ROBUST REFRACTIVE INDEX FIBER SENSOR BASED ON TWO UP-TAPERS PLACED IN DOWN-TAPER
Abstract
In this study, a novel tapered optical fiber sensor based on a Mach–Zehnder interferometer (MZI) for refractive index measurement is proposed. Our sensor is constructed with two up-tapers symmetrically placed in a down-taper single mode fiber. Although its waist diameter is as thick as 55 μm, the sensor can measure the refractive index. Simulation results demonstrate RI sensitivities of -94 nm/RIU and -125 nm/RIU at the lower and higher wavelength of the spectrum. The sensor is extremely robust, it can be easily manufactured and it can be used not only for RI but also for simultaneous strain and temperature measurements.
Keywords
References
- Ji, W. B., Liu, H. H., Tjin, S. C., Chow, K. K. and Lim, A., Ultrahigh sensitivity refractive index sensor based on optical microfiber, IEEE Phot. Tech. Lett., 24 (2012) 1872-1874.
- Lacroix, S., Gonthier, F., Black R. J., and Bures, J., Tapered-fiber interferometric wavelength response: the achromatic fringe, Opt. Lett., 13 (1988) 395-397.
- Bariáin, C., Matías, I.R., Arregui, F. J. and López-Amo, M., Tapered optical-fiber-based pressure sensor, Opt. Eng., 39 (2000) 2241-2247.
- Massaro, A., Spano, F., Missori, M., Malvindi, M. A., Cazzato, P., Cingolani, R. and Athanassiou, A., Flexible nanocomposites with all-optical tactile sensing capability, RSC Adv., 4, (2014) 2820-2825.
- Lu, P., Men, L., Sooley, K. and Chen, Q., Tapered fiber Mach–Zehnder interferometer for simultaneous measurement of refractive index and temperature, Appl. Phys. Lett., 94, (2009) 131110-131110-(3).
- Shao, L-Y., Zhao, J., Dong, X., Tam, H. Y., Lu, C. and He, S., Long-period grating fabricated by periodically tapering standard single-mode fiber, App. Optics, 47 (2007) 1549-1552.
- Bariáin, C., Matías, I. R., Fernández-Valdivielso, C., Arregui, F. J., Rodríguez-Méndez, M. L. and Saja, J. A., Optical fiber sensor based on lutetium bisphthalocyanine for the detection of gases using standard telecommunication wavelengths, Sens. Act. B Chem., 93 (2003) 153-158.
- Corres, J. M., Matías, I. R., Bravo, J. and Arregui, F. J., Tapered optical fiber biosensor for the detection of anti-gliadin antibodies, Sens. Act. B, Chem., 135 (2008) 166-171.
Details
Primary Language
English
Subjects
Engineering
Journal Section
Research Article
Publication Date
December 1, 2019
Submission Date
July 18, 2019
Acceptance Date
October 11, 2019
Published in Issue
Year 1970 Volume: 61 Number: 2
