Research Article
BibTex RIS Cite
Year 2009, Volume: 3 Issue: 1, 40 - 44, 01.10.2009
https://doi.org/10.2399/ana.09.009

Abstract

A study on evaluation of 3D virtual rabbit kidney models by multidetector computed tomography images

Year 2009, Volume: 3 Issue: 1, 40 - 44, 01.10.2009
https://doi.org/10.2399/ana.09.009

Abstract

Objectives: This study was performed to reveal biometric peculiarities of New Zealand rabbit kidneys by means of threedimensional (3D) reconstruction of multidetector computed tomography (MDCT) images.

Methods: Under general anaesthesia, the kidneys of eight rabbits of both sexes were scanned by high resolution imaging using a general diagnostic MDCT. The thoracic and lumbar vertebrae of the rabbit were used as reference structure to locate exact position of the kidneys in the rabbit body. Finally, landmarks of the kidneys were identified and labelled in the MDCT images and then 3D models were formed to analyse the locations, dimensions and volumes of the kidneys with respect to the vertebral column in transparently modelled body.

Results: The left and right kidney volumes are 9153.3 mm3 and 9761 mm3 respectively. The right kidney is approximately 9% longer, 22% wider and 27% thicker than the left kidney. The left kidney is 16% flatter than the right one.

Conclusion: The authors have proposed that the 3D reconstructed results of the MDCT images can contribute to the anatomical education and clinical applications.

There are 0 citations in total.

Details

Primary Language English
Subjects Health Care Administration
Journal Section Articles
Authors

Emrullah Eken This is me

Özşen Çorumluoğlu This is me

Yahya Paksoy This is me

Kamil Beşoluk This is me

İbrahim Kalaycı This is me

Publication Date October 1, 2009
Published in Issue Year 2009 Volume: 3 Issue: 1

Cite

APA Eken, E., Çorumluoğlu, Ö., Paksoy, Y., Beşoluk, K., et al. (2009). A study on evaluation of 3D virtual rabbit kidney models by multidetector computed tomography images. Anatomy, 3(1), 40-44. https://doi.org/10.2399/ana.09.009
AMA Eken E, Çorumluoğlu Ö, Paksoy Y, Beşoluk K, Kalaycı İ. A study on evaluation of 3D virtual rabbit kidney models by multidetector computed tomography images. Anatomy. October 2009;3(1):40-44. doi:10.2399/ana.09.009
Chicago Eken, Emrullah, Özşen Çorumluoğlu, Yahya Paksoy, Kamil Beşoluk, and İbrahim Kalaycı. “A Study on Evaluation of 3D Virtual Rabbit Kidney Models by Multidetector Computed Tomography Images”. Anatomy 3, no. 1 (October 2009): 40-44. https://doi.org/10.2399/ana.09.009.
EndNote Eken E, Çorumluoğlu Ö, Paksoy Y, Beşoluk K, Kalaycı İ (October 1, 2009) A study on evaluation of 3D virtual rabbit kidney models by multidetector computed tomography images. Anatomy 3 1 40–44.
IEEE E. Eken, Ö. Çorumluoğlu, Y. Paksoy, K. Beşoluk, and İ. Kalaycı, “A study on evaluation of 3D virtual rabbit kidney models by multidetector computed tomography images”, Anatomy, vol. 3, no. 1, pp. 40–44, 2009, doi: 10.2399/ana.09.009.
ISNAD Eken, Emrullah et al. “A Study on Evaluation of 3D Virtual Rabbit Kidney Models by Multidetector Computed Tomography Images”. Anatomy 3/1 (October 2009), 40-44. https://doi.org/10.2399/ana.09.009.
JAMA Eken E, Çorumluoğlu Ö, Paksoy Y, Beşoluk K, Kalaycı İ. A study on evaluation of 3D virtual rabbit kidney models by multidetector computed tomography images. Anatomy. 2009;3:40–44.
MLA Eken, Emrullah et al. “A Study on Evaluation of 3D Virtual Rabbit Kidney Models by Multidetector Computed Tomography Images”. Anatomy, vol. 3, no. 1, 2009, pp. 40-44, doi:10.2399/ana.09.009.
Vancouver Eken E, Çorumluoğlu Ö, Paksoy Y, Beşoluk K, Kalaycı İ. A study on evaluation of 3D virtual rabbit kidney models by multidetector computed tomography images. Anatomy. 2009;3(1):40-4.

Anatomy is the official journal of Turkish Society of Anatomy and Clinical Anatomy (TSACA).