The use of dacron synthetic ligament prosthesis in the reconstruction of anterior cruciate ligament

Volume: 25 Number: 5 September 11, 2006
  • Ethem Gur
  • Mustafa Basbozkurt
  • Metin Baydar
  • N. Ertur
EN TR

The use of dacron synthetic ligament prosthesis in the reconstruction of anterior cruciate ligament

Abstract

Dacron ligament prosthesis was applied to 33 cases for chronic ACL instability, in our department. We used four different techniques; only dacron ligament. preparation with iliotibial band, dacron ligament prosthesis application with anterior transfer of m. sartorius with combination of pes plasty procedures, the application of dacron ligament like Mac Intosh technique Lysholm score was preoperatively 24-64, postoperatively a''erage 91. Tegner activity score was preoperatively 3-10 and postoperatively at least 4. We believe that dacron ligament prosthesis is useful in ACL reconstruction without important complications.

Keywords

Details

Primary Language

English

Subjects

-

Journal Section

-

Authors

Ethem Gur This is me

Mustafa Basbozkurt This is me

Metin Baydar This is me

N. Ertur This is me

Publication Date

September 11, 2006

Submission Date

March 6, 2014

Acceptance Date

-

Published in Issue

Year 1991 Volume: 25 Number: 5

APA
Gur, E., Basbozkurt, M., Baydar, M., & Ertur, N. (2006). The use of dacron synthetic ligament prosthesis in the reconstruction of anterior cruciate ligament. Acta Orthopaedica et Traumatologica Turcica, 25(5), 380-384. https://doi.org/10.3944/aott.v25i5.1269
AMA
1.Gur E, Basbozkurt M, Baydar M, Ertur N. The use of dacron synthetic ligament prosthesis in the reconstruction of anterior cruciate ligament. Acta Orthopaedica et Traumatologica Turcica. 2006;25(5):380-384. doi:10.3944/aott.v25i5.1269
Chicago
Gur, Ethem, Mustafa Basbozkurt, Metin Baydar, and N. Ertur. 2006. “The Use of Dacron Synthetic Ligament Prosthesis in the Reconstruction of Anterior Cruciate Ligament”. Acta Orthopaedica et Traumatologica Turcica 25 (5): 380-84. https://doi.org/10.3944/aott.v25i5.1269.
EndNote
Gur E, Basbozkurt M, Baydar M, Ertur N (September 1, 2006) The use of dacron synthetic ligament prosthesis in the reconstruction of anterior cruciate ligament. Acta Orthopaedica et Traumatologica Turcica 25 5 380–384.
IEEE
[1]E. Gur, M. Basbozkurt, M. Baydar, and N. Ertur, “The use of dacron synthetic ligament prosthesis in the reconstruction of anterior cruciate ligament”, Acta Orthopaedica et Traumatologica Turcica, vol. 25, no. 5, pp. 380–384, Sept. 2006, doi: 10.3944/aott.v25i5.1269.
ISNAD
Gur, Ethem - Basbozkurt, Mustafa - Baydar, Metin - Ertur, N. “The Use of Dacron Synthetic Ligament Prosthesis in the Reconstruction of Anterior Cruciate Ligament”. Acta Orthopaedica et Traumatologica Turcica 25/5 (September 1, 2006): 380-384. https://doi.org/10.3944/aott.v25i5.1269.
JAMA
1.Gur E, Basbozkurt M, Baydar M, Ertur N. The use of dacron synthetic ligament prosthesis in the reconstruction of anterior cruciate ligament. Acta Orthopaedica et Traumatologica Turcica. 2006;25:380–384.
MLA
Gur, Ethem, et al. “The Use of Dacron Synthetic Ligament Prosthesis in the Reconstruction of Anterior Cruciate Ligament”. Acta Orthopaedica et Traumatologica Turcica, vol. 25, no. 5, Sept. 2006, pp. 380-4, doi:10.3944/aott.v25i5.1269.
Vancouver
1.Ethem Gur, Mustafa Basbozkurt, Metin Baydar, N. Ertur. The use of dacron synthetic ligament prosthesis in the reconstruction of anterior cruciate ligament. Acta Orthopaedica et Traumatologica Turcica. 2006 Sep. 1;25(5):380-4. doi:10.3944/aott.v25i5.1269