The aim of this study was to analyse comparatively the estimation methods of bioclimatic comfort in poultry houses and to describe the mean radiant temperature.
The inside (Ti) and mean radiant (MRT1 , MRT2 , MRT3) temperatures in , uninsulated poultry house (h2) were found higher than adequately insulated poultry house (h1) between 12-6 p.m. (P< 0.05; P< 0.01).
For the determination of bioclimatic comfort in adequately insulated poultry houses only inside dry-bulb and wet-bulb air temperatures and enthalpy should be used. In uninsulated poultry house, in addition to inside dry.-bulb and wet-bulb air temperatures and enthalpy, inside surface temperatures should be taken into account and mean radiant temperatures (MRT1, MRT2) «estimation methods should be employed.
Araştırma, kümeslerde biyoklimatik rahatlığı belirleme yöntemlerinin karşılaştırmalı analizi ve ortalama radyant sıcaklığın tanımlanması amacı ile yapılmıştır.
Kümes içi (Ti) ve ortalama radyant (MRT1 , MRT2, MRT3).sıcaklıklar yapı elemanları yalıtımı yetersiz olan kümeste (h2), yapı elenları yalıtımı yeterli sayılan kümes'e (h1) oranla saat 12:00- 18:00 arasında daha yüksek bulunmuştur (P <0.05; P< 0.01).X
Kümeslerde biyoklimatik rahatlığın belirlenmesinde, yapı elemanları .yalıtımı yeterli olduğunda yalnızca iç havanın kuru-ıslak termometre sıcaklıkları ve antalpi ölçüt olarak alınmalı, yapı elemanları yalıtımı yetersiz olduğunda ise, iç havanın kuru-ıslak termometre sıcaklıklarına ve antalpisine ek olarak yapı elemanları iç yüzey sıcaklıkları da ölçüt olarak alınmalı ve ortalama radyant sıcaklık (MRT1, MRT2) belirleme yöntemleri kullanılmalıdır.
Primary Language | English |
---|---|
Subjects | Agricultural Engineering |
Journal Section | Articles |
Authors | |
Publication Date | December 1, 1990 |
Published in Issue | Year 1990 Volume: 3 Issue: 1-2 |