Research Article

Geant4 based dosimetry evaluation for gamma knife using different phantom materials

Volume: 63 Number: 2 December 30, 2021
EN

Geant4 based dosimetry evaluation for gamma knife using different phantom materials

Abstract

This study examines the dose difference for a variety of phantom materials that can be employed for “Leksell Gamma” Knifes. These materials resemble human tissue by not including the skull bone. Geant4 was utilized in the analysis of the dose distributions for collimator helmet sizes of 4mm and 8mm. The phantom is illustrated with a radius of 80mm. Water, brain, Poly-methyl methacrylate (PMMA) and polystyrene were being considered as the main material types. Results proved that there is no considerable differences for radiation dosimetries depending on the material types. In addition, the polystyrene and PMMA (phantom is also quite appropriate in terms of evaluating the dose profiles of the Gamma Knife unit.

Keywords

References

  1. Bertolino, N., Experimental validation of Monte Carlo simulation of Leksell Gamma Knife Perfexion stereotactic radiosurgery system. PhD Thesis, Università Degli Studi Di Milano, (2009), 6-17.
  2. Goetsch, S.J., Risk analysis of Leksell Gamma Knife Model C with automatic positioning system, Int. J. Radiat. Oncol. Biol. Phys., 52 (2002), 869-877. https://doi.org/:10.1016/s0360-3016(01)02718-3
  3. Leksell Gamma Plan Instructions for Use for Version 4.0-Target Series, Elekta, 1996.
  4. Ekinci, F., Bostanci, E., Dagli, O., Guzel, M.S., Analysis of Bragg curve parameters and lateral straggle for proton and carbon beams, Commun. Fac. Sci. Univ. Ank. Ser. A2-A3, 63 (1) (2021), 32-41. https://doi.org/:10.33769/aupse.864475
  5. Dagli, O., Bostanci, E., Emmez, O.H., Ekinci, F., Celtikci, E., A statistical analysis of the effect of different embolization materials on Gamma Knife arteriovenous malformation dose distributions, arXiv:2101.08034 (2021). https://arxiv.org/abs/2101.08034
  6. Ekinci, F., Bostanci, E., Dagli, O., Guzel, M.S., Recoil analysis for heavy ion beams, arXiv:2101.09720 (2021). https://arxiv.org/abs/2101.09720
  7. ICRU Report 62 Prescribing, Recording and Reporting Photo Beam Therapy (Supplement to ICRU Report 50), Bethesda, (1999).
  8. Aksoy, A., Karsli, O., Aydin, A., Kaya, C., Ketenoglu, B., Ketenoglu, D. and Yavas, O. Current status of Turkish accelerator and radiation laboratory in Ankara: the TARLA facility, Can. J. Phys., 96 (7) (2018), 837-842. https://doi.org/10.1139/cjp-2017-0750

Details

Primary Language

English

Subjects

Engineering

Journal Section

Research Article

Publication Date

December 30, 2021

Submission Date

June 23, 2021

Acceptance Date

October 13, 2021

Published in Issue

Year 1970 Volume: 63 Number: 2

APA
Dağlı, Ö., Bostancı, G. E., Emmez, H., Kurt, G., Ekinci, F., & Güzel, M. S. (2021). Geant4 based dosimetry evaluation for gamma knife using different phantom materials. Communications Faculty of Sciences University of Ankara Series A2-A3 Physical Sciences and Engineering, 63(2), 118-126. https://doi.org/10.33769/aupse.956400
AMA
1.Dağlı Ö, Bostancı GE, Emmez H, Kurt G, Ekinci F, Güzel MS. Geant4 based dosimetry evaluation for gamma knife using different phantom materials. Commun.Fac.Sci.Univ.Ank.Series A2-A3: Phys.Sci. and Eng. 2021;63(2):118-126. doi:10.33769/aupse.956400
Chicago
Dağlı, Özlem, Gazi Erkan Bostancı, Hakan Emmez, Gökhan Kurt, Fatih Ekinci, and Mehmet Serdar Güzel. 2021. “Geant4 Based Dosimetry Evaluation for Gamma Knife Using Different Phantom Materials”. Communications Faculty of Sciences University of Ankara Series A2-A3 Physical Sciences and Engineering 63 (2): 118-26. https://doi.org/10.33769/aupse.956400.
EndNote
Dağlı Ö, Bostancı GE, Emmez H, Kurt G, Ekinci F, Güzel MS (December 1, 2021) Geant4 based dosimetry evaluation for gamma knife using different phantom materials. Communications Faculty of Sciences University of Ankara Series A2-A3 Physical Sciences and Engineering 63 2 118–126.
IEEE
[1]Ö. Dağlı, G. E. Bostancı, H. Emmez, G. Kurt, F. Ekinci, and M. S. Güzel, “Geant4 based dosimetry evaluation for gamma knife using different phantom materials”, Commun.Fac.Sci.Univ.Ank.Series A2-A3: Phys.Sci. and Eng., vol. 63, no. 2, pp. 118–126, Dec. 2021, doi: 10.33769/aupse.956400.
ISNAD
Dağlı, Özlem - Bostancı, Gazi Erkan - Emmez, Hakan - Kurt, Gökhan - Ekinci, Fatih - Güzel, Mehmet Serdar. “Geant4 Based Dosimetry Evaluation for Gamma Knife Using Different Phantom Materials”. Communications Faculty of Sciences University of Ankara Series A2-A3 Physical Sciences and Engineering 63/2 (December 1, 2021): 118-126. https://doi.org/10.33769/aupse.956400.
JAMA
1.Dağlı Ö, Bostancı GE, Emmez H, Kurt G, Ekinci F, Güzel MS. Geant4 based dosimetry evaluation for gamma knife using different phantom materials. Commun.Fac.Sci.Univ.Ank.Series A2-A3: Phys.Sci. and Eng. 2021;63:118–126.
MLA
Dağlı, Özlem, et al. “Geant4 Based Dosimetry Evaluation for Gamma Knife Using Different Phantom Materials”. Communications Faculty of Sciences University of Ankara Series A2-A3 Physical Sciences and Engineering, vol. 63, no. 2, Dec. 2021, pp. 118-26, doi:10.33769/aupse.956400.
Vancouver
1.Özlem Dağlı, Gazi Erkan Bostancı, Hakan Emmez, Gökhan Kurt, Fatih Ekinci, Mehmet Serdar Güzel. Geant4 based dosimetry evaluation for gamma knife using different phantom materials. Commun.Fac.Sci.Univ.Ank.Series A2-A3: Phys.Sci. and Eng. 2021 Dec. 1;63(2):118-26. doi:10.33769/aupse.956400

Communications Faculty of Sciences University of Ankara Series A2-A3 Physical Sciences and Engineering licensed under a Creative Commons Attribution 4.0 International License.

Creative Commons License