BibTex RIS Cite

Biomechanical features of internal fixation methods in tibial fractures

Year 1989, Volume: 23 Issue: 3, 134 - 136, 11.09.2006

Abstract

25 fresh cedaver tibias were used for biomechanical testing of different internal fixation methods in tibial fractures. 45 degree oblique fractures were created in the middle 1/3 of the diaphyses. 1O tibias were tested for intramedullary Ender nailing, 8 for intramedullary Kuntscher nailing, 7 for plate-screw fixation. Test specimens were subjected to axial compression, lateral bending and torsional forces. Plate osteosynthesis was found to be the most resistant to compression forces and Kuntscher and Ender nailing followed. As for bending, Kuntscher nailing was the most reliable and then came plate fixation and Ender nailing. For torsional stresses, the order was plate osteosynthesis, Ender and Kuntscher nailing. Ender nails were elastic and the deformation disappeared as the forces were removed. This was an advantage for Ender nails.

Tibia kırıklarında farklı internal tesbit materyallerinin biomekanik özellikleri

Year 1989, Volume: 23 Issue: 3, 134 - 136, 11.09.2006

Abstract

Tibia cisim kırıklarında farklı internal tesbit materyallerinin biomekanik özellikleri 25 taze kadavra tibiası kullanılarak araştırıldı. Bu amaç ile tibianın 113 orta kısmından 45°'lik açıda yapay oblik bir kırık oluşturuldu. 10 tibiaya intramedüller Ender, 8 tibiaya intramedüller Kuntscher civisi, 7 tibiaya ise plaklı osteosentez uygulandı. Test örnekleri INSTRON 1114 test makinasında aksial kompresyon, lateral eğilmeye ve Torque makinasında burulma deneylerine tabi tutuldular. Deneyler sonucunda kompresyona en fazla plaklı osteosentezin dayandığı, bunu Küntscher çivisinin ve en düşük düzeyde de Ender çivisinin izlediği görüldü. Eğilmeye en fazla Küntscher çivisinin dayandığı, bunu plaklı osteosentezin izlediği, Ender çivisinin de pIaklı osteosenteze yakın sonuçlar verdiği saptandı. Buna karşın burulmaya en fazla plaklı osteosentezin dayandığı, bunu Ender çivisinin izIediği, en düşük düzeyde de Küntscher çivisinin bulunduğu görüldü. Ender çivilerinin yetmezlikten önceki yükler altında elastiki bir stabilite gösterdiği ve mevcut deformasyonun, yükün kalkması ile düzeldiği tesbit edildi. Bu özellik Ender çivileri için bir avantaj kabul ediIdi.

There are 0 citations in total.

Details

Primary Language English
Journal Section Experimental Study
Authors

Emin Alici This is me

Erdogan Kutluay This is me

Publication Date September 11, 2006
Published in Issue Year 1989 Volume: 23 Issue: 3

Cite

APA Alici, E., & Kutluay, E. (2006). Biomechanical features of internal fixation methods in tibial fractures. Acta Orthopaedica Et Traumatologica Turcica, 23(3), 134-136. https://doi.org/10.3944/aott.v23i3.1062
AMA Alici E, Kutluay E. Biomechanical features of internal fixation methods in tibial fractures. Acta Orthopaedica et Traumatologica Turcica. September 2006;23(3):134-136. doi:10.3944/aott.v23i3.1062
Chicago Alici, Emin, and Erdogan Kutluay. “Biomechanical Features of Internal Fixation Methods in Tibial Fractures”. Acta Orthopaedica Et Traumatologica Turcica 23, no. 3 (September 2006): 134-36. https://doi.org/10.3944/aott.v23i3.1062.
EndNote Alici E, Kutluay E (September 1, 2006) Biomechanical features of internal fixation methods in tibial fractures. Acta Orthopaedica et Traumatologica Turcica 23 3 134–136.
IEEE E. Alici and E. Kutluay, “Biomechanical features of internal fixation methods in tibial fractures”, Acta Orthopaedica et Traumatologica Turcica, vol. 23, no. 3, pp. 134–136, 2006, doi: 10.3944/aott.v23i3.1062.
ISNAD Alici, Emin - Kutluay, Erdogan. “Biomechanical Features of Internal Fixation Methods in Tibial Fractures”. Acta Orthopaedica et Traumatologica Turcica 23/3 (September 2006), 134-136. https://doi.org/10.3944/aott.v23i3.1062.
JAMA Alici E, Kutluay E. Biomechanical features of internal fixation methods in tibial fractures. Acta Orthopaedica et Traumatologica Turcica. 2006;23:134–136.
MLA Alici, Emin and Erdogan Kutluay. “Biomechanical Features of Internal Fixation Methods in Tibial Fractures”. Acta Orthopaedica Et Traumatologica Turcica, vol. 23, no. 3, 2006, pp. 134-6, doi:10.3944/aott.v23i3.1062.
Vancouver Alici E, Kutluay E. Biomechanical features of internal fixation methods in tibial fractures. Acta Orthopaedica et Traumatologica Turcica. 2006;23(3):134-6.