Fracture of fhe femoral component of total hip prosthesis is mostly seen on the stem of the femoral component. Common cause of fracture due to failure of fhe operation and prosthesis material. In this presented case, stem and head of the prosthesis were produced from different material and these parts were connected with simple weld and prosthesis was broken place of the weld. We have never detected this type of fracture in the literature.
Femoral endoprotezlerde kınk büyük sıklıkla sapta meydana gelmektedir. Kırık sebeplerinin başında endoprotezin yerleştirilmesindeki teknik hatalar ve protezin imal edildiği alaşımın özellikleri gelmektedir. Takdim ettiğimiz olguda total kalça protezinin femoral komponentinin baş ve sap kısmı ayrı ayrı alaşımlardan yapılıp kaynak ile birleştirilmiş ve protez bu kaynak yerinden kırılmıştır.
Bilsel, N., Er, T., Guney, N., Yalniz, E. (1984). THE FRACTURE OF THE FEMORAL COMPONENT DUE TO SUTRUCTURAL ERRORS FOLLOWING OPERATION OF TOTAL HIP PROSTHESIS. Acta Orthopaedica Et Traumatologica Turcica, 18(2), 90-99. https://doi.org/10.3944/aott.v18i2.3070
AMA
Bilsel N, Er T, Guney N, Yalniz E. THE FRACTURE OF THE FEMORAL COMPONENT DUE TO SUTRUCTURAL ERRORS FOLLOWING OPERATION OF TOTAL HIP PROSTHESIS. Acta Orthopaedica et Traumatologica Turcica. May 1984;18(2):90-99. doi:10.3944/aott.v18i2.3070
Chicago
Bilsel, Nafiz, Turgay Er, Nejat Guney, and Erol Yalniz. “THE FRACTURE OF THE FEMORAL COMPONENT DUE TO SUTRUCTURAL ERRORS FOLLOWING OPERATION OF TOTAL HIP PROSTHESIS”. Acta Orthopaedica Et Traumatologica Turcica 18, no. 2 (May 1984): 90-99. https://doi.org/10.3944/aott.v18i2.3070.
EndNote
Bilsel N, Er T, Guney N, Yalniz E (May 1, 1984) THE FRACTURE OF THE FEMORAL COMPONENT DUE TO SUTRUCTURAL ERRORS FOLLOWING OPERATION OF TOTAL HIP PROSTHESIS. Acta Orthopaedica et Traumatologica Turcica 18 2 90–99.
IEEE
N. Bilsel, T. Er, N. Guney, and E. Yalniz, “THE FRACTURE OF THE FEMORAL COMPONENT DUE TO SUTRUCTURAL ERRORS FOLLOWING OPERATION OF TOTAL HIP PROSTHESIS”, Acta Orthopaedica et Traumatologica Turcica, vol. 18, no. 2, pp. 90–99, 1984, doi: 10.3944/aott.v18i2.3070.
ISNAD
Bilsel, Nafiz et al. “THE FRACTURE OF THE FEMORAL COMPONENT DUE TO SUTRUCTURAL ERRORS FOLLOWING OPERATION OF TOTAL HIP PROSTHESIS”. Acta Orthopaedica et Traumatologica Turcica 18/2 (May 1984), 90-99. https://doi.org/10.3944/aott.v18i2.3070.
JAMA
Bilsel N, Er T, Guney N, Yalniz E. THE FRACTURE OF THE FEMORAL COMPONENT DUE TO SUTRUCTURAL ERRORS FOLLOWING OPERATION OF TOTAL HIP PROSTHESIS. Acta Orthopaedica et Traumatologica Turcica. 1984;18:90–99.
MLA
Bilsel, Nafiz et al. “THE FRACTURE OF THE FEMORAL COMPONENT DUE TO SUTRUCTURAL ERRORS FOLLOWING OPERATION OF TOTAL HIP PROSTHESIS”. Acta Orthopaedica Et Traumatologica Turcica, vol. 18, no. 2, 1984, pp. 90-99, doi:10.3944/aott.v18i2.3070.
Vancouver
Bilsel N, Er T, Guney N, Yalniz E. THE FRACTURE OF THE FEMORAL COMPONENT DUE TO SUTRUCTURAL ERRORS FOLLOWING OPERATION OF TOTAL HIP PROSTHESIS. Acta Orthopaedica et Traumatologica Turcica. 1984;18(2):90-9.