An experimental investigation has been carried
out for a range of system and operating parameters in
order to analyze effect of artificial roughness on heat
transfer and friction in solar air heater duct having
triangular protrusions as roughness geometry. An
increase in heat transfer and friction loss has been
observed in solar for duct having roughened absorber
plate. Experimental data have been used to develop
Nusselt number and friction factor correlations as
function of system and operating parameters for
predicting performance of the system having
investigated type of roughness geometry.
Birincil Dil | İngilizce |
---|---|
Bölüm | Makaleler |
Yazarlar | |
Yayımlanma Tarihi | 6 Haziran 2016 |
Gönderilme Tarihi | 23 Ekim 2015 |
Yayımlandığı Sayı | Yıl 2015 Cilt: 1 Sayı: 7 |
IMPORTANT NOTE: JOURNAL SUBMISSION LINK http://eds.yildiz.edu.tr/journal-of-thermal-engineering