BibTex RIS Kaynak Göster

POSITION OPTIMISATION OF GE DETECTORS IN NUCLEAR RESONANCE FLUORESCENCE (NRF) EXPERIMENT BY USING MONTE CARLO METHOD

Yıl 2016, Cilt: 6 Sayı: 2, 79 - 81, 23.07.2016

Öz

Nuclear resonance fluorescence (NRF) supplies good information to study nuclear structure of isotopes. The main perquisite for excitation to occur, the incoming photon must have energy equal to one of the excited states of absorbing nucleus. After absorption of the photon, nucleus will have a transition to the excited state pertaining to photon energy and then the excited nucleus will decay back to the ground state by emitting a gamma ray that has energy equal to that excited state. This process is called nuclear resonance fluorescence (NRF). In this study, we estimated the optimum detector position by considering maximum photondetector interaction and counted photon amount. It can be concluded that maximum photon fluence is recorded at the under of the NRF target

Yıl 2016, Cilt: 6 Sayı: 2, 79 - 81, 23.07.2016

Öz

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Diğer ID JA56BY36SB
Bölüm Makaleler
Yazarlar

Hüseyin Ozan Tekin Bu kişi benim

Iskender Akkurt Bu kişi benim

Yayımlanma Tarihi 23 Temmuz 2016
Yayımlandığı Sayı Yıl 2016 Cilt: 6 Sayı: 2

Kaynak Göster

APA Tekin, H. O., & Akkurt, I. (2016). POSITION OPTIMISATION OF GE DETECTORS IN NUCLEAR RESONANCE FLUORESCENCE (NRF) EXPERIMENT BY USING MONTE CARLO METHOD. TOJSAT, 6(2), 79-81.
AMA Tekin HO, Akkurt I. POSITION OPTIMISATION OF GE DETECTORS IN NUCLEAR RESONANCE FLUORESCENCE (NRF) EXPERIMENT BY USING MONTE CARLO METHOD. TOJSAT. Temmuz 2016;6(2):79-81.
Chicago Tekin, Hüseyin Ozan, ve Iskender Akkurt. “POSITION OPTIMISATION OF GE DETECTORS IN NUCLEAR RESONANCE FLUORESCENCE (NRF) EXPERIMENT BY USING MONTE CARLO METHOD”. TOJSAT 6, sy. 2 (Temmuz 2016): 79-81.
EndNote Tekin HO, Akkurt I (01 Temmuz 2016) POSITION OPTIMISATION OF GE DETECTORS IN NUCLEAR RESONANCE FLUORESCENCE (NRF) EXPERIMENT BY USING MONTE CARLO METHOD. TOJSAT 6 2 79–81.
IEEE H. O. Tekin ve I. Akkurt, “POSITION OPTIMISATION OF GE DETECTORS IN NUCLEAR RESONANCE FLUORESCENCE (NRF) EXPERIMENT BY USING MONTE CARLO METHOD”, TOJSAT, c. 6, sy. 2, ss. 79–81, 2016.
ISNAD Tekin, Hüseyin Ozan - Akkurt, Iskender. “POSITION OPTIMISATION OF GE DETECTORS IN NUCLEAR RESONANCE FLUORESCENCE (NRF) EXPERIMENT BY USING MONTE CARLO METHOD”. TOJSAT 6/2 (Temmuz 2016), 79-81.
JAMA Tekin HO, Akkurt I. POSITION OPTIMISATION OF GE DETECTORS IN NUCLEAR RESONANCE FLUORESCENCE (NRF) EXPERIMENT BY USING MONTE CARLO METHOD. TOJSAT. 2016;6:79–81.
MLA Tekin, Hüseyin Ozan ve Iskender Akkurt. “POSITION OPTIMISATION OF GE DETECTORS IN NUCLEAR RESONANCE FLUORESCENCE (NRF) EXPERIMENT BY USING MONTE CARLO METHOD”. TOJSAT, c. 6, sy. 2, 2016, ss. 79-81.
Vancouver Tekin HO, Akkurt I. POSITION OPTIMISATION OF GE DETECTORS IN NUCLEAR RESONANCE FLUORESCENCE (NRF) EXPERIMENT BY USING MONTE CARLO METHOD. TOJSAT. 2016;6(2):79-81.