BibTex RIS Cite

The Effect of the Evacuated Tube Collectors on Solar Pond Performance

Year 2014, Volume: 4 Issue: 1, 1 - 10, 28.11.2014
https://izlik.org/JA67ES86SK

Abstract

The present study deals with the effect of the evacuated tube solar collectors on the heat storage performance of a solar pond. For the experimental work, a solar pond system with a radius of 0.80 m and a depth of 1.60 m and four evacuated tube solar collectors was built in Cukurova University in Adana, Turkey. Heat energy collected by evacuated tube solar collectors was transferred to the solar pond storage zone by using a heat exchanger system. The temperature and density distribution of the system were measured by using thermocouples and hydrometers. Experimental studies were performed by using 1, 2, 3 and 4 evacuated tube solar collectors. As a result, the temperature increases in the solar pond were determined as 1.56, 2.37, 3.45 and 4.01 °C for 1, 2, 3 and 4 collectors, respectively. It is seen that the temperature of the solar pond has increased from 15 °C to 25 °C within four days.

References

  • N. Kılıç, Yenilenebilir Enerji Kaynakları, Ar-Ge Bülten Mart-Sektörel, İzmir Ticaret Odası, 2008.
  • M.A. Ersöz, A. Yıldız, Tesisat Mühendisliği, 2013, 133, 5.
  • M. Karakilcik, I. Dincer, I. Bozkurt, A. Atiz, Energy Convers Manage, 2013, 65, 98. M. Karakilcik, I. Dincer, M.A. Rosen, Appl Thermal Eng, 2006, 26, 727.
  • M. Karakilcik, K. Kıymac, I. Dincer, Int J Heat Mass Transfer, 2006, 49, 825.
  • M. Karakilcik, I. Dincer, Int J Thermal Sciences, 2008, 47, 93.
  • N. Sharma, G. Diaz, Solar Energy, 2011, 85, 881.
  • I. Bozkurt, M. Karakilcik, Solar Energy, 2012, 86, 1611.
  • M. Karakilcik, I. Bozkurt, I. Dincer, Int J Exergy, 2013, 12, 70.
  • I. Bozkurt, A. Atiz, M. Karakilcik, I. Dincer, Int J Green Energy, 2014, 11, 404.

Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi

Year 2014, Volume: 4 Issue: 1, 1 - 10, 28.11.2014
https://izlik.org/JA67ES86SK

Abstract

Bu çalışma vakum tüplü güneş kollektörlerinin güneş havuzunun ısı depolama performansı üzerine etkisi ile ilgilidir. Deneysel çalışma için, 0.80 m yarıçaplı, 1.60 m derinlikli ve dört vakum tüplü güneş kollektörlü bir güneş havuzu sistemi Çukurova Üniversitesi, Adana, Türkiye’de kurulmuştur. Vakum tüplü güneş kollektörleri tarafından toplanan ısı enerjisi bir ısı değiştirici sistem kullanılarak güneş havuzunun depolama bölgesine transfer edilmiştir. Sistemin sıcaklık ve yoğunluk dağılımları ısıl çiftler ve hidrometreler kullanılarak ölçülmüştür. Deneysel çalışmalar 1, 2, 3 ve 4 vakum tüplü güneş kollektörü kullanılarak gerçekleştirilmiştir. Sonuç olarak, güneş havuzundaki sıcaklık artışları 1, 2, 3 ve 4 kollektör için sırasıyla 1.56, 2.37, 3.45 ve 4.01 °C olarak belirlenmiştir. Güneş havuzunun sıcaklığının dört gün içerisinde 15 °C’den 25 °C’ye kadar arttığı görülmüştür.

References

  • N. Kılıç, Yenilenebilir Enerji Kaynakları, Ar-Ge Bülten Mart-Sektörel, İzmir Ticaret Odası, 2008.
  • M.A. Ersöz, A. Yıldız, Tesisat Mühendisliği, 2013, 133, 5.
  • M. Karakilcik, I. Dincer, I. Bozkurt, A. Atiz, Energy Convers Manage, 2013, 65, 98. M. Karakilcik, I. Dincer, M.A. Rosen, Appl Thermal Eng, 2006, 26, 727.
  • M. Karakilcik, K. Kıymac, I. Dincer, Int J Heat Mass Transfer, 2006, 49, 825.
  • M. Karakilcik, I. Dincer, Int J Thermal Sciences, 2008, 47, 93.
  • N. Sharma, G. Diaz, Solar Energy, 2011, 85, 881.
  • I. Bozkurt, M. Karakilcik, Solar Energy, 2012, 86, 1611.
  • M. Karakilcik, I. Bozkurt, I. Dincer, Int J Exergy, 2013, 12, 70.
  • I. Bozkurt, A. Atiz, M. Karakilcik, I. Dincer, Int J Green Energy, 2014, 11, 404.
There are 9 citations in total.

Details

Primary Language Turkish
Authors

İsmail Bozkurt This is me

Ayhan Atız This is me

İsmail Bozkurt This is me

Mehmet Karakılçık This is me

Mehmet Karakılçık This is me

Submission Date November 28, 2014
Publication Date November 28, 2014
IZ https://izlik.org/JA67ES86SK
Published in Issue Year 2014 Volume: 4 Issue: 1

Cite

APA Bozkurt, İ., Atız, A., Bozkurt, İ., Karakılçık, M., & Karakılçık, M. (2014). Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi. Adıyaman University Journal of Science, 4(1), 1-10. https://izlik.org/JA67ES86SK
AMA 1.Bozkurt İ, Atız A, Bozkurt İ, Karakılçık M, Karakılçık M. Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi. ADYU J SCI. 2014;4(1):1-10. https://izlik.org/JA67ES86SK
Chicago Bozkurt, İsmail, Ayhan Atız, İsmail Bozkurt, Mehmet Karakılçık, and Mehmet Karakılçık. 2014. “Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi”. Adıyaman University Journal of Science 4 (1): 1-10. https://izlik.org/JA67ES86SK.
EndNote Bozkurt İ, Atız A, Bozkurt İ, Karakılçık M, Karakılçık M (June 1, 2014) Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi. Adıyaman University Journal of Science 4 1 1–10.
IEEE [1]İ. Bozkurt, A. Atız, İ. Bozkurt, M. Karakılçık, and M. Karakılçık, “Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi”, ADYU J SCI, vol. 4, no. 1, pp. 1–10, June 2014, [Online]. Available: https://izlik.org/JA67ES86SK
ISNAD Bozkurt, İsmail - Atız, Ayhan - Bozkurt, İsmail - Karakılçık, Mehmet - Karakılçık, Mehmet. “Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi”. Adıyaman University Journal of Science 4/1 (June 1, 2014): 1-10. https://izlik.org/JA67ES86SK.
JAMA 1.Bozkurt İ, Atız A, Bozkurt İ, Karakılçık M, Karakılçık M. Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi. ADYU J SCI. 2014;4:1–10.
MLA Bozkurt, İsmail, et al. “Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi”. Adıyaman University Journal of Science, vol. 4, no. 1, June 2014, pp. 1-10, https://izlik.org/JA67ES86SK.
Vancouver 1.İsmail Bozkurt, Ayhan Atız, İsmail Bozkurt, Mehmet Karakılçık, Mehmet Karakılçık. Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi. ADYU J SCI [Internet]. 2014 Jun. 1;4(1):1-10. Available from: https://izlik.org/JA67ES86SK

...