization in developed and developing countries demands more parking spaces in urban areas. Underground car parking space in multi story buildings offers viable solution. However, lack of natural ventilation accumulates the harmful emissions from cars, operating in underground car parks. Exposure to these hazardous pollutants causes health risk to the users. Therefore, proper mechanical ventilation system should be adopted for the removal of harmful pollutants. This paper discusses the usage of modeling and simulation tools in the design of the mechanical ventilation system. Two widely used modeling techniques, multi-zone modeling and CFD modeling were used to simulate the contaminant distribution in a mechanical ventilated environment. The former provides an approximate macroscopic solution of the carbon monoxide (CO) distribution, while the later provides precise distribution of CO contours. The two models were validated against field measurements made at Chennai, India. The model predictions were very close to the actual site measurements. The impact of garage height and CO generation rate on ventilation requirement has been analysed

Kaynakça

  • Areselene, M. A., Dick, A. G. and Moncef, K., 2000. Field evaluation of ventilation system performance in enclosed parking garages. ASHRAE Transactions: Research, 106(1), pp.228-235.
  • ASHRAE, 2007. ASHRAE Handbook: HVAC Applications. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers.
  • Axley, J., 1988. Progress Toward a general analytical method for predicting indoor air pollution in Buildings – Indor Air Quality Modeling. Phase III Report. Gaithersburg: National Institute of Standards and Technology.
  • Chan, M.Y., Burnett, J. and Chow, W.K., 1997. to Personal

Monitoring and Simulation of Mechanically Ventilated Underground Car Parks

Yıl 2015, Cilt: 1 Sayı: 5 - Cilt: 1 Sayı: 5, 295 - 302, 01.05.2015
https://doi.org/10.18186/jte.88079

Öz

Kaynakça

  • Areselene, M. A., Dick, A. G. and Moncef, K., 2000. Field evaluation of ventilation system performance in enclosed parking garages. ASHRAE Transactions: Research, 106(1), pp.228-235.
  • ASHRAE, 2007. ASHRAE Handbook: HVAC Applications. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers.
  • Axley, J., 1988. Progress Toward a general analytical method for predicting indoor air pollution in Buildings – Indor Air Quality Modeling. Phase III Report. Gaithersburg: National Institute of Standards and Technology.
  • Chan, M.Y., Burnett, J. and Chow, W.K., 1997. to Personal
Toplam 4 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Bölüm Makaleler
Yazarlar

Adil Eshack Bu kişi benim

Leo Samuel D.g. Bu kişi benim

Shiva Nagendra S.m. Bu kişi benim

M. Prakash Maiya Bu kişi benim

Yayımlanma Tarihi 1 Mayıs 2015
Gönderilme Tarihi 14 Mayıs 2015
Yayımlandığı Sayı Yıl 2015 Cilt: 1 Sayı: 5 - Cilt: 1 Sayı: 5

Kaynak Göster

APA Eshack, A., D.g., L. S., S.m., S. N., Maiya, M. P. (2015). Monitoring and Simulation of Mechanically Ventilated Underground Car Parks. Journal of Thermal Engineering, 1(5), 295-302. https://doi.org/10.18186/jte.88079
AMA Eshack A, D.g. LS, S.m. SN, Maiya MP. Monitoring and Simulation of Mechanically Ventilated Underground Car Parks. Journal of Thermal Engineering. Mayıs 2015;1(5):295-302. doi:10.18186/jte.88079
Chicago Eshack, Adil, Leo Samuel D.g., Shiva Nagendra S.m., ve M. Prakash Maiya. “Monitoring and Simulation of Mechanically Ventilated Underground Car Parks”. Journal of Thermal Engineering 1, sy. 5 (Mayıs 2015): 295-302. https://doi.org/10.18186/jte.88079.
EndNote Eshack A, D.g. LS, S.m. SN, Maiya MP (01 Mayıs 2015) Monitoring and Simulation of Mechanically Ventilated Underground Car Parks. Journal of Thermal Engineering 1 5 295–302.
IEEE A. Eshack, L. S. D.g., S. N. S.m., ve M. P. Maiya, “Monitoring and Simulation of Mechanically Ventilated Underground Car Parks”, Journal of Thermal Engineering, c. 1, sy. 5, ss. 295–302, 2015, doi: 10.18186/jte.88079.
ISNAD Eshack, Adil vd. “Monitoring and Simulation of Mechanically Ventilated Underground Car Parks”. Journal of Thermal Engineering 1/5 (Mayıs 2015), 295-302. https://doi.org/10.18186/jte.88079.
JAMA Eshack A, D.g. LS, S.m. SN, Maiya MP. Monitoring and Simulation of Mechanically Ventilated Underground Car Parks. Journal of Thermal Engineering. 2015;1:295–302.
MLA Eshack, Adil vd. “Monitoring and Simulation of Mechanically Ventilated Underground Car Parks”. Journal of Thermal Engineering, c. 1, sy. 5, 2015, ss. 295-02, doi:10.18186/jte.88079.
Vancouver Eshack A, D.g. LS, S.m. SN, Maiya MP. Monitoring and Simulation of Mechanically Ventilated Underground Car Parks. Journal of Thermal Engineering. 2015;1(5):295-302.

IMPORTANT NOTE: JOURNAL SUBMISSION LINK http://eds.yildiz.edu.tr/journal-of-thermal-engineering