Torsional strenght of graft removed long bones

Year 1989, Volume: 23 Issue: 3, 137 - 140, 11.09.2006

Abstract

It s important to know decreasing the torsional strength of graft removed bones which is frequently use for bone grafting. In this experimental and biomechanial research it is animed determining the maximum torqua force and energy to find the maximum area and shape of graft in secur limits. Circular and rectangular cortical grafts were removed from the right tibiae of 80 pairs of sheep bones. The area of the grafts were one cm2 and one and half cm2 Each pairs were broken comparingly by applying torque force. Sudden and strong torsional fractures were preferred because loading configuration effects to every section alongs its length and similar is encountered in clinical fraclures.
In experiment, the standard test machine of Burstein and Frankel's principles were used. The curve of maximum torque and degree for the fractures were obtained electronically and the results were digitalised by the computer. Torsional strength of the bones were compared with the contralateral samples. Average torsional strength loss are 11.28 (Nm) (%51.5) and 12.65 (Nm) (%60.2) for rectangular graft, removing with one, and one and half square centimeters. Subsequently, the values of 4.51 (Nm) (%19.66) and 4.71 (Nm) (%20.96) are measured as an average differences for the circular shape grafts removing with the same areas. The decrease of strength less in circular grafts.

Greft alınan uzun kemiklerin torsiyonel dirençleri

Year 1989, Volume: 23 Issue: 3, 137 - 140, 11.09.2006

Abstract

Greft alınan tibianın torsiyonel direncinin ne kadar azaldığının araştırılması amacı ile bu deneysel biomekanik calışma yapılmıştır. 80 cift koyun tibiasının sağ teklerinden kare ve daire şeklinde 1 ve 1.5 cm2'lik greftler çıkarılmıştır. Bu kemikler sol tekleri ile karşılaştırmalı olarak kırılmıştır. Darbeli torsiyonel kırma, kemiği bütün uzun ekseni boyunca etkileyebilmesi ve klinik kırılmaya benzer bir kırık oluşturduğu için tercih edilmiştir. Deneyde Burstein ve Frankel'in geliştirdiği düzeneğin benzeri kullanılmış ve yüklemede aynı prensipler uyguIanmıştır. Maksimum kırılma torku (Nm) ve açı (derece) büyüklükleri elektronik olarak algılanıp, grafik üzerine kaydedilmiş ve bilgisayarla digitalize edilerek değerIendirilmiştir.
Greft aIınması geneI oIarak tibianın buruIma kapasitesinde azalmaya neden olmaktadır. Bu azalma 1 ve 1.5 cm2 greftlerde sağlam karşıtlarına oranla sırasıyla 11.28 (Nm) (Yüzde 51.5) ve 12.65 (Nm)(Yüzde 60-25) düzeyindedir. Aynı büyükIükte daire şeklindeki greftlerin yol açtığı azalma ise ortalama 4.51 (Nm) (Yüzde 19.66) ve 4.71 (Nm) (Yüzde 20.96) kadar olup, kemiğin burulma dayanımını daha az etkilemektedir.

There are 0 citations in total.

Details

Primary Language English
Journal Section Experimental Study
Authors

Halit Ozyalcin This is me

Erhan Sesli This is me

Unal Evcim This is me

Gurbuz Celebi This is me

Publication Date September 11, 2006
Published in Issue Year 1989 Volume: 23 Issue: 3

Cite

APA Ozyalcin, H., Sesli, E., Evcim, U., Celebi, G. (2006). Torsional strenght of graft removed long bones. Acta Orthopaedica Et Traumatologica Turcica, 23(3), 137-140. https://doi.org/10.3944/aott.v23i3.1063
AMA Ozyalcin H, Sesli E, Evcim U, Celebi G. Torsional strenght of graft removed long bones. Acta Orthopaedica et Traumatologica Turcica. September 2006;23(3):137-140. doi:10.3944/aott.v23i3.1063
Chicago Ozyalcin, Halit, Erhan Sesli, Unal Evcim, and Gurbuz Celebi. “Torsional Strenght of Graft Removed Long Bones”. Acta Orthopaedica Et Traumatologica Turcica 23, no. 3 (September 2006): 137-40. https://doi.org/10.3944/aott.v23i3.1063.
EndNote Ozyalcin H, Sesli E, Evcim U, Celebi G (September 1, 2006) Torsional strenght of graft removed long bones. Acta Orthopaedica et Traumatologica Turcica 23 3 137–140.
IEEE H. Ozyalcin, E. Sesli, U. Evcim, and G. Celebi, “Torsional strenght of graft removed long bones”, Acta Orthopaedica et Traumatologica Turcica, vol. 23, no. 3, pp. 137–140, 2006, doi: 10.3944/aott.v23i3.1063.
ISNAD Ozyalcin, Halit et al. “Torsional Strenght of Graft Removed Long Bones”. Acta Orthopaedica et Traumatologica Turcica 23/3 (September 2006), 137-140. https://doi.org/10.3944/aott.v23i3.1063.
JAMA Ozyalcin H, Sesli E, Evcim U, Celebi G. Torsional strenght of graft removed long bones. Acta Orthopaedica et Traumatologica Turcica. 2006;23:137–140.
MLA Ozyalcin, Halit et al. “Torsional Strenght of Graft Removed Long Bones”. Acta Orthopaedica Et Traumatologica Turcica, vol. 23, no. 3, 2006, pp. 137-40, doi:10.3944/aott.v23i3.1063.
Vancouver Ozyalcin H, Sesli E, Evcim U, Celebi G. Torsional strenght of graft removed long bones. Acta Orthopaedica et Traumatologica Turcica. 2006;23(3):137-40.