BibTex RIS Cite

False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture

Year 1980, Volume: 14 Issue: 4, 195 - 199, 21.11.1980

Abstract

A case of false aneurysm of the profunda femoris artery caused by an excessively long screw used to fix a CHS-plate to the neck of the femur is presented. The aneurysm did not become symptomatic until 20 days after insertion of the screw if painful pulsating mass appears in the upper part of the thigh after an operation about the hip in which drills ond screw were used, one should suspect a false aneurysm.

FEMUR BOYUN KIRIĞININ İNTERNAL FİKSASYONU (CTS-Plate İle) SONUCU OLUŞAN ARTERİA FEMORALİS PROFUNDANIN YALANCI ANEVRİZMASI

Year 1980, Volume: 14 Issue: 4, 195 - 199, 21.11.1980

Abstract

Kliniğimizde tedavi edilen bir fernur boyun kırığı olgusunda ortaya çıkan arteria femoralis profundanın yalancı anevrizması takdim edilmektedir. Çok nadir görülen bu komplikasyon kliniğimizde ilk defa gözlenmiş ve hastaya gerekli tedavi yapılarak şifa ile sonuçlanmıştır.

There are 0 citations in total.

Details

Primary Language English
Journal Section Case Report
Authors

Sukru Arac This is me

Yaser Musdal This is me

Publication Date November 21, 1980
Published in Issue Year 1980 Volume: 14 Issue: 4

Cite

APA Arac, S., & Musdal, Y. (1980). False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture. Acta Orthopaedica Et Traumatologica Turcica, 14(4), 195-199. https://doi.org/10.3944/aott.v14i4.3229
AMA Arac S, Musdal Y. False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture. Acta Orthopaedica et Traumatologica Turcica. November 1980;14(4):195-199. doi:10.3944/aott.v14i4.3229
Chicago Arac, Sukru, and Yaser Musdal. “False Aneurysm of the Profunda Femoris Artery Resulting from Internal Fixation (CHS-Plate) of a Femoral Neck Fracture”. Acta Orthopaedica Et Traumatologica Turcica 14, no. 4 (November 1980): 195-99. https://doi.org/10.3944/aott.v14i4.3229.
EndNote Arac S, Musdal Y (November 1, 1980) False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture. Acta Orthopaedica et Traumatologica Turcica 14 4 195–199.
IEEE S. Arac and Y. Musdal, “False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture”, Acta Orthopaedica et Traumatologica Turcica, vol. 14, no. 4, pp. 195–199, 1980, doi: 10.3944/aott.v14i4.3229.
ISNAD Arac, Sukru - Musdal, Yaser. “False Aneurysm of the Profunda Femoris Artery Resulting from Internal Fixation (CHS-Plate) of a Femoral Neck Fracture”. Acta Orthopaedica et Traumatologica Turcica 14/4 (November 1980), 195-199. https://doi.org/10.3944/aott.v14i4.3229.
JAMA Arac S, Musdal Y. False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture. Acta Orthopaedica et Traumatologica Turcica. 1980;14:195–199.
MLA Arac, Sukru and Yaser Musdal. “False Aneurysm of the Profunda Femoris Artery Resulting from Internal Fixation (CHS-Plate) of a Femoral Neck Fracture”. Acta Orthopaedica Et Traumatologica Turcica, vol. 14, no. 4, 1980, pp. 195-9, doi:10.3944/aott.v14i4.3229.
Vancouver Arac S, Musdal Y. False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture. Acta Orthopaedica et Traumatologica Turcica. 1980;14(4):195-9.