Muscle strength after ACL reconstruction with bone tendon-bone patellar autograft tested by Cybex II dynamometer

Volume: 28 Number: 5 September 11, 2006
  • Abdullah Gogus
  • Omer Taser
  • Levent Eralp
EN TR

Muscle strength after ACL reconstruction with bone tendon-bone patellar autograft tested by Cybex II dynamometer

Abstract

The Cybex II dynamometer is a device which offers isokinetic testing of different body joints and muscle groups, allowing precise, reproducible control of joint range of motion in keeping with specific rehabilitation goals. This system collects torque, work and power data, thus it can be used to identify and quantify functional musculoskeletal deficits. 25 patients with chronic anterolateral knee instability have been treated with ACL reconstruction using bone-tendon-bone patellar autograft and early aggressive rehabilitation program. As well known, the most common complications of the above mentioned procedure are chondromalacia patellae, loss in ROM, and failure to gain quadriceps strength. All patients have been tested on the involved and uninvolved sides. The results for the velocity 180deg/sec are: peak torque in flex. inv./uninv.-%114, total work in flex. inv./uninv.-%117, peak torque in extan.inv./ uninv.-%90, total work in extan. inv./uninv.-%80. These results confirm that this operative method and our rehabilitation program offer good results regarding muscle strength

Keywords

Details

Primary Language

English

Subjects

-

Journal Section

-

Authors

Abdullah Gogus This is me

Omer Taser This is me

Levent Eralp This is me

Publication Date

September 11, 2006

Submission Date

March 6, 2014

Acceptance Date

-

Published in Issue

Year 1994 Volume: 28 Number: 5

APA
Gogus, A., Taser, O., & Eralp, L. (2006). Muscle strength after ACL reconstruction with bone tendon-bone patellar autograft tested by Cybex II dynamometer. Acta Orthopaedica et Traumatologica Turcica, 28(5), 324-327. https://doi.org/10.3944/aott.v28i5.1518
AMA
1.Gogus A, Taser O, Eralp L. Muscle strength after ACL reconstruction with bone tendon-bone patellar autograft tested by Cybex II dynamometer. Acta Orthopaedica et Traumatologica Turcica. 2006;28(5):324-327. doi:10.3944/aott.v28i5.1518
Chicago
Gogus, Abdullah, Omer Taser, and Levent Eralp. 2006. “Muscle Strength After ACL Reconstruction With Bone Tendon-Bone Patellar Autograft Tested by Cybex II Dynamometer”. Acta Orthopaedica et Traumatologica Turcica 28 (5): 324-27. https://doi.org/10.3944/aott.v28i5.1518.
EndNote
Gogus A, Taser O, Eralp L (September 1, 2006) Muscle strength after ACL reconstruction with bone tendon-bone patellar autograft tested by Cybex II dynamometer. Acta Orthopaedica et Traumatologica Turcica 28 5 324–327.
IEEE
[1]A. Gogus, O. Taser, and L. Eralp, “Muscle strength after ACL reconstruction with bone tendon-bone patellar autograft tested by Cybex II dynamometer”, Acta Orthopaedica et Traumatologica Turcica, vol. 28, no. 5, pp. 324–327, Sept. 2006, doi: 10.3944/aott.v28i5.1518.
ISNAD
Gogus, Abdullah - Taser, Omer - Eralp, Levent. “Muscle Strength After ACL Reconstruction With Bone Tendon-Bone Patellar Autograft Tested by Cybex II Dynamometer”. Acta Orthopaedica et Traumatologica Turcica 28/5 (September 1, 2006): 324-327. https://doi.org/10.3944/aott.v28i5.1518.
JAMA
1.Gogus A, Taser O, Eralp L. Muscle strength after ACL reconstruction with bone tendon-bone patellar autograft tested by Cybex II dynamometer. Acta Orthopaedica et Traumatologica Turcica. 2006;28:324–327.
MLA
Gogus, Abdullah, et al. “Muscle Strength After ACL Reconstruction With Bone Tendon-Bone Patellar Autograft Tested by Cybex II Dynamometer”. Acta Orthopaedica et Traumatologica Turcica, vol. 28, no. 5, Sept. 2006, pp. 324-7, doi:10.3944/aott.v28i5.1518.
Vancouver
1.Abdullah Gogus, Omer Taser, Levent Eralp. Muscle strength after ACL reconstruction with bone tendon-bone patellar autograft tested by Cybex II dynamometer. Acta Orthopaedica et Traumatologica Turcica. 2006 Sep. 1;28(5):324-7. doi:10.3944/aott.v28i5.1518