Research Article
BibTex RIS Cite

The Diagnostic Value of Serum Reduction Activity and Redox Dye Tests in Malignant Neoplastic Diseases

Year 1950, Volume: 4 Issue: 1-2, 151 - 162, 31.12.1950
https://izlik.org/JA96SG94TD

Abstract

This study investigates the diagnostic value of measuring serum reduction activity in malignant neoplastic diseases. Using redox dyes such as methylene blue and brilliant cresyl blue, the tests revealed a significant prolongation of reduction time in malignant cases. Comparative analysis with normal and non-neoplastic subjects indicated that conditions like hypoproteinemia and hyperlipidemia may also influence reduction time. A decrease in serum sulfhydryl groups was found to reduce reduction capacity. Although these tests are not sufficiently specific for early diagnosis, they may serve as useful adjuncts in clinical evaluation.

Ethical Statement

-

Supporting Institution

-

Project Number

-

Thanks

-

References

  • Sehrt, E. (1929). Eine neue Methode der Sauerstoffbestimmung des menschlichen Blutes mittels Indophenolblau. Krebsforschung, 30, 260–270.
  • Savignag, R. J., Grant, J. C., & Sizer, I. W. (1944). Reducing Properties of Serum from Nonmalignant Patients and from Normal Individuals. Research Conference on Cancer, pp. 241–258.
  • Stern, K., & Willheim, R. (1943). The Biochemistry of Malignant Tumors. Brooklyn, NY: Reference Press, pp. 287–291.
  • Black, M. M. (1941). Changes in the Reducing Power of Serum of Patients with Malignant Neoplastic Disease. Cancer Research, 7, 321–325.
  • Black, M. M. (1947). Sulfhydryl Reduction of Methylene Blue: With Reference to Alteration in Malignant Neoplastic Disease. Cancer Research, 7, 592–594.
  • Black, M. M. (1948). Observations presented at the 4th International Congress on Cancer Research, Saint Louis. Ars Medici, 3(4), April.

Malign Neoplastik Hastalıkların Diyagnozunda Serumun Redüksiyon Aktivitesinin Değeri ve Redoks Boya Testleri

Year 1950, Volume: 4 Issue: 1-2, 151 - 162, 31.12.1950
https://izlik.org/JA96SG94TD

Abstract

Bu çalışma, malign neoplastik hastalıkların tanısında serumun redüksiyon aktivitesinin ölçülmesinin değerini araştırmaktadır. Metilen mavisi ve brilliant cresyl blue gibi redoks boyalar kullanılarak yapılan testlerde, malign hastalıklarda redüksiyon zamanının belirgin şekilde uzadığı gözlenmiştir. Normal ve non-neoplastik vakalarla karşılaştırmalı olarak yapılan analizlerde, hipoproteinemi ve hiperlipemi gibi durumların da redüksiyon süresini etkileyebileceği belirtilmiştir. Ayrıca serumdaki sulfhydryl gruplarının azalması, redüksiyon kapasitesinin düşmesine neden olabilmektedir. Bu testlerin erken tanı için yeterince spesifik olmadığı, ancak yardımcı tanı aracı olarak faydalı olabileceği sonucuna varılmıştır.

Project Number

-

References

  • Sehrt, E. (1929). Eine neue Methode der Sauerstoffbestimmung des menschlichen Blutes mittels Indophenolblau. Krebsforschung, 30, 260–270.
  • Savignag, R. J., Grant, J. C., & Sizer, I. W. (1944). Reducing Properties of Serum from Nonmalignant Patients and from Normal Individuals. Research Conference on Cancer, pp. 241–258.
  • Stern, K., & Willheim, R. (1943). The Biochemistry of Malignant Tumors. Brooklyn, NY: Reference Press, pp. 287–291.
  • Black, M. M. (1941). Changes in the Reducing Power of Serum of Patients with Malignant Neoplastic Disease. Cancer Research, 7, 321–325.
  • Black, M. M. (1947). Sulfhydryl Reduction of Methylene Blue: With Reference to Alteration in Malignant Neoplastic Disease. Cancer Research, 7, 592–594.
  • Black, M. M. (1948). Observations presented at the 4th International Congress on Cancer Research, Saint Louis. Ars Medici, 3(4), April.
There are 6 citations in total.

Details

Primary Language Turkish
Subjects ​Internal Diseases
Journal Section Research Article
Authors

İrfan Titiz This is me

Project Number -
Publication Date December 31, 1950
IZ https://izlik.org/JA96SG94TD
Published in Issue Year 1950 Volume: 4 Issue: 1-2

Cite

APA Titiz, İ. (1950). Malign Neoplastik Hastalıkların Diyagnozunda Serumun Redüksiyon Aktivitesinin Değeri ve Redoks Boya Testleri. Ankara Üniversitesi Tıp Fakültesi Mecmuası, 4(1-2), 151-162. https://izlik.org/JA96SG94TD
AMA 1.Titiz İ. Malign Neoplastik Hastalıkların Diyagnozunda Serumun Redüksiyon Aktivitesinin Değeri ve Redoks Boya Testleri. Ankara Üniversitesi Tıp Fakültesi Mecmuası. 1950;4(1-2):151-162. https://izlik.org/JA96SG94TD
Chicago Titiz, İrfan. 1950. “Malign Neoplastik Hastalıkların Diyagnozunda Serumun Redüksiyon Aktivitesinin Değeri Ve Redoks Boya Testleri”. Ankara Üniversitesi Tıp Fakültesi Mecmuası 4 (1-2): 151-62. https://izlik.org/JA96SG94TD.
EndNote Titiz İ (December 1, 1950) Malign Neoplastik Hastalıkların Diyagnozunda Serumun Redüksiyon Aktivitesinin Değeri ve Redoks Boya Testleri. Ankara Üniversitesi Tıp Fakültesi Mecmuası 4 1-2 151–162.
IEEE [1]İ. Titiz, “Malign Neoplastik Hastalıkların Diyagnozunda Serumun Redüksiyon Aktivitesinin Değeri ve Redoks Boya Testleri”, Ankara Üniversitesi Tıp Fakültesi Mecmuası, vol. 4, no. 1-2, pp. 151–162, Dec. 1950, [Online]. Available: https://izlik.org/JA96SG94TD
ISNAD Titiz, İrfan. “Malign Neoplastik Hastalıkların Diyagnozunda Serumun Redüksiyon Aktivitesinin Değeri Ve Redoks Boya Testleri”. Ankara Üniversitesi Tıp Fakültesi Mecmuası 4/1-2 (December 1, 1950): 151-162. https://izlik.org/JA96SG94TD.
JAMA 1.Titiz İ. Malign Neoplastik Hastalıkların Diyagnozunda Serumun Redüksiyon Aktivitesinin Değeri ve Redoks Boya Testleri. Ankara Üniversitesi Tıp Fakültesi Mecmuası. 1950;4:151–162.
MLA Titiz, İrfan. “Malign Neoplastik Hastalıkların Diyagnozunda Serumun Redüksiyon Aktivitesinin Değeri Ve Redoks Boya Testleri”. Ankara Üniversitesi Tıp Fakültesi Mecmuası, vol. 4, no. 1-2, Dec. 1950, pp. 151-62, https://izlik.org/JA96SG94TD.
Vancouver 1.Titiz İ. Malign Neoplastik Hastalıkların Diyagnozunda Serumun Redüksiyon Aktivitesinin Değeri ve Redoks Boya Testleri. Ankara Üniversitesi Tıp Fakültesi Mecmuası [Internet]. 1950 Dec. 1;4(1-2):151-62. Available from: https://izlik.org/JA96SG94TD