Abstract

A total endoprastheses of the hip, whether it is loosened early or late, confrants the orthopaedists who employ surgical applications with as great problems today as they had previously. The results of an experimental study are presented, while mention is made of the causes of probable loosening in femoral shaft prostheserq attention is drawn here to the relation between the length of the stem of the prosthesis and the optimal connection of this stem with the intramedullary cavity.

Endoprotez gevşemelerinde biyolojik mekanik sorunlar

Year 1985, Volume: 19 Issue: 4, 329 - 345, 27.11.1985

Abstract

Gerek erken, gerekse geç olarak gevşemiş bir kalça total endoprotezi, eskiden olduğu gibi bugün de cerrahi uygulamalar yapan ortopedistleri büyük sorunlar karşısında bırakmaktadır. Femur şaftı protezlerinin olabilecek gevşeme nedenleri dile getirilirken deneysel bir çalışmanın sonuçları sunulmaktadır. Burada protez sapının uzunluğu ile bu sapın ilik boşluğundaki optimal bağlantılanması arasında bir ilinti bulunmaktadır.

There are 0 citations in total.

Details

Primary Language English
Journal Section Experimental Study
Authors

Kemal Erol This is me

Publication Date November 27, 1985
Published in Issue Year 1985 Volume: 19 Issue: 4

Cite

APA Erol, K. (1985). Biologic mechanical problems in the loosening of endoprastheses. Acta Orthopaedica Et Traumatologica Turcica, 19(4), 329-345. https://doi.org/10.3944/aott.v19i4.3026
AMA Erol K. Biologic mechanical problems in the loosening of endoprastheses. Acta Orthopaedica et Traumatologica Turcica. November 1985;19(4):329-345. doi:10.3944/aott.v19i4.3026
Chicago Erol, Kemal. “Biologic Mechanical Problems in the Loosening of Endoprastheses”. Acta Orthopaedica Et Traumatologica Turcica 19, no. 4 (November 1985): 329-45. https://doi.org/10.3944/aott.v19i4.3026.
EndNote Erol K (November 1, 1985) Biologic mechanical problems in the loosening of endoprastheses. Acta Orthopaedica et Traumatologica Turcica 19 4 329–345.
IEEE K. Erol, “Biologic mechanical problems in the loosening of endoprastheses”, Acta Orthopaedica et Traumatologica Turcica, vol. 19, no. 4, pp. 329–345, 1985, doi: 10.3944/aott.v19i4.3026.
ISNAD Erol, Kemal. “Biologic Mechanical Problems in the Loosening of Endoprastheses”. Acta Orthopaedica et Traumatologica Turcica 19/4 (November 1985), 329-345. https://doi.org/10.3944/aott.v19i4.3026.
JAMA Erol K. Biologic mechanical problems in the loosening of endoprastheses. Acta Orthopaedica et Traumatologica Turcica. 1985;19:329–345.
MLA Erol, Kemal. “Biologic Mechanical Problems in the Loosening of Endoprastheses”. Acta Orthopaedica Et Traumatologica Turcica, vol. 19, no. 4, 1985, pp. 329-45, doi:10.3944/aott.v19i4.3026.
Vancouver Erol K. Biologic mechanical problems in the loosening of endoprastheses. Acta Orthopaedica et Traumatologica Turcica. 1985;19(4):329-45.