Yıl 2025,
Cilt: 24 Sayı: 1, 45 - 46, 29.04.2025
Deha Çetin
,
Mustafa Harı
,
Bünyamin Sarıtaş
Öz
Endoklipler, gastroenteroloji pratiğinde 40 yıldan uzun süredir kullanılan cihazlardır. Genellikle varis dışı üst gastrointestinal system kanamalarında kullanılırlar. Endoklipler genellikle birkaç hafta içerisinde düşerler. Burada 20 aya yakın düşmeyen bir endoklip vakasını sunuyoruz.
Kaynakça
- 1. Raju GS, Gajula L. Endoclips for GI endoscopy. Gastrointest Endosc. 2004;59(2):267-79.
- 2. Swellengrebel HA, Marijnen CA, Vincent A, Cats A. Evaluating long-term attachment of two different endoclips in the human gastrointestinal tract. World J Gastrointest Endosc. 2010;2(10):344-8.
- 3. Olmez S, Ozaslan E, Avcioglu U. Hemoclip retained for more than 2 years. Endoscopy. 2012;44(Suppl 2)UCTN:E323-4.
- 4. Ooi BP, Hassan MR, Kiew KK, Chin KL, Zalwani Z. Case report of a hemostatic clip being retained for 2 years after deployment. Gastrointest Endosc. 2010;72(6):1315-6.
- 5. Shin DY, Park S, Kim A, Kim ES, Jeon HH. Compatibility of endoclips in the gastrointestinal tract with magnetic resonance imaging. Sci Rep. 2020;10(1):16537.
- 6. Accorsi F, Coutu G, Simms EL, Lalonde A, Leswick DA. Endoscopic Clip MRI Screening: A Canada-Wide Policy Survey. AJR Am J Roentgenol. 2017;209(1):130-135.
- 7. Lim BS, Pirianka Y, Agathon G. Lolli-Polyp: Demonstration of Two Methods for Removal of Retained Endoclips. Gastrointestinal Endoscopy 2016;83(55):AB639.
- 8. Accorsi F, Lalonde A, Leswick DA. Endoclip Magnetic Resonance Imaging Screening: A Local Practice Review. Can Assoc Radiol J. 2018;69(2):162-8.
- 9. Ginsberg GG, Lipman TO, Fleischer DE. Endoscopic clip-assisted placement of enteral feeding tubes. Gastrointest Endosc. 1994;40(2 Pt 1):220-2.
Retained endoclip: A rare case report
Yıl 2025,
Cilt: 24 Sayı: 1, 45 - 46, 29.04.2025
Deha Çetin
,
Mustafa Harı
,
Bünyamin Sarıtaş
Öz
Endoclips are used devices in gastroenterology practice for more than 40 years. Endoclips are widely used devices to treat non-variceal bleedings. They are usually detached within a few weeks. Here we report a case of retained endoclip for almost 20 months.
Kaynakça
- 1. Raju GS, Gajula L. Endoclips for GI endoscopy. Gastrointest Endosc. 2004;59(2):267-79.
- 2. Swellengrebel HA, Marijnen CA, Vincent A, Cats A. Evaluating long-term attachment of two different endoclips in the human gastrointestinal tract. World J Gastrointest Endosc. 2010;2(10):344-8.
- 3. Olmez S, Ozaslan E, Avcioglu U. Hemoclip retained for more than 2 years. Endoscopy. 2012;44(Suppl 2)UCTN:E323-4.
- 4. Ooi BP, Hassan MR, Kiew KK, Chin KL, Zalwani Z. Case report of a hemostatic clip being retained for 2 years after deployment. Gastrointest Endosc. 2010;72(6):1315-6.
- 5. Shin DY, Park S, Kim A, Kim ES, Jeon HH. Compatibility of endoclips in the gastrointestinal tract with magnetic resonance imaging. Sci Rep. 2020;10(1):16537.
- 6. Accorsi F, Coutu G, Simms EL, Lalonde A, Leswick DA. Endoscopic Clip MRI Screening: A Canada-Wide Policy Survey. AJR Am J Roentgenol. 2017;209(1):130-135.
- 7. Lim BS, Pirianka Y, Agathon G. Lolli-Polyp: Demonstration of Two Methods for Removal of Retained Endoclips. Gastrointestinal Endoscopy 2016;83(55):AB639.
- 8. Accorsi F, Lalonde A, Leswick DA. Endoclip Magnetic Resonance Imaging Screening: A Local Practice Review. Can Assoc Radiol J. 2018;69(2):162-8.
- 9. Ginsberg GG, Lipman TO, Fleischer DE. Endoscopic clip-assisted placement of enteral feeding tubes. Gastrointest Endosc. 1994;40(2 Pt 1):220-2.