                <article-meta>
                                        <article-id pub-id-type="doi">10.51435/turkjac.1132742</article-id>
                                                                <article-categories>
                                            <subj-group  xml:lang="en">
                                                            <subject>Analytical Chemistry</subject>
                                                    </subj-group>
                                            <subj-group  xml:lang="tr">
                                                            <subject>Analitik Kimya</subject>
                                                    </subj-group>
                                    </article-categories>
                                                                                                                                                        <title-group>
                                                                                                                                                            <article-title>Electrochemical and liquid chromatographic analysis of triamcinolone acetonide in pharmaceutical formulations</article-title>
                                                                                                    </title-group>
            
                                                    <contrib-group content-type="authors">
                                                                        <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0000-0003-3067-3954</contrib-id>
                                                                <name>
                                    <surname>Denizhan</surname>
                                    <given-names>Nuray</given-names>
                                </name>
                                                                    <aff>CANAKKALE ONSEKIZ MART UNIVERSITY</aff>
                                                            </contrib>
                                                    <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0000-0003-4607-3523</contrib-id>
                                                                <name>
                                    <surname>Yılmaz</surname>
                                    <given-names>Selehattin</given-names>
                                </name>
                                                                    <aff>Canakkale Onsekiz Mart Universty, Faculty of Science And Arts, Department of Chemistry</aff>
                                                            </contrib>
                                                    <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0000-0002-3407-9787</contrib-id>
                                                                <name>
                                    <surname>Sağlıkoğlu</surname>
                                    <given-names>Gülşen</given-names>
                                </name>
                                                                    <aff>CANAKKALE ONSEKIZ MART UNIVERSITY</aff>
                                                            </contrib>
                                                    <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0000-0002-4583-8371</contrib-id>
                                                                <name>
                                    <surname>Kılınç</surname>
                                    <given-names>Emrah</given-names>
                                </name>
                                                                    <aff>EGE ÜNİVERSİTESİ, ECZACILIK FAKÜLTESİ</aff>
                                                            </contrib>
                                                    <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0000-0002-1353-7355</contrib-id>
                                                                <name>
                                    <surname>Yengin</surname>
                                    <given-names>Çiğdem</given-names>
                                </name>
                                                                    <aff>EGE ÜNİVERSİTESİ, ECZACILIK FAKÜLTESİ</aff>
                                                            </contrib>
                                                    <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0000-0002-2515-8846</contrib-id>
                                                                <name>
                                    <surname>Der</surname>
                                    <given-names>Fatma Gülay</given-names>
                                </name>
                                                                    <aff>EGE ÜNİVERSİTESİ, ECZACILIK FAKÜLTESİ</aff>
                                                            </contrib>
                                                                                </contrib-group>
                        
                                        <pub-date pub-type="pub" iso-8601-date="20221229">
                    <day>12</day>
                    <month>29</month>
                    <year>2022</year>
                </pub-date>
                                        <volume>4</volume>
                                        <issue>2</issue>
                                        <fpage>59</fpage>
                                        <lpage>66</lpage>
                        
                        <history>
                                    <date date-type="received" iso-8601-date="20220619">
                        <day>06</day>
                        <month>19</month>
                        <year>2022</year>
                    </date>
                                                    <date date-type="accepted" iso-8601-date="20221002">
                        <day>10</day>
                        <month>02</month>
                        <year>2022</year>
                    </date>
                            </history>
                                        <permissions>
                    <copyright-statement>Copyright © 2019, Turkish Journal of Analytical Chemistry</copyright-statement>
                    <copyright-year>2019</copyright-year>
                    <copyright-holder>Turkish Journal of Analytical Chemistry</copyright-holder>
                </permissions>
            
                                                                                                                        <abstract><p>Electrochemical reduction of triamcinolone acetonide on pencil graphite electrode surface was firstly investigated by cyclic voltammetry (CV). The dependence of cathodic peak current and peak potential on different pH medium and scan rate were investigated. The adsorption controlled nature of the peak was achieved. During pH optimization, 0.067 M Phosphate  (pH 4.50 to pH 7.50), 0.2 M Acetate  (pH 3.50 to 5.50) and 0.04 M Britton Robinson (BR; pH 2.00 to 12.00) buffers were employed as supporting electrolytes. Scan rate optimization was investigated in the range 25-1000 mVs-1 (vs. Ag/AgCl). Maximum peak current was observed in the 0.04 M BR buffer (pH 3.50). Peak current increases and shifts to more cathodic values with the increasing scan rate. Curve of logarithm of peak current (log I) versus logarithm of scan rate (log v) showed linear regression with the equation log(Ip/μA) = 0.8395 log(v/mVs-1)-0.8386  and correlation coefficient (R2: 0.9761). This indicated that slope of the logv-logI curve is close to 1.0 and the cathodic electrode reaction was adsorption controlled, as desirable. The linear range was 1×10-7-5×10-5 M, sensitivity was 1,3347 µA M-1, Limit of detection (LOD) and Limit of quantification (LOQ) were   3.18×10-8 M and 1.00×10-7 M, respectively. HPLC-PDA analysis were performed with H2O:MeOH (28:72, v/v) as mobile phases A and B at a flow rate of 1mL/min at 242nm. Method validation studies were conducted in accordance with ICH Q2(R1) guideline and corresponding results were summarized in tables. HPLC-PDA method displayed linearity in 0.1-50µg/mL (2.3×10-7-1.15×10-4 M) concentration range with LOD and LOQ values as 3.992×10-8 and 1.29×10-7M, respectively.</p></abstract>
                                                            
            
                                                                                        <kwd-group>
                                                    <kwd>Triamcinolone acetonide</kwd>
                                                    <kwd>  voltammetry</kwd>
                                                    <kwd>  HPLC-PDA</kwd>
                                                    <kwd>  pencil graphite electrode.</kwd>
                                            </kwd-group>
                            
                                                                                                                                                    </article-meta>
    </front>
    <back>
                            <ref-list>
                                    <ref id="ref1">
                        <label>1</label>
                        <mixed-citation publication-type="journal">[1] The International Olympic Committee (IOC) “Anti-Doping Rules Applicable to the Games of the XXIX Olympiad”, 2008, 3-9.</mixed-citation>
                    </ref>
                                    <ref id="ref2">
                        <label>2</label>
                        <mixed-citation publication-type="journal">[2] H. Koç, O. Yüksel, Kadınlarda fiziksel ve fizyolojik performansının değerlendirilmesi, Dumlupınar Üniversitesi Sağlık Bilimleri Dergisi, 9, 2007, 1.</mixed-citation>
                    </ref>
                                    <ref id="ref3">
                        <label>3</label>
                        <mixed-citation publication-type="journal">[3] A.J.P. van Heugtena,  W. de Boer, W.S. de Vries, C.M.A. Markesteijn, H. Vromans, Development and validation of a stability-indicating HPLC-UV method for the determination of triamcinolone acetonide and its degradation products in an ointment formulation, J Pharm Biomed Anal, 149, 2018, 149, 265.</mixed-citation>
                    </ref>
                                    <ref id="ref4">
                        <label>4</label>
                        <mixed-citation publication-type="journal">[4] S. Sudsakorn, L. Kaplan, D.A. Williams, Simultaneous determination of triamcinolone acetonide and oxymetazoline hydrochloride in nasal spray formulations by HPLC, J Pharm Biomed Anal, 40, 2006, 1273.</mixed-citation>
                    </ref>
                                    <ref id="ref5">
                        <label>5</label>
                        <mixed-citation publication-type="journal">[5] G.M. Fernandes-Cunha, J.B. Saliba, R.C. Siqueira, R. Jorge, A. Silva-Cunha, Determination of triamcinolone acetonide in silicone oil and aqueous humor of vitrectomized rabbits’ eyes: Application for a pharmacokinetic study with intravitreal triamcinolone acetonide injections (Kenalog®40), J Pharm Biomed Anal, 89, 2014, 24.</mixed-citation>
                    </ref>
                                    <ref id="ref6">
                        <label>6</label>
                        <mixed-citation publication-type="journal">[6] D. De Orsi, M. Pellegrini, S. Pichini, D. Mattioli, E. Marchei, L. Gagliardi, High-performance liquid chromatography–diode array and electrospray-mass spectrometry analysis of non-allowed substances in cosmetic products for preventing hair loss and other hormone-dependent skin diseases, J Pharm Biomed Anal, 48, 2008, 641.</mixed-citation>
                    </ref>
                                    <ref id="ref7">
                        <label>7</label>
                        <mixed-citation publication-type="journal">[7] S.A. Doppenschmitt, B. Scheidel, F. Harrison, J.P. Surmann, Simultaneous determination of triamcinolone acetonide and hydrocortisone in human plasma by high-performance liquid chromatography, J Chromatogr B: Biomed Sci Appl, 682, 1996, 79.</mixed-citation>
                    </ref>
                                    <ref id="ref8">
                        <label>8</label>
                        <mixed-citation publication-type="journal">[8] A.M. di Pietra, V. Andrisano, R. Gotti, V. Cavrini, On-line post-column photochemical derivatization in liquid chromatographic-diode-array detection analysis of binary drug mixtures, J Pharm Biomed Anal, 14, 1996, 1191.</mixed-citation>
                    </ref>
                                    <ref id="ref9">
                        <label>9</label>
                        <mixed-citation publication-type="journal">[9] H. Tokunaga, T. Kimura, J. Kawamura, Gas chromatographic determination of glucocorticoids as trimethylsilyl ether derivatives, Yakugaku Zasshi, 99(8), 1979, 800.</mixed-citation>
                    </ref>
                                    <ref id="ref10">
                        <label>10</label>
                        <mixed-citation publication-type="journal">[10] D. Agbaba, D. Zivanov-Stakic, S. Vladimirov, K. Zubac, Determination of triamcinolone, triamcinolone acetonide and fluocinonide in dosage forms, Acta Pol Pharm, 47(1-2), 1990, 15-18.</mixed-citation>
                    </ref>
                                    <ref id="ref11">
                        <label>11</label>
                        <mixed-citation publication-type="journal">[11] E.R.M. Kedor-Hackmann, E.A.S. Gianotto, M.I.R.M. Santoro, Determination of triamcinolone acetonide in ointment by UV derivative spectrophotometry and high performance liquid chromatography, Anal Lett, 30(10), 1997, 1861.</mixed-citation>
                    </ref>
                                    <ref id="ref12">
                        <label>12</label>
                        <mixed-citation publication-type="journal">[12] Y.S. El-Saharty, N.Y. Hassan, F.H. Metwally, Simultaneous determination of terbinafine HCl and triamcinolone acetonide by UV derivative spectrophotometry and spectrodensitometry, J Pharm Biomed Anal, 28(3-4), 2002, 569.</mixed-citation>
                    </ref>
                                    <ref id="ref13">
                        <label>13</label>
                        <mixed-citation publication-type="journal">[13] E. Hammam, Determination of triamcinolone acetonide in pharmaceutical formulation and human serum by adsorptive cathodic stripping voltammetry, Chem. Anal. (Warsaw, Pol.), 52, 2007, 43.</mixed-citation>
                    </ref>
                                    <ref id="ref14">
                        <label>14</label>
                        <mixed-citation publication-type="journal">[14] C. Vedhi, R. Eswar, H.G. Prabu, P. Manisankar, Determination of triamcinolone acetonide steroid on glassy carbon electrode by stripping voltammetric methods, Int J Electrochem Sci, 3, 2008, 509.</mixed-citation>
                    </ref>
                                    <ref id="ref15">
                        <label>15</label>
                        <mixed-citation publication-type="journal">[15] R.N. Goyal, V.K. Gupta, S. Chatterjee, A sensitive voltammetric sensor for determination of synthetic corticosteroid triamcinolone, abused for doping, Biosens Bioelectron, 24, 2009, 3562.</mixed-citation>
                    </ref>
                                    <ref id="ref16">
                        <label>16</label>
                        <mixed-citation publication-type="journal">[16] P. Kabasakalian, J. McGlotten, The polarographic reduction of prednisone (17,21-Dihydroxy-l,4-pregnadiene-3,11,20-trione), prednisolone (11,17,21-Trihydroxy-1,4-pregnadiene-3,20-dione) and their precursors, J Am Chem Soc, 78(19), 1956, 5032.</mixed-citation>
                    </ref>
                                    <ref id="ref17">
                        <label>17</label>
                        <mixed-citation publication-type="journal">[17] P.M. Zagrzewski, K.N. Belikov, I.A. Zinchenko, The study of the electrochemical behavior of triamcinolone acetonide on the carbon paste electrodes for its voltammetric determination, Methods Objects Chem Anal, 13(3), 2018, 136.</mixed-citation>
                    </ref>
                                    <ref id="ref18">
                        <label>18</label>
                        <mixed-citation publication-type="journal">[18] M.M. Baker, T.S. Belal, M.S. Mahrous, H.M. Ahmed, H.G. Daabees, A validated stability-indicating HPLC-DAD method for simultaneous determination of econazole nitrate, triamcinolone acetonide, benzoic acid and butylated hydroxyanisole in cream dosage form, Analytical Methods, 9, 2016, 2185.</mixed-citation>
                    </ref>
                                    <ref id="ref19">
                        <label>19</label>
                        <mixed-citation publication-type="journal">[19] M. Sigg, R. Daniels, The effect of alkanediols on the release of triamcinolone acetonide from semisolid dosage forms, Int J Pharm, 605, 2021, 120843.</mixed-citation>
                    </ref>
                                    <ref id="ref20">
                        <label>20</label>
                        <mixed-citation publication-type="journal">[20] M.M. Sebaiy, S.M. El-Adl, M.M. Baraka, M.S. Mohram, Y.M. Elkady, Stability indicating HPLC method for the simultaneous estimation of triamcinolone acetonide and benzyl alcohol in pure form and Epirelefan® vial, Am J Med Chem, 2(1), 2020, 4.</mixed-citation>
                    </ref>
                                    <ref id="ref21">
                        <label>21</label>
                        <mixed-citation publication-type="journal">[21]  M. Márquez Valls, A. Martínez Labrador, L. Halbaut Bellowa, D. Bravo Torres, P.C. Granda, M. Miñarro Carmona, D. Limón, A.C. Calpena Campmany, Biopharmaceutical Study of Triamcinolone Acetonide Semisolid Formulations for Sublingual and Buccal Administration, Pharmaceutics, 13, 2021, 1080.</mixed-citation>
                    </ref>
                            </ref-list>
                    </back>
    </article>