Combined method of energy and power calibration in optical range
Year 2020,
Volume: 4 Issue: 3, 1 - 7, 17.07.2020
Anna Shulga
,
Eduard Kuvaldin
Abstract
The method of calibration using calculation of measured optical radiation power in units of radiation energy and backward is presented. The method permits calibration of energy and power meters in range of 8 - 10 orders of magnitude. Comparison detector allows to calibrate energy and power meters and radiation sources via self-calibrated photodiode.
References
- Parr Albert C. The Candela and Photometric and Radiometric Measurements. Journal of Research of the National Institute of Standards and Technology, V. 106, I. 1, pp. 151-186.
- Shulga A.A. Calibrated attenuator of laser radiation. Trudy XIII Mezhdunarodnoi Conferencii “Prikladnaya optika-2018” [Proceedings of XIII international conference "Applied optics-2018"]. St. Petersburg, 2018, v. 2, pp. 34-39 (in Russian).
- Kuvaldin E.V. Counting Method for Measuring and Linearity Checking Photometry Devices. Measurement science review, 2010, v. 10, no. 2, pp. 60-62. Available at: http://www.measurement.sk/2010/S1/p.html (Accessed 17 May 2019).
- Kuvaldin E. V. Calibration of Radiation Sources and Detectors Over a Broad Range of Measurement of the Energy of Optical Radiation. Measurement Techniques, V. 61, I. 8, pp. 1-6. DOI: 10.1007/s11018-019-01567-4.
- Kuvaldin E.V., Shulga A.A. Calibration of radiant power meters for wide range. Trudy XIII Mezhdunarodnoi Conferencii “Prikladnaya optika-2018” [Proceedings of XIII international conference "Applied optics-2018"]. St. Petersburg, 2018, v. 2, pp. 148-152 (in Russian).
- Kuvaldin E.V. Portable roughness meter of mirror surface. Opticheskii Zhurnal [Journal of Optical Technolgy], 2019, no. 5, pp. 78-81 [in Russian].
- CIE 127:2007 Measurement of LEDs
- Kirgetov M. V., Kuvaldin E. V. Method of Automatic Measurement Equivalent Diameter of Scattering Circle and Finding the Plane of the Best Image in Lens. Asian Basic and Applied Research Journal, V. 1, I. 1, pp. 14- 20.
Year 2020,
Volume: 4 Issue: 3, 1 - 7, 17.07.2020
Anna Shulga
,
Eduard Kuvaldin
References
- Parr Albert C. The Candela and Photometric and Radiometric Measurements. Journal of Research of the National Institute of Standards and Technology, V. 106, I. 1, pp. 151-186.
- Shulga A.A. Calibrated attenuator of laser radiation. Trudy XIII Mezhdunarodnoi Conferencii “Prikladnaya optika-2018” [Proceedings of XIII international conference "Applied optics-2018"]. St. Petersburg, 2018, v. 2, pp. 34-39 (in Russian).
- Kuvaldin E.V. Counting Method for Measuring and Linearity Checking Photometry Devices. Measurement science review, 2010, v. 10, no. 2, pp. 60-62. Available at: http://www.measurement.sk/2010/S1/p.html (Accessed 17 May 2019).
- Kuvaldin E. V. Calibration of Radiation Sources and Detectors Over a Broad Range of Measurement of the Energy of Optical Radiation. Measurement Techniques, V. 61, I. 8, pp. 1-6. DOI: 10.1007/s11018-019-01567-4.
- Kuvaldin E.V., Shulga A.A. Calibration of radiant power meters for wide range. Trudy XIII Mezhdunarodnoi Conferencii “Prikladnaya optika-2018” [Proceedings of XIII international conference "Applied optics-2018"]. St. Petersburg, 2018, v. 2, pp. 148-152 (in Russian).
- Kuvaldin E.V. Portable roughness meter of mirror surface. Opticheskii Zhurnal [Journal of Optical Technolgy], 2019, no. 5, pp. 78-81 [in Russian].
- CIE 127:2007 Measurement of LEDs
- Kirgetov M. V., Kuvaldin E. V. Method of Automatic Measurement Equivalent Diameter of Scattering Circle and Finding the Plane of the Best Image in Lens. Asian Basic and Applied Research Journal, V. 1, I. 1, pp. 14- 20.