Experience in Surface Replacement Arthroplasty (Wagner) in Osteoarthrosis of the Hip Joint

Volume: 15 Number: 3 August 10, 1981
  • M. Yucel
EN TR

Experience in Surface Replacement Arthroplasty (Wagner) in Osteoarthrosis of the Hip Joint

Abstract

The report describes 42 double cup endoprothesis of the hip (Wagner-cup) at an overage age 53,5 years. The procedure was mainly indicated in osteoarthrosis caused by dysplasia coxae, genuine osteoarthrosis of the hip joint. Joint surface substitution represents a very interesting surgical method in which, unlike in the case of total endoprothetic substitution the physiological state of the joint is preserved. However, technically, this is very difficult operation, which requires a great deal of skill. Most authors reporting of resutts published to date do not give sufficient information on late results, and the present publicalion is no exception. The author will be in a position to give an assessment only in a few years time. According to the authors experience, hip joint endoprothesis after Wagner is in many instances an enrichment of the alternative techniques available for dealing with coxarthrosis and it has shifted the position of total endoprothesis from the indication list.

Keywords

Details

Primary Language

English

Subjects

-

Journal Section

-

Authors

M. Yucel This is me

Publication Date

August 10, 1981

Submission Date

March 7, 2014

Acceptance Date

-

Published in Issue

Year 1981 Volume: 15 Number: 3

APA
Yucel, M. (1981). Experience in Surface Replacement Arthroplasty (Wagner) in Osteoarthrosis of the Hip Joint. Acta Orthopaedica et Traumatologica Turcica, 15(3), 172-184. https://doi.org/10.3944/aott.v15i3.3178
AMA
1.Yucel M. Experience in Surface Replacement Arthroplasty (Wagner) in Osteoarthrosis of the Hip Joint. Acta Orthopaedica et Traumatologica Turcica. 1981;15(3):172-184. doi:10.3944/aott.v15i3.3178
Chicago
Yucel, M. 1981. “Experience in Surface Replacement Arthroplasty (Wagner) in Osteoarthrosis of the Hip Joint”. Acta Orthopaedica et Traumatologica Turcica 15 (3): 172-84. https://doi.org/10.3944/aott.v15i3.3178.
EndNote
Yucel M (August 1, 1981) Experience in Surface Replacement Arthroplasty (Wagner) in Osteoarthrosis of the Hip Joint. Acta Orthopaedica et Traumatologica Turcica 15 3 172–184.
IEEE
[1]M. Yucel, “Experience in Surface Replacement Arthroplasty (Wagner) in Osteoarthrosis of the Hip Joint”, Acta Orthopaedica et Traumatologica Turcica, vol. 15, no. 3, pp. 172–184, Aug. 1981, doi: 10.3944/aott.v15i3.3178.
ISNAD
Yucel, M. “Experience in Surface Replacement Arthroplasty (Wagner) in Osteoarthrosis of the Hip Joint”. Acta Orthopaedica et Traumatologica Turcica 15/3 (August 1, 1981): 172-184. https://doi.org/10.3944/aott.v15i3.3178.
JAMA
1.Yucel M. Experience in Surface Replacement Arthroplasty (Wagner) in Osteoarthrosis of the Hip Joint. Acta Orthopaedica et Traumatologica Turcica. 1981;15:172–184.
MLA
Yucel, M. “Experience in Surface Replacement Arthroplasty (Wagner) in Osteoarthrosis of the Hip Joint”. Acta Orthopaedica et Traumatologica Turcica, vol. 15, no. 3, Aug. 1981, pp. 172-84, doi:10.3944/aott.v15i3.3178.
Vancouver
1.M. Yucel. Experience in Surface Replacement Arthroplasty (Wagner) in Osteoarthrosis of the Hip Joint. Acta Orthopaedica et Traumatologica Turcica. 1981 Aug. 1;15(3):172-84. doi:10.3944/aott.v15i3.3178