Abstract

Eleven patient with ten ununited fractures and one congenital pseudoarthrasis of tibia were teraeted. Exclusively with pulsating electromagnetic field in two plan. The over all success rate in healing of the fracture with this surgicully non-invasive out patient method was 81.8 percent. The success rate was not materially effected by the age or sex of the patient. the lenght of prior disablity, the number rf previous failed operations or the presence of infection or bulky methalic fixation.

Kaynamayan kırıkların elektromagnetik alanla tedavisi

Year 1987, Volume: 21 Issue: 5, 188 - 192, 11.08.2006

Abstract

Ankara Üniversitesi Tıp Fakültesi Ortopedi ve Travmatoloji Anabilim Dalında 11 nonunion gösteren kırık elektromagnetik alanla tedavi edildi. Cerrahi olmayan bu tip konservatif tedavi metoduyla %81.8 başarı sağlandı. Bu başarı oranı hastanın yaşı, cinsi veya sakatlık süresinin uzunluğu, daha önce geçirdiği amaleyatların sayısı veya mevcut enfeksiyon veya metabolik fiksasyonla bir ilgisi yoktur.

There are 0 citations in total.

Details

Primary Language English
Journal Section Original Article
Authors

Gungor Cakirgil This is me

Rasit Cesur This is me

Sinan Adiyaman This is me

Mehmet Demirtas This is me

Cihangir Islam This is me

Publication Date August 11, 2006
Published in Issue Year 1987 Volume: 21 Issue: 5

Cite

APA Cakirgil, G., Cesur, R., Adiyaman, S., Demirtas, M., et al. (2006). Treatment Of Ununited Tibial Diaphyseal Fractures With Electromagnetic Fields. Acta Orthopaedica Et Traumatologica Turcica, 21(5), 188-192. https://doi.org/10.3944/aott.v21i5.2654
AMA Cakirgil G, Cesur R, Adiyaman S, Demirtas M, Islam C. Treatment Of Ununited Tibial Diaphyseal Fractures With Electromagnetic Fields. Acta Orthopaedica et Traumatologica Turcica. August 2006;21(5):188-192. doi:10.3944/aott.v21i5.2654
Chicago Cakirgil, Gungor, Rasit Cesur, Sinan Adiyaman, Mehmet Demirtas, and Cihangir Islam. “Treatment Of Ununited Tibial Diaphyseal Fractures With Electromagnetic Fields”. Acta Orthopaedica Et Traumatologica Turcica 21, no. 5 (August 2006): 188-92. https://doi.org/10.3944/aott.v21i5.2654.
EndNote Cakirgil G, Cesur R, Adiyaman S, Demirtas M, Islam C (August 1, 2006) Treatment Of Ununited Tibial Diaphyseal Fractures With Electromagnetic Fields. Acta Orthopaedica et Traumatologica Turcica 21 5 188–192.
IEEE G. Cakirgil, R. Cesur, S. Adiyaman, M. Demirtas, and C. Islam, “Treatment Of Ununited Tibial Diaphyseal Fractures With Electromagnetic Fields”, Acta Orthopaedica et Traumatologica Turcica, vol. 21, no. 5, pp. 188–192, 2006, doi: 10.3944/aott.v21i5.2654.
ISNAD Cakirgil, Gungor et al. “Treatment Of Ununited Tibial Diaphyseal Fractures With Electromagnetic Fields”. Acta Orthopaedica et Traumatologica Turcica 21/5 (August 2006), 188-192. https://doi.org/10.3944/aott.v21i5.2654.
JAMA Cakirgil G, Cesur R, Adiyaman S, Demirtas M, Islam C. Treatment Of Ununited Tibial Diaphyseal Fractures With Electromagnetic Fields. Acta Orthopaedica et Traumatologica Turcica. 2006;21:188–192.
MLA Cakirgil, Gungor et al. “Treatment Of Ununited Tibial Diaphyseal Fractures With Electromagnetic Fields”. Acta Orthopaedica Et Traumatologica Turcica, vol. 21, no. 5, 2006, pp. 188-92, doi:10.3944/aott.v21i5.2654.
Vancouver Cakirgil G, Cesur R, Adiyaman S, Demirtas M, Islam C. Treatment Of Ununited Tibial Diaphyseal Fractures With Electromagnetic Fields. Acta Orthopaedica et Traumatologica Turcica. 2006;21(5):188-92.